Schneider-Electric
ABLS1A24050
Tariff code: 8504408390
Link to the manufacturers site: ABLS1A24050 - POWER SUPPLY 24V 5A 1PH OPTIMIZED
Main
Range of produc: Modicon Power Supply
Product or component type: Power supply
Power supply type: Regulated switch mode
Variant option: Optimized
Enclosure material: Aluminium
Input voltage: 100...240 V AC single phase; 100...240 V AC phase to phase; 140...340 V DC
Rated power in W: 120 W
Output voltage: 24 V DC
Power supply output current: 5 A
Complementary
Input voltage limits: 85...264 V AC without temperature derating; 120...375 V DC without temperature derating; 85…120 V DC with temperature derating
network frequency limits: 50…60 Hz
Earthing system: TN; TT; IT
Maximum leakage current: 1 mA 240 V AC
Input protection type: Integrated fuse (not interchangeable) 4 A; External protection (recommended) 20 A Curve C; External protection (recommended) 13 A Curve C
Inrush current: 30.0 A at 115 V; 60.0 A at 230 V
Power factor: 0.55 at 115 V AC; 0.45 at 230 V AC
Efficiency: 85 % at 115 V AC; 88 % at 230 V AC
Output voltage limits: 22...28 V
Power dissipation in W: 25 W
Current consumption: < 2.5 A 115 V AC; < 1.4 A 230 V AC; < 1.3 A 140 V DC
Response time: < 1 s
Holding time: > 20 ms 115 V AC; > 40 ms 230 V AC
Load capacitance: 8000 µF
Residual ripple: < 120 mV
Meantime between failure [MTBF]: 700000 h at 25 °C, full load conforming to SR 332
Output protection type: Against overload and short-circuits, protection technology: automatic reset; Against over temperature, protection technology: manual reset; Against overvoltage, protection technology: manual reset
Connections - terminals: Screw connection: 0.5...4 mm², (AWG 20...AWG 12) without wire end ferrule for output; Screw connection: 0.5...2.5 mm², (AWG 20...AWG 14) with wire end ferrule for output; Screw connection: 0.75...4 mm², (AWG 18...AWG 12) without wire end ferrule for input; Screw connection: 0.75...4 mm², (AWG 18...AWG 12) with wire end ferrule for input
Line and load regulation: < 0.5 % at 0 to 100 % load at 25 °C; < 1 % at full voltage range in line at 25 °C
Status LED: 1 LED (green) output voltage
Depth: 117.6 mm
height: 123.6 mm
Width: 40 mm
Net weight: 0.55 kg
Output coupling: Parallel; Serial
Mounting support: Top hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; Double-profile DIN rail
Supply: SELV conforming to IEC 60950-1; SELV conforming to IEC 60204-1; SELV conforming to IEC 60364-4-41
Dielectric strength: 3000 V AC with input to output
Service life: 10 year(s)
Overvoltage category: II
Environment
Standards: IEC 62368-1; EN/IEC 61204-3; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3; IEC 61000-6-4; IEC 61000-3-2; EN 61000-3-3; UL 62368-1; CSA C22.2 No 62368-1; UL 508; CSA C22.2 No 107.1; EN/IEC 62368-1
Product certifications: CE; CUL listed; CUL recognized; RCM; CB Scheme; EAC; KC
Operating altitude: < 5000 m
Shock resistance: 150 m/s² for 11 ms
IP degree of protection: IP20
Ambient air temperature for operation: -20…-10 °C with current derating of 2 % per °C mounting position A < 2000 m; -10…40 °C without derating mounting position A 115 V AC < 2000 m; -10…50 °C without derating mounting position A 230 V AC < 2000 m; 40…70 °C with current derating of 1.67 % per °C mounting position A 115 V AC < 2000 m; 50…70 °C with current derating of 2.5 % per °C mounting position A 230 V AC < 2000 m
Electrical shock protection class: Class I
Pollution degree: 2
Vibration resistance: 3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6; 10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6
Electromagnetic compatibility: Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2; Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2; Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3; Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3; Immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3; Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4; Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5; Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5; Immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6; Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8; Immunity to voltage dips conforming to IEC 61000-4-11; Disturbing field emission conforming to EN 55016-2-3; Limits for harmonic current emissions conforming to IEC 61000-3-2; conforming to EN 55016-1-2; conforming to EN 55016-2-1
Electromagnetic emission: Conducted emissions conforming to IEC 61000-6-3; Radiated emissions conforming to IEC 61000-6-4
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 5.000 cm
Package 1 Width: 17.500 cm
Package 1 Length: 18.000 cm
Package 1 Weight: 696.000 g
Unit Type of Package 2: S03
Number of Units in Package 2: 13
Package 2 Height: 30.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 9.468 kg
Unit Type of Package 3: P12
Number of Units in Package 3: 312
Package 3 Height: 90.000 cm
Package 3 Width: 80.000 cm
Package 3 Length: 120.000 cm
Package 3 Weight: 239.232 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP2007005EN
Circularity Profile: ENVEOLI2007005EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.