Schneider-Electric
STBART0200K
Tariff code: 8536909500
Link to the manufacturers site: STBART0200K - standard analog input kit STB - 2 I - 15 bits + sign
Main
Range of produc: Modicon STB distributed I/O solution
Product or component type: Standard analog input kit
Kit composition: STBART0200 module; STBXTS1100, 6-terminal screw type connector; STBXBA1000 base; STBXTS2100, 6-terminal spring clamp connector
Analogue input type: Voltage +/- 80 mV; Temperature probe -100...+260 °C Cu 10 2, 3 or 4 wires IEC; Temperature probe -100...+450 °C Pt 100 2, 3 or 4 wires US/JIS; Temperature probe -100...+450 °C Pt 1000 2, 3 or 4 wires US/JIS; Temperature probe -200...+850 °C Pt 100 2, 3 or 4 wires IEC; Temperature probe -200...+850 °C Pt 1000 2, 3 or 4 wires IEC; Temperature probe -60...+180 °C Ni 100 2, 3 or 4 wires IEC; Temperature probe -60...+180 °C Ni 1000 2, 3 or 4 wires IEC; Thermocouple +130...+1820 °C thermocouple B; Thermocouple -200...+760 °C thermocouple J; Thermocouple -270...+1000 °C thermocouple E; Thermocouple -270...+1370 °C thermocouple K; Thermocouple -270...+400 °C thermocouple T; Thermocouple -50...+1665 °C thermocouple R; Thermocouple -50...+1665 °C thermocouple S
analogue input number: 2
analogue input resolution: 15 bits + sign
Type of filter: Single low pass input filter 25 Hz
Complementary
Absolute maximum input: +/- 7.5 V DC
Cold swapping: Yes
Hot swapping fallback: Yes for standard NIMs
Fallback status: State 0 basic NIMs; User configurable standard NIMs
Data format: EN 61131-2; IEC 61131-2
Input impedance: 10 MOhm +/- 80 mV
Maximum supply current for sensors: 100 mA per input channels
Protection type: Short-circuit protection
Absolute accuracy error: +/- 0.1 % of full scale 25 °C internal; +/- 0.15 % of full scale 25 °C external
Insulation between channels and logic bus: 1500 V for 1 minute
Addressing requirement: 1 word for cold-junction compensation; 2 input words
Product compatibility: Mounting base STBXBA1000; Power distribution module STBPDT3100/3105
[Us] rated supply voltage: 24 V DC
supply: Power distribution module
Current consumption: 30 mA at 5 V DC for logic bus
Measurement resolution: 0.01 mV voltage; 0.1 °C or 0.1 °F temperature probe; 0.1 °C or 0.1 °F thermocouple
Conversion time: 150 ms voltage 60 Hz; 170 ms voltage 50 Hz; 180 ms temperature probe 60 Hz 2 or 4 wires; 200 ms temperature probe 50 Hz 2 or 4 wires; 210 ms thermocouple with internal cold-junction compensation 60 Hz; 230 ms thermocouple with internal cold-junction compensation 50 Hz; 300 ms temperature probe 60 Hz 3 wires; 340 ms temperature probe 50 Hz 3 wires; 360 ms thermocouple with external cold-junction compensation 60 Hz; 400 ms thermocouple with external cold-junction compensation 50 Hz
Maximum wiring resistance: 20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires; 20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires; 20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires; 200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires; 200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires; 50 Ohm Cu 10 IEC/US/JIS 4 wires; 50 Ohm Ni 100 IEC/US/JIS 4 wires; 50 Ohm Pt 100 IEC/US/JIS 4 wires; 500 Ohm Ni 1000 IEC/US/JIS 4 wires; 500 Ohm Pt 1000 IEC/US/JIS 4 wires
Measurement accuracy: +/- 1 °C Ni 100 25 °C external; +/- 1 °C Ni 100 25 °C internal; +/- 1 °C Ni 1000 25 °C external; +/- 1 °C Ni 1000 25 °C internal; +/- 1 °C Pt 100 25 °C internal; +/- 1 °C Pt 1000 25 °C internal; +/- 1.75 °C thermocouple B with external cold-junction compensation 25 °C; +/- 1.75 °C thermocouple E with external cold-junction compensation 25 °C; +/- 1.75 °C thermocouple J with external cold-junction compensation 25 °C; +/- 1.75 °C thermocouple K with external cold-junction compensation 25 °C; +/- 1.75 °C thermocouple R with external cold-junction compensation 25 °C; +/- 1.75 °C thermocouple S with external cold-junction compensation 25 °C; +/- 1.75 °C thermocouple T with external cold-junction compensation 25 °C; +/- 2 °C Pt 100 25 °C external; +/- 2 °C Pt 1000 25 °C external; +/- 2.85 °C thermocouple B with external cold-junction compensation 60 °C; +/- 2.85 °C thermocouple E with external cold-junction compensation 60 °C; +/- 2.85 °C thermocouple J with external cold-junction compensation 60 °C; +/- 2.85 °C thermocouple K with external cold-junction compensation 60 °C; +/- 2.85 °C thermocouple R with external cold-junction compensation 60 °C; +/- 2.85 °C thermocouple S with external cold-junction compensation 60 °C; +/- 2.85 °C thermocouple T with external cold-junction compensation 60 °C; +/- 3.6 °C thermocouple R with internal cold-junction compensation 25 °C; +/- 4 °C Cu 10 25 °C external; +/- 4 °C Cu 10 25 °C internal; +/- 4 °C thermocouple K with internal cold-junction compensation 25 °C; +/- 4.1 °C thermocouple S with internal cold-junction compensation 25 °C; +/- 4.2 °C thermocouple R with internal cold-junction compensation 60 °C; +/- 4.4 °C thermocouple T with internal cold-junction compensation 25 °C; +/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C; +/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C; +/- 5 °C thermocouple S with internal cold-junction compensation 60 °C; +/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C; +/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C; +/- 6.4 °C thermocouple T with internal cold-junction compensation 60 °C; +/- 6.8 °C thermocouple B with internal cold-junction compensation 60 °C; +/- 6.8 °C thermocouple E with internal cold-junction compensation 60 °C; +/- 7 °C thermocouple J with internal cold-junction compensation 60 °C
Marking: CE
Overvoltage category: II
Status LED: 1 LED (green) module status (RDY); 1 LED (red) module error (ERR)
Environment
product certifications: UL; FM Class 1 Division 2; CSA; ATEX Cat 3G; C-Tick
Pollution degree: 2 conforming to IEC 60664-1
Operating altitude: <= 2000 m
IP degree of protection: IP20 conforming to IEC 61131-2 class 1
ambient air temperature for operation: 0…70 °C
Ambient air temperature for operation: 32...140 °F without derating
Ambient air temperature for storage: -40…85 °C without derating
Ambient air temperature for storage: -40...185 °F without derating
Relative humidity: 95 % at 60 °C without condensation
Vibration resistance: +/-0.35 mm at 10…58 Hz; 3 gn at 58…150 Hz on 35 x 7.5 mm symmetrical DIN rail; 5 gn at 58…150 Hz on 35 x 15 mm symmetrical DIN rail
Shock resistance: 30 gn for 11 ms conforming to IEC 88 reference 2-27
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 3.000 cm
Package 1 Width: 8.300 cm
Package 1 Length: 13.300 cm
Package 1 Weight: 136.000 g
Unit Type of Package 2: S02
Number of Units in Package 2: 42
Package 2 Height: 15.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 6.031 kg
Offer Sustainability
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins