Schneider-Electric
XCRT215EX
Tariff code: 8536508090
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: XCRT215EX - limit switch XCR - roller lever - 2 C/O - ATEX/IECEx
Main
Range of produc: OsiSense ATEX D
Series name: Special format
Product or component type: Limit switch
Product specific application: For conveyor belt shift monitoring
Device short name: XCR
Body type: Fixed
Head type: Rotary head
Material: Metal
Fixing mode: By the body
Movement of operating head: Rotary
Type of operator: Spring return roller stainless steel with lever
Switch actuation: By conveyor belt
Type of approach: Lateral approach, 2 directions
Electrical connection: Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Cable entry number: 1 tapped entry for Pg 13.5 cable gland (included) 9…12 mm
Number of poles: 2
Contacts type and composition: 2 x 1 C/O
Contacts insulation form: Za
contact operation: Snap action
Number of steps: 2
Contact block per direction [control circuit]: 1 per direction
Positive opening: With
Minimum torque for tripping: 1 N.m
Maximum actuation speed: 1.5 m/s
IP degree of protection: IP65 conforming to IEC 60529
Complementary
body material: Zinc alloy
Minimum actuation speed: 0.01 m/min
Tripping angle: 10 ° for fault signalling; 18 ° for stopping of the conveyor belt
Maximum displacement angle: -90 °; 90 °
Contact code designation: A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN 60947-5-1; A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to IEC 60947-5-1 appendix A; Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1; Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
[Ui] rated insulation voltage: 300 V conforming to UL 508; 500 V conforming to NF C 20-040 group C; 500 V (pollution degree 3) conforming to IEC 60947-1; 500 V (pollution degree 3) conforming to VDE 0110
Maximum resistance across terminals: 25 MOhm conforming to IEC 60255-7 category 3; 25 MOhm conforming to NF C 93-050 method A
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60664; 6 kV conforming to IEC 60947-1
Short-circuit protection: 10 A cartridge fuse, type gG
Electrical durability: 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <3600 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C; 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <3600 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C; 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <3600 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C
Mechanical durability: 300000 cycles
Marking: II2 D-Ex tb IIIC T85°C Db IP66/67
Width: 85 mm
height: 95 mm
Depth: 75 mm
Compatibility code: XCR
Environment
Shock resistance: 30 gn for 18 ms conforming to IEC 60068-2-27
Vibration resistance: 9 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Electrical shock protection class: Class I conforming to IEC 60536; Class I conforming to NF C 20-030
ambient air temperature for operation: -20…60 °C
Protective treatment: TC
Dust zone: Zone 21 - 22
product certifications: INERIS 04ATEX0014X; IEC-Ex INE 16.0048X
Standards: EN/IEC 60079-31; EN/IEC 60079-0
Directives: 2014/34/EU - ATEX directive
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 9.5 cm
Package 1 Width: 9.5 cm
Package 1 Length: 12.5 cm
Package 1 Weight: 1.295 kg
Unit Type of Package 2: S03
Number of Units in Package 2: 6
Package 2 Height: 30 cm
Package 2 Width: 30 cm
Package 2 Length: 40 cm
Package 2 Weight: 8.28 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP111136EN
Circularity Profile: N/A
© 2018 Alplan Kft.