Skip to main content

Schneider-Electric
XB5AT842

red Ø40 Emergency stop, switching off Ø22 latching push-pull 1NC
Net discounted price 18.11 EUR
Available when ordered (delivery time: 8 working day(s))
Barcode: 3606480623684
Tariff code: 8536508090

Link to the manufacturers site: XB5AT842 - red Ø40 Emergency stop, switching off Ø22 latching push-pull 1NC

Main

Range of produc: Harmony XB5

Product or component type: Emergency stop push-button; Emergency switching off push-button

Device short name: XB5

bezel material: Dark grey plastic

Fixing collar material: Plastic

Head type: Standard

Mounting diameter: 22 mm

Sale per indivisible quantity: 1

Shape of signaling unit head: Round

Type of operator: trigger action and mechanical latching

Reset: Push-pull

Operator profile: Red mushroom Ø 40 mm, unmarked

contact operation: Slow-break

Connections - terminals: Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1; Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1

device presentation: Complete product

Complementary

height: 43 mm

Width: 40 mm

Depth: 82 mm

Terminals description ISO n°1: (11-12)NC

Net weight: 0.065 kg

Resistance to high pressure washer: 7000000 Pa at 55 °C, distance : 0.1 m

contacts usage: Standard contacts

Positive opening: With conforming to IEC 60947-5-1 appendix K

Operating travel: 1.5 mm (NC changing electrical state); 4.3 mm (total travel)

Mechanical durability: 300000 cycles

Tightening torque: 0.8…1.2 N.m conforming to IEC 60947-1

Shape of screw head: Cross compatible with Philips no 1 screwdriver; Cross compatible with pozidriv No 1 screwdriver; Slotted compatible with flat Ø 4 mm screwdriver; Slotted compatible with flat Ø 5.5 mm screwdriver

Contacts material: Silver alloy (Ag/Ni)

Short-circuit protection: 10 A cartridge fuse type gG conforming to IEC 60947-5-1

[Ith] conventional free air thermal current: 10 A conforming to IEC 60947-5-1

[Ui] rated insulation voltage: 600 V (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-1

[Ie] rated operational current: 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1; 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1; 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1; 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1

Electrical durability: 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

Electrical reliability: Λ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to IEC 60947-5-4; Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to IEC 60947-5-4

Cap/operator or lens colour: Red

Compatibility code: XB5

Customizable: 0

customizable: No

Environment

Protective treatment: TH

Ambient air temperature for storage: -40…70 °C

ambient air temperature for operation: -40…70 °C

Overvoltage category: Class II conforming to IEC 60536

IP degree of protection: IP66 conforming to IEC 60529; IP67; IP69; IP69K

NEMA degree of protection: NEMA 13; NEMA 4X

IK degree of protection: IK03 conforming to IEC 50102

Standards: IEC 60947-5-4; IEC 60364-5-53; IEC 60204-1; ISO 13850; IEC 60947-5-1; JIS C8201-5-1; IEC 60947-1; UL 508; CSA C22.2 No 14; IEC 60947-5-5; JIS C8201-1

product certifications: CSA; DNV; BV; UL listed; GL; LROS (Lloyds register of shipping)

Vibration resistance: 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6

Shock resistance: 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27; 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 4.5 cm

Package 1 Width: 5.4 cm

Package 1 Length: 9.5 cm

Package 1 Weight: 64.0 g

Unit Type of Package 2: S02

Number of Units in Package 2: 42

Package 2 Height: 15.0 cm

Package 2 Width: 30.0 cm

Package 2 Length: 40.0 cm

Package 2 Weight: 3.127 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free: Yes

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1710010EN

Circularity Profile: ENVEOLI1710010EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.