Schneider-Electric
ATV650U40N4E

variable speed drive ATV650 - 4kW/5HP - 380...480V - IP55 - disconnect switch
Net discounted price 1,247.85 EUR
Available when ordered (delivery time: 107 working day(s))
Barcode: 3606485410500
Tariff code: 8504409590

Link to the manufacturers site: ATV650U40N4E - variable speed drive ATV650 - 4kW/5HP - 380...480V - IP55 - disconnect switch

Main

Range of product: Altivar Process ATV600

product or component type: Variable speed drive

Product specific application: Process and utilities

Device short name: ATV650

Variant: With disconnect switch

Product destination: Asynchronous motors; Synchronous motors

EMC filter: Integrated with 50 m conforming to IEC 61800-3 category C2; Integrated with 150 m conforming to IEC 61800-3 category C3

IP degree of protection: IP55 conforming to IEC 60529; IP55 conforming to IEC 61800-5-1

[Us] rated supply voltage: 380...480 V

Type of cooling: Forced convection

Supply frequency: 50...60 Hz - 5...5 %

[Us] rated supply voltage: 380...480 V - 15...10 %

Motor power kW: 3 kW (heavy duty); 4 kW (normal duty)

Motor power hp: 4 hp heavy duty; 5 hp normal duty

Line current: 6.7 A at 480 V (normal duty); 6 A at 380 V (heavy duty); 5.4 A at 480 V (heavy duty); 7.6 A at 380 V (normal duty)

Prospective line Isc: 50 kA

Apparent power: 4.5 kVA at 480 V (heavy duty); 5.6 kVA at 480 V (normal duty)

Continuous output current: 7.2 A at 4 kHz for heavy duty; 9.3 A at 4 kHz for normal duty

Asynchronous motor control profile: Constant torque standard; Optimized torque mode; Constant torque standard

Synchronous motor control profile: Synchronous reluctance motor; Permanent magnet motor

Speed drive output frequency: 0.1…500 Hz

Nominal switching frequency: 4 kHz

Switching frequency: 4...12 kHz with derating factor; 2...12 kHz adjustable

Safety function: STO (safe torque off) SIL 3

Discrete input logic: 16 preset speeds

communication port protocol: Modbus TCP; Ethernet; Modbus serial

Option card: Slot A: communication module, PROFINET; Slot A: communication module, DeviceNet; Slot A: communication module, Modbus TCP/EtherNet/IP; Slot A: communication module, CANopen daisy chain RJ45; Slot A: communication module, CANopen SUB-D 9; Slot A: communication module, CANopen screw terminals; Slot A/slot B: digital and analog I/O extension module; Slot A/slot B: output relay extension module; Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link; Communication module, BACnet MS/TP; Communication module, Ethernet Powerlink; Slot A: communication module, Profibus DP V1

Complementary

Design of frequency changer: U converter

Network frequency: 50...60 Hz

Ambient air transport temperature: -40…70 °C

Relative symmetric mains voltage tolerance: 10 %

Maximum output voltage: 480.0 V

Relative symmetric network frequency tolerance: 5 %

Maximum acceleration under shock impact (during operation): 150 m/s² at 11 ms

Permitted relative humidity (during operation): Class 3K5 according to EN 60721-3

Maximum acceleration under vibrational stress (during operation): 10 m/s² at 13...200 Hz

Nominal output power: 4.0 kW

4 quadrant operation possible: False

Permitted relative humidity (during transport): Class 2K5 according to EN 60721-3

Permitted relative humidity (during storage): Class 1K5 according to EN 60721-3

Capacity of DC link: 410.0 µF

Maximum deflection under vibratory load (during operation): 1.5 mm at 2...13 Hz

Operating element present: True

Number of HW interfaces serial TTY: 0

Power loss per device current dependent: 142.0 W

Power loss static current independent: 14.0 W

Number of output phases: 3

Maximum acceleration under vibratory load (during transport): 10 m/s² at 13...200 Hz

Number of input phases: 3

Number of inputs, potential-free: 0

Maximum deflection under vibratory load (during transport): 1.5 mm at 2...13 Hz

Brake chopper integrated: False

Maximum acceleration under shock load (during transport): 150 m/s² at 11 ms

Number of HW interfaces USB: 0

Number of HW interfaces other: 0

Optical interface present: False

Computer port: True

Supporting protocol for TCP/IP: True

Application in industrial area permitted: True

Application in domestic and commercial area permitted: False

Supporting protocol for PROFIBUS: True

Number of HW interfaces industrial Ethernet: 1

Number of inputs, bidirectional, not potential-free: 0

1 phase low current possible: False

Number of HW interfaces parallel: 0

Supporting protocol for KNX: False

Supporting protocol for ASI: False

Number of HW interfaces PROFINET: 0

Supporting protocol for CAN: True

Supporting protocol for INTERBUS: False

Supporting protocol for DeviceNet: False

Supporting protocol for SUCONET: False

Supporting protocol for LON: False

Supporting protocol for MODBUS: True

Supporting protocol for Data-Highway: False

Supporting protocol for PROFINET IO: True

Supporting protocol for PROFINET CBA: True

Maximum acceleration under shock load (during storage): 150 m/s² at 11 ms

Supporting protocol for Foundation Fieldbus: False

Supporting protocol for SERCOS: False

Maximum deflection under vibratory load (during storage): 1.5 mm at 2...13 Hz

Supporting protocol for DeviceNet Safety: False

Supporting protocol for INTERBUS-Safety: False

Supporting protocol for PROFIsafe: False

Supporting protocol for EtherNet/IP: True

Supporting protocol for AS-Interface Safety at Work: False

Maximum acceleration under vibratory load (during storage): 10 m/s² at 13...200 Hz

With safety function Safe torque off (STO): True

With sft fct Safe Stop 2 (SS2): False

With safety function Safe Stop 1 (SS1): False

Supporting protocol for SafetyBUS P: False

Supporting protocol for BACnet: False

Supporting protocol for other bus systems: False

Nominal output current: 9.3 A

With safety function Safe brake management (SBC/SBT): False

With safety function Safe Operating Stop (SOS): False

With safety function Safely Limited Position (SLP): False

With safety function Safely Limited Speed (SLS): False

With safety function Safe Speed Monitor (SSM): False

With safety function Safe Direction (SDI): False

Base load current at high overload: 7.2 A

Base load current at low overload: 9.3 A

Number of HW interfaces serial RS232: 0

With safety function Safe programmable logic: False

With safety function Safe Position (SP): False

EMC limit value (complied): True

Environmental class (during transport): Class 2C3 according to EN 60721-3-2; Class 2S1 according to EN 60721-3-2

Environmental class (during operation): Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3

Environmental class (during storage): Class 1C3 according to EN 60721-3-1; Class 1S2 according to EN 60721-3-1

Number of HW interfaces serial RS422: 0

Number of HW interfaces serial RS485: 1

Mounting mode: Wall mount

Maximum transient current: 10.2 A during 60 s (normal duty); 10.8 A during 60 s (heavy duty)

Network number of phases: 3 phases

Discrete output number: 0

Discrete output type: Relay outputs R1A, R1B, R1C 250 V AC 3000 mA; Relay outputs R1A, R1B, R1C 30 V DC 3000 mA; Relay outputs R2A, R2C 250 V AC 5000 mA; Relay outputs R2A, R2C 30 V DC 5000 mA; Relay outputs R3A, R3C 250 V AC 5000 mA; Relay outputs R3A, R3C 30 V DC 5000 mA

Output voltage: <= power supply voltage

Permissible temporary current boost: 1.5 x In during 60 s (heavy duty); 1.1 x In during 60 s (normal duty)

Motor slip compensation: Can be suppressed; Automatic whatever the load; Adjustable; Can be suppressed

Acceleration and deceleration ramps: Linear adjustable separately from 0.01...9999 s

Physical interface: Ethernet; 2-wire RS 485

Braking to standstill: By DC injection

Protection type: Safe torque off: motor; Motor phase break: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent between output phases and earth: drive; Overload of output voltage: drive; Short-circuit protection: drive; Motor phase break: drive; Overvoltages on the DC bus: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Line supply phase loss: drive; Overspeed: drive; Break on the control circuit: drive; Thermal protection: motor

Transmission rate: 10, 100 Mbits; 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps

Frequency resolution: Analog input: 0.012/50 Hz; Display unit: 0.1 Hz

Transmission frame: RTU

Electrical connection: Line side: screw terminal 4...6 mm²/AWG 12...AWG10; Motor: screw terminal 4...6 mm²/AWG 12...AWG10; Control: removable screw terminals 0.5...1.5 mm²

Connector type: RJ45 (on the remote graphic terminal) for Modbus serial; RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP

Data format: 8 bits, configurable odd, even or no parity

Type of polarization: No impedance

Exchange mode: Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP

Number of addresses: 1…247 for Modbus serial

Method of access: Slave Modbus TCP

Supply: Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection; Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection; External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection

Local signalling: 3 LEDs (dual colour) for embedded communication status; 4 LEDs (dual colour) for communication module status; 1 LED (red) for presence of voltage; 3 LEDs for local diagnostic

Width: 264 mm

Height: 678 mm

Depth: 300 mm

Net weight: 10.6 kg

Analogue input number: 3

Analogue input type: AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits; AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits

Discrete input number: 8

Discrete input type: DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)

Input compatibility: DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2; DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2

Discrete input logic: Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)

Analogue output number: 2

Analogue output type: Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits; Software-configurable current DQ-, DQ+: 30 V DC; Software-configurable current DQ-, DQ+: 100 mA

Sampling duration: 5 ms +/- 1 ms (DI5, DI6) - discrete input; 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input; 10 ms +/- 1 ms (AO1) - analog output; 2 ms +/- 0.5 ms (DI1...DI4) - discrete input

Accuracy: +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output; +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input

Linearity error: AO1, AO2: +/- 0.2 % for analog output; AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input

Relay output number: 3

Relay output type: Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles; Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles

Refresh time: Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)

Minimum switching current: Relay output R1, R2, R3: 5 mA at 24 V DC

Maximum switching current: Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC

Isolation: Between power and control terminals

Maximum output frequency: 500 kHz

Maximum associated fuse rating: 16.0 A

Maximum input current: 7.6 A

IP degree of protection: IP55

Discrete and process manufacturing: Food and beverage processing other application; Mining mineral and metal fan; Mining mineral and metal pump; Oil and gas fan; Water and waste water other application; Building - HVAC screw compressor; Food and beverage processing pump; Food and beverage processing fan; Food and beverage processing atomization; Oil and gas electro submersible pump (ESP); Oil and gas water injection pump; Oil and gas jet fuel pump; Oil and gas compressor for refinery; Water and waste water centrifuge pump; Water and waste water positive displacement pump; Water and waste water electro submersible pump (ESP); Water and waste water screw pump; Water and waste water lobe compressor; Water and waste water screw compressor; Water and waste water compressor centrifugal; Water and waste water fan; Water and waste water conveyor; Water and waste water mixer

Power range: 4…6 kW at 480…500 V 3 phases

Housing material: Plastic

Quantity per set: 1

enclosure mounting: Wall mounted

Environment

Insulation resistance: > 1 MOhm 500 V DC for 1 minute to earth

Noise level: 52 dB conforming to 86/188/EEC

Operating position: Vertical +/- 10 degree

Maximum THDI: <48 % full load conforming to IEC 61000-3-12

Electromagnetic compatibility: Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2

Pollution degree: 2 conforming to IEC 61800-5-1

Vibration resistance: 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6; 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6

Shock resistance: 15 gn for 11 ms conforming to IEC 60068-2-27

Relative humidity: 5…95 % without condensation conforming to IEC 60068-2-3

Ambient air temperature for operation: 40…50 °C (with derating factor); -15…40 °C (without derating)

Ambient air temperature for storage: -40…70 °C

Operating altitude: 1000...4800 m with current derating 1 % per 100 m; <= 1000 m without derating

Standards: IEC 61800-3; Environment 1 category C2 IEC 61800-3; Environment 2 category C3 IEC 61800-3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1

Product certifications: TÜV; UL; DNV-GL; ATEX zone 2/22; CSA; ATEX INERIS

Marking: CE

NEMA degree of protection: NEMA 1

Standards: IEC 61800-3; IEC 61800-3 environment 1 category C2; EN/IEC 61800-3 environment 2 category C3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1

Overvoltage category: III

Regulation loop: Adjustable PID regulator

Noise level: 52 dB

Pollution degree: 3

Ambient air temperature for operation: -15…50 °C

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 52.5 cm

Package 1 Width: 39 cm

Package 1 Length: 80 cm

Package 1 Weight: 13.5 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1508009EN

Circularity Profile: ENVEOLI1508009EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.