Schneider-Electric
A9MEM1590
Tariff code: 9030337000
Link to the manufacturers site: A9MEM1590 - PowerTag Energy R200 3P/3PN
Main
Range: PowerLogic
Product name: PowerTag R200
Product or component type: Energy sensor
Poles description: 3P; 3P + N
Max current: 200 A
Product specific application: Energy management; Overload alarm; Power factor; Load monitoring; Circuit monitoring
Concentrator compatibility: Acti9 PowerTag Link C; Acti9 PowerTag Link; Acti9 PowerTag Link HD; Harmony Hub; EcoStruxure Panel Server Universal; EcoStruxure Panel Server Advanced; PrismaSet Active
Range compatibility: Masterpact MasterPact MTZ switch disconnector de ; Masterpact MasterPact NW; Masterpact MasterPact NT; ComPact ComPact NS
Type of measurement: Active and reactive energy; Apparent energy; Active and reactive power; Apparent power; Current; Voltage; Power factor; Internal temperature; Frequency
Accuracy class: Class 1 active energy conforming to IEC 61557-12; Class 2 reactive energy conforming to IEC 61557-12; Class 2 apparent energy conforming to IEC 61557-12; Class 1 active power conforming to IEC 61557-12; Class 2 reactive power conforming to IEC 61557-12; Class 2 apparent power conforming to IEC 61557-12; Class 1 current conforming to IEC 61557-12; Class 0.5 voltage conforming to IEC 61557-12; Class 1 power factor conforming to IEC 61557-12; Class 0.5 frequency conforming to IEC 61557-12
Metering type: Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at total per phase; Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at partial per phase; Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at 3-phase total; Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at 3-phase partial; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at total per phase; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at partial per phase; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at 3-phase total; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at 3-phase partial; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at total per phase; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at partial per phase; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at 3-phase total; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at 3-phase partial; Active power P, P1, P2, P3; Reactive power Q, Q1, Q2, Q3; Apparent power S, S1, S2, S3; Current I1, I2, I3; Calculated neutral current; Voltage U12, U23, U31; Voltage V1N, V2N, V3N; Frequency 45...65 Hz; Power factor at per phase; Power factor at total
Mounting location: Top or bottom
mounting support: Busbar; Cables
Product destination: Switchboard
Event management: Voltage loss with measured current at voltage loss
Transmission support medium: Radio frequency 2.4…2.4835 GHz conforming to IEEE 802.15.4
Emission power: 10 mW
Complementary
Form factor: Rope
Mounting mode: Clip-on (DIN rail)
Electrical connection: Removable spring terminal block
Cable cross section: 1 rigid cable 0.2…1.5 mm² without cable end; 1 stranded cable 0.2…2.5 mm² without cable end; 1 stranded cable 0.25…1.5 mm² with cable end
Wire stripping length: 11 mm
Cable length: 1 m for sensor
Diameter: Closed: 100 mm
[Ue] rated operational voltage: 100...277 V AC, +/- 20 %, phase to neutral; 173...480 V AC, +/- 20 %, phase to phase
Network frequency: 50 Hz; 60 Hz
Power consumption in VA: 3 VA
Standards: IEC 61557-12; IEC 61010-1; ETSI EN 301 487-1; IEC 61010-2-030; IEC 61326-1; ETSI EN 300 328
9 mm pitches: 2
Height: Base unit: 105 mm
Width: Base unit: 18 mm
Depth: Base unit: 67.5 mm
Colour: White (RAL 9003)
Environment
Maximum conductor temperature: 105 °C
Quality labels: CE
Directives: 2014/53/EU - radio equipment directive
Operating altitude: 0...2000 m
ambient air temperature for operation: -25…70 °C
Ambient air temperature for storage: -40…85 °C
Overvoltage category: IV conforming to IEC 61010-1
Measurement category: Category IV conforming to IEC 61010-2-030
IP degree of protection: IP20 conforming to IEC 60529
IK degree of protection: IK05
Pollution degree: 3
Relative humidity: 0…95 % at 55 °C conforming to IEC 60721-3-3
Vibration resistance: 3M4 conforming to IEC 60721-3-3
Electromagnetic compatibility: Industrial electromagnetic environment conforming to IEC 61326-1; Radiated EMC conforming to ETSI EN 301 489-17; Electromagnetic emission conforming to IEC 62311
Environmental characteristic: Indoor use
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 8.0 cm
Package 1 Width: 17.5 cm
Package 1 Length: 20.0 cm
Package 1 Weight: 565.0 g
Unit Type of Package 2: S03
Number of Units in Package 2: 7
Package 2 Height: 30.0 cm
Package 2 Width: 30.0 cm
Package 2 Length: 40.0 cm
Package 2 Weight: 4.432 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Compliant with Exemptions
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP2007001
Circularity Profile: ENVEOLI2007001
© 2018 Alplan Kft.