Schneider-Electric
XCSB502EX
Tariff code: 8536508090
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: XCSB502EX - metal key operated switch XCSA - NC + 2NO slow break - ATEX/IECEx
Main
Range of produc: Telemecanique Safety switches XCS
Product or component type: Safety switch
Device short name: XCSB
Material: Metal
Head type: Key operated turret head
Cable entry number: 1 tapped entry for M20 x 1.5 cable gland (included) 7…13 mm
Electrical connection: Terminal
clamping connection capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Number of poles: 3
Contacts type and composition: 1 NC + 2 NO
contact operation: Slow-break, break before make
Positive opening: With NC contact
Locking options description: With locking of actuator, unlocking by push-button
Complementary
Local signalling: Without
Mechanical durability: 600000 cycles
Minimum actuation speed: 0.01 m/s
Maximum actuation speed: 0.5 m/s
Contact code designation: A300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN/IEC 60947-5-1; A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1; Q300, DC-13 (Ue = 125 V, Ie = 0.55 A) conforming to EN/IEC 60947-5-1; Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1
[Ithe] conventional enclosed thermal current: 10 A
[Ui] rated insulation voltage: 300 V conforming to UL 508; 500 V conforming to EN/IEC 60947-1; 300 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage: 6 kV conforming to EN/IEC 60947-5-1
Short-circuit protection: 10 A cartridge fuse type gG (gl)
Actuator forcible withdrawal rtc: 1500 N
Minimum actuator force for extraction: 20 N
Maximum operating rate: 10 cyc/mn for maximum durability
body material: Zamak
Head material: Zamak
CAD overall width: 52 mm
CAD overall height: 114 mm
CAD overall depth: 44 mm
Net weight: 0.475 kg
Compatibility code: XCSB
Environment
Safety level: Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1; Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1; Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data: B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Protective treatment: TC
ambient air temperature for operation: -25…70 °C
Ambient air temperature for storage: -40…70 °C
Vibration resistance: 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance: 10 gn for 11 ms conforming to IEC 60068-2-27
Electrical shock protection class: Class I conforming to EN/IEC 60536
IP degree of protection: IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Marking: II2 D-Ex tb IIIC T85°C Db IP67
Dust zone: Zone 21 - 22
product certifications: IEC-Ex INE 17.0020X; INERIS 04ATEX0014X
Standards: EN/IEC 60079-31; EN/IEC 60079-0
Directives: 2014/34/EU - ATEX directive
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 8.8 cm
Package 1 Width: 8.5 cm
Package 1 Length: 15.2 cm
Package 1 Weight: 508.0 g
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP110614EN
Circularity Profile: N/A
© 2018 Alplan Kft.