Schneider-Electric
CAD50ED
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: CAD50ED - TeSys D control relay - 5 NO - <= 690 V - 48 V DC standard coil
Main
range: TeSys; TeSys Deca
range of product: TeSys D control relay
product name: TeSys CAD
product or component type: Control relay
device short name: CAD
contactor application: Control circuit
Complementary
utilisation category: AC-14; DC-13; AC-15
pole contact composition: 5 NO
[Ue] rated operational voltage: <= 690 V AC 25...400 Hz
control circuit type: DC standard
[Uc] control circuit voltage: 48 V DC
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
[Ith] conventional free air thermal current: 10 A (at 60 °C)
Irms rated making capacity: 140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1
[Icw] rated short-time withstand current: 100 A - 1 s; 120 A - 500 ms; 140 A - 100 ms
associated fuse rating: 10 A gG conforming to IEC 60947-5-1
[Ui] rated insulation voltage: 600 V UL certified; 600 V CSA certified; 690 V conforming to IEC 60947-5-1
mounting support: Plate; Rail
connections - terminals: Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end; Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
tightening torque: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2; 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
control circuit voltage limits: 0.1...0.25 Uc (-40…70 °C):drop-out DC; 0.7...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC
operating time: 53...72 ms coil energisation and NO closing; 16...24 ms coil de-energisation and NO opening
mechanical durability: 30 Mcycles
maximum operating rate: 180 cyc/mn
time constant: 28 ms
inrush power in W: 5.4 W (at 20 °C)
hold-in power consumption in W: 5.4 W at 20 °C
minimum switching voltage: 17 V
minimum switching current: 5 mA
non-overlap time: 1.5 ms on energisation between NC and NO contact; 1.5 ms on de-energisation between NC and NO contact
insulation resistance: > 10 MOhm
mechanical robustness: Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
height: 77 mm
width: 45 mm
depth: 93 mm
net weight: 0.58 kg
compatibility code: CAD
Environment
standards: BS 4794; EN 60947-5; IEC 60947-5-1; NF C 63-140; VDE 0660; IEC 60335-1
product certifications: UL; CSA; UKCA
IP degree of protection: IP2x front face conforming to VDE 0106
protective treatment: TH conforming to IEC 60068
ambient air temperature for operation: -40…60 °C; 60…70 °C with derating
ambient air temperature for storage: -60…80 °C
operating altitude: 0...3000 m
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
EU RoHS Directive: Compliant
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure: ENVPEP110230EN
Circularity Profile: ENVEOLI1102030EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.