Skip to main content

Schneider-Electric
TM200C24R

controller M200 24 IO relay
Net discounted price 218.55 EUR
Available when ordered (delivery time: 36 working day(s))
Barcode: 3606480696053
Tariff code: 8537109199

Link to the manufacturers site: TM200C24R - controller M200 24 IO relay

Main

Range of produc: Easy Modicon M200

Product or component type: Logic controller

[Us] rated supply voltage: 100...240 V AC

Discrete I/O number: 24

Discrete input number: I2...I5: 4 fast input; I0, I1, I6, I7: 4 high speed input; I8...I13: 6 regular input

Discrete output number: 10 relay

Discrete input voltage: 24 V

discrete input voltage type: DC

Discrete input current: 7 mA for input

Discrete input logic: Sink or source (positive/negative) type 1 conforming to IEC 61131-2

Discrete output voltage: 24 V DC; 220 V AC

Discrete output current: 2 A

Discrete output type: Relay normally open

Power consumption in VA: 52…64 VA at 100...240 V AC (with max I/O)

Complementary

Maximum number of I/O expansion module: 4 with 128 discrete output(s) for transistor output; 4 with 74 discrete output(s) for relay output

Supply voltage limits: 85…264 V

Network frequency: 50/60 Hz

Inrush current: 50 A

Voltage state 1 guaranteed: >= 15 V for input

Voltage state 0 guaranteed: <= 5 V for input

Input impedance: 3.3 kOhm for discrete input

Response time: 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input; 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input; 100 µs turn-off, I2...I5 terminal(s) for fast input; 35 µs turn-on, I2...I5 terminal(s) for fast input; 10 ms turn-off, Q0...Q9 terminal(s) for relay output; 10 ms turn-on, Q0...Q9 terminal(s) for relay output; 100 µs turn-off, I8...I13 terminal(s) for regular input; 35 µs turn-on, I8...I13 terminal(s) for regular input

Configurable filtering time: 0 ms for input; 3 ms for input; 12 ms for input

Output voltage limits: 30 V DC; 250 V AC

Maximum current per output common: 4 A at COM 2; 4 A at COM 0; 4 A at COM 1

Electrical durability: 100000 cycles AC-12, 240 V, 480 VA, resistive; 100000 cycles DC-12, 24 V, 48 W, resistive

Switching frequency: 0.1 Hz with maximum load

Mechanical durability: 20000000 cycles for relay output

Minimum load: 10 mA at 5 V DC for relay output

Memory capacity: 512 byte internal flash for backup of programs

Data storage equipment: 32 GB micro SD card (optional)

Battery type: BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s)

Backup time: 3 years at 25 °C (by interruption of power supply)

Execution time for 1 KInstruction: 0.3 ms for event and periodic task

Execution time per instruction: 0.2 µs Boolean

Exct time for event task: 60 µs response time

Clock drift: <= 90 s/month at 25 °C

Regulation loop: Adjustable PID regulator up to 14 simultaneous loops

Control signal type: Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode); Pulse/direction at 100 kHz for fast input (HSC mode); Single phase at 100 kHz for fast input (HSC mode); CW/CCW at 100 kHz for fast input (HSC mode)

Counting input number: 4 fast input (HSC mode) at 100 kHz 32 bits

Integrated connection type: USB port with mini B USB 2.0 connector; Non isolated serial link serial 1 with terminal block connector and RS485 interface ; Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface ; Isolated serial link serial 2 with terminal block connector and RS485 interface

Transmission rate: 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485; 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232; 12 Mbit/s for USB

Communication port protocol: USB port: USB - SoMachine-Network; Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network

Local signalling: 1 LED (green) for PWR; 1 LED (green) for RUN; 1 LED (red) for module error (ERR); 1 LED (green) for SD card access (SD); 1 LED (red) for BAT; 1 LED (green) for SL1; 1 LED per channel (green) for I/O state

Electrical connection: Mini B USB 2.0 connectorfor a programming terminal; removable screw terminal blockfor inputs; removable screw terminal blockfor outputs; removable screw terminal block, 4 terminal(s) for connecting the serial link1; removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply

Maximum cable distance between devices: Unshielded cable: <50 m for input; Shielded cable: <10 m for fast input; Shielded cable: <10 m for high speed input; Unshielded cable: <150 m for output

Insulation: Non-insulated between inputs; Between output and internal logic at 1780 V AC; Between output groups at 1780 V AC; Between supply and internal logic at 1780 V AC; Between input and internal logic at 500 V AC; Between fast input and internal logic at 500 V AC; Between input groups at 500 V AC

Sensor power supply: 24 V DC at 250 mA supplied by the controller

Marking: CE

Mounting support: Top hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715

height: 90 mm

Depth: 70 mm

Width: 130 mm

Net weight: 0.405 kg

Environment

IP degree of protection: IP20 with protective cover in place

product certifications: IACS E10; cULus; RCM; CSA

Standards: IEC 61010-2-201; IEC 61131-2

Electromagnetic compatibility: Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3; Magnetic field at power frequency - test level: 30 A/m conforming to IEC 61000-4-8; Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to IEC 61000-4-4; 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 0.5 kV (power lines (DC)) conforming to IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (AC)) conforming to IEC 61000-4-5; Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6; Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to IEC 55011; Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to IEC 55011; Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to IEC 55011; Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to IEC 55011; 1.2/50 µs shock waves immunity test - test level: 1 kV (relay output) conforming to IEC 61000-4-5

Shock resistance: 15 gn for 11 ms; 30 gn for 6 ms

Immunity to microbreaks: 10 ms

Vibration resistance: 3.5 mm at 5…8.4 Hz on symmetrical rail; 1 gn at 8.4…150 Hz on symmetrical rail; 3.5 mm at 5…8.7 Hz on panel mounting; 2 gn at 8.7…150 Hz on panel mounting

Relative humidity: 10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage)

Ambient air temperature for operation: 0…55 °C (horizontal installation)

Ambient air temperature for storage: -25…70 °C

Pollution degree: <= 2

Operating altitude: 0...2000 m

Storage altitude: 0…3000 m

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 9.382 cm

Package 1 Width: 13.597 cm

Package 1 Length: 14.542 cm

Package 1 Weight: 611 g

Unit Type of Package 2: S03

Number of Units in Package 2: 12

Package 2 Height: 30 cm

Package 2 Width: 30 cm

Package 2 Length: 40 cm

Package 2 Weight: 7832 g

Unit Type of Package 3: P12

Number of Units in Package 3: 288

Package 3 Height: 95 cm

Package 3 Width: 80 cm

Package 3 Length: 120 cm

Package 3 Weight: 196968 g

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1408013EN

Circularity Profile: ENVEOLI1408013EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.