Skip to main content

Schneider-Electric
8501XDO40V66

NEMA Control Relay, machine tool, 4 NO, 230/250 VDC coil
Barcode:
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: 8501XDO40V66 - NEMA Control Relay, machine tool, 4 NO, 230/250 VDC coil

Main

range of product: 8501X

relay type: Control

product or component type: Relay

[In] rated current: 10 A AC; 5 A DC

Complementary

[Uc] control circuit voltage: 230/250 V DC

control circuit voltage limits: Operational: 0.8...1.1 Uc DC

rated breaking capacity: 6 A at 120 V AC for inductive control circuit conforming to UL 508; 3 A at 240 V AC for inductive control circuit conforming to UL 508; 1.5 A at 480 V AC for inductive control circuit conforming to UL 508; 1.2 A at 600 V AC for inductive control circuit conforming to UL 508; 10 A at <= 600 V AC for resistive control circuit conforming to UL 508; 1.1 A at 125 V DC for inductive control circuit conforming to UL 508; 0.55 A at 250 V DC for inductive control circuit conforming to UL 508; 0.2 A at 301...600 V DC for inductive control circuit conforming to UL 508; 4 A at 125 V DC for resistive control circuit conforming to UL 508; 0.8 A at 250 V DC for resistive control circuit conforming to UL 508

[Icm] rated short-circuit making capacity: 60 A at: 120 V AC for inductive load control circuit conforming to UL 508; 30 A at: 240 V AC for inductive load control circuit conforming to UL 508; 15 A at: 480 V AC for inductive load control circuit conforming to UL 508; 12 A at: 600 V AC for inductive load control circuit conforming to UL 508; 10 A at: <= 600 V AC for resistive load control circuit conforming to UL 508; 1.1 A at: 125 V DC for inductive load control circuit conforming to UL 508; 0.55 A at: 250 V DC for inductive load control circuit conforming to UL 508; 0.2 A at: 301...600 V DC for inductive load control circuit conforming to UL 508; 4 A at: 125 V DC for inductive load control circuit conforming to UL 508; 0.8 A at: 250 V DC for resistive load control circuit conforming to UL 508

inrush power in W: 18 W

hold-in power consumption in W: 18 W

operating time: 37 ms - pick-up; 21 ms - drop-out

contacts type and composition: 4 NO 4 standard contact cartridges

electrical connection: Screw clamp terminals

AWG gauge: AWG 18...AWG 12 copper

tightening torque: Control circuit: 1.02…1.36 N.m - on screw terminals

mounting support: Panel

height: 90.42 mm

width: 56.64 mm

depth: 131.32 mm

Environment

ambient air temperature for operation: -40…71 °C

product certifications: CSA LR60905 class 3211 03; UL listed file E78403 CCN NKCR

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Free of Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: X

Environmental Disclosure: ENVPEP1310013EN

Circularity Profile: ENVEOLI1310013EN

© 2018 Alplan Kft.