Schneider-Electric
TM241CEC24U
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: TM241CEC24U - controller M241 24 IO transistor NPN Ethernet CAN master
Main
range of product: Modicon M241
product or component type: Logic controller
[Us] rated supply voltage: 24 V DC
discrete input number: 14, discrete input 8 fast input conforming to IEC 61131-2 Type 1
discrete output type: Transistor
discrete output number: 10 transistor 4 fast output
discrete output voltage: 24 V DC for transistor output
discrete output current: 0.5 A for transistor output (Q0...Q9); 0.1 A for fast output (PTO mode) (Q0...Q3)
Complementary
discrete I/O number: 24
maximum number of I/O expansion module: 7 (local I/O-Architecture); 14 (remote I/O-Architecture)
supply voltage limits: 20.4…28.8 V
inrush current: 50 A
power consumption in W: 32.6…40.4 W (with max number of I/O expansion module)
discrete input logic: Sink or source
discrete input voltage: 24 V
discrete input voltage type: DC
voltage state 1 guaranteed: >= 15 V for input
voltage state 0 guaranteed: <= 5 V for input
discrete input current: 5 mA for input; 10.7 mA for fast input
input impedance: 4.7 kOhm for input; 2.81 kOhm for fast input
response time: 50 µs turn-on, I0...I13 terminal(s) for input; 50 µs turn-off, I0...I13 terminal(s) for input; <= 2 µs turn-on, I0...I7 terminal(s) for fast input; <= 2 µs turn-off, I0...I7 terminal(s) for fast input; <= 34 µs turn-on, Q0...Q9 terminal(s) for output; <= 250 µs turn-off, Q0...Q9 terminal(s) for output; <= 2 µs turn-on, Q0...Q3 terminal(s) for fast output; <= 2 µs turn-off, Q0...Q3 terminal(s) for fast output
configurable filtering time: 1 µs for fast input; 12 ms for fast input; 0 ms for input; 1 ms for input; 4 ms for input; 12 ms for input
discrete output logic: Negative logic (sink)
output voltage limits: 30 V DC
maximum current per output common: 2 A with Q0...Q3 for fast output; 2 A with Q4...Q7 for output; 1 A with Q8...Q9 for output
maximum output frequency: 20 kHz for fast output (PWM mode); 100 kHz for fast output (PLS mode); 1 kHz for output
accuracy: +/- 0.1 % at 0.02…0.1 kHz for fast output; +/- 1 % at 0.1…1 kHz for fast output
maximum leakage current: 5 µA for output
maximum voltage drop: <1 V
maximum tungsten load: <2.4 W
protection type: Short-circuit protection; Short-circuit and overload protection with automatic reset; Reverse polarity protection for fast output
reset time: 10 ms automatic reset output; 12 s automatic reset fast output
memory capacity: 8 MB for program; 64 MB for system memory RAM
data backed up: 128 MB built-in flash memory for backup of user programs
data storage equipment: <= 16 GB SD card (optional)
battery type: BR2032 lithium non-rechargeable, battery life: 4 year(s)
backup time: 2 years at 25 °C
execution time for 1 KInstruction: 0.3 ms for event and periodic task; 0.7 ms for other instruction
application structure: 8 event tasks; 4 cyclic master tasks; 3 cyclic master tasks + 1 freewheeling task; 8 external event tasks
realtime clock: With
clock drift: <= 60 s/month at 25 °C
positioning functions: PTO function 4 channel(s) (positioning frequency: 100 kHz); PTO function 4 channel(s) for transistor output (positioning frequency: 1 kHz)
counting input number: 4 fast input (HSC mode) at 200 kHz; 14 standard input at 1 kHz
control signal type: A/B at 100 kHz for fast input (HSC mode); Pulse/direction at 200 kHz for fast input (HSC mode); Single phase at 200 kHz for fast input (HSC mode)
integrated connection type: Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface ; Non isolated serial link serial 2 with removable screw terminal block connector and RS485 interface ; USB port with mini B USB 2.0 connector; Ethernet with RJ45 connector; CANopen J1939 with male SUB-D 9 connector
supply: (serial 1)serial link supply: 5 V, <200 mA
transmission rate: 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485; 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232; 480 Mbit/s for bus length of 3 m for USB; 10/100 Mbit/s for Ethernet; 1000 kbit/s for bus length of 20 m for CANopen; 800 kbit/s for bus length of 40 m for CANopen; 500 kbit/s for bus length of 100 m for CANopen; 250 kbit/s for bus length of 250 m for CANopen; 125 kbit/s for bus length of 500 m for CANopen; 50 kbit/s for bus length of 1000 m for CANopen; 20 kbit/s for bus length of 2500 m for CANopen
communication port protocol: Non isolated serial link: Modbus master/slave
port Ethernet: 10BASE-T/100BASE-TX - 1 port(s) copper cable
communication service: SNMP client/server; Modbus TCP slave device; Modbus TCP server; Modbus TCP client; IEC VAR ACCESS; FTP client/server; SQL client; DHCP client; Ethernet/IP adapter; Send and receive email from the controller based on TCP/UDP library; Web server (WebVisu & XWeb system); OPC UA server; DNS client
local signalling: 1 LED (green) for PWR; 1 LED (green) for RUN; 1 LED (red) for module error (ERR); 1 LED (red) for I/O error (I/O); 1 LED (green) for SD card access (SD); 1 LED (red) for BAT; 1 LED (green) for SL1; 1 LED (green) for SL2; 1 LED (red) for bus fault on TM4 (TM4); 1 LED per channel (green) for I/O state; 1 LED (green) for Ethernet port activity; 1 LED (green) for CANopen run; 1 LED (green) for CANopen error
electrical connection: removable screw terminal blockfor inputs and outputs (pitch 5.08 mm); removable screw terminal blockfor connecting the 24 V DC power supply (pitch 5.08 mm)
maximum cable distance between devices: Unshielded cable: <50 m for input; Shielded cable: <10 m for fast input; Unshielded cable: <50 m for output; Shielded cable: <3 m for fast output
insulation: Between supply and internal logic at 500 V AC; Non-insulated between supply and ground; Between input and internal logic at 500 V AC; Non-insulated between inputs; Between fast input and internal logic at 500 V AC; Between output and internal logic at 500 V AC; Non-insulated between outputs; Between fast output and internal logic at 500 V AC
marking: CE
surge withstand: 1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5; 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5; 0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5; 1 kV relay output differential mode conforming to EN/IEC 61000-4-5; 1 kV input common mode conforming to EN/IEC 61000-4-5; 1 kV transistor output common mode conforming to EN/IEC 61000-4-5
web services: Web server
maximum number of connections: 16 Ethernet/IP device; 8 Modbus server
CANopen feature profile: DR 303-1; DS 301 V4.02
number of slave: 63 CANopen:
mounting support: Top hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit
height: 90 mm
depth: 95 mm
width: 150 mm
net weight: 0.53 kg
Environment
standards: ANSI/ISA 12-12-01; CSA C22.2 No 142; CSA C22.2 No 213; EN/IEC 61131-2:2007; Marine specification (LR, ABS, DNV, GL); UL 1604; UL 508
product certifications: RCM; IACS E10; CSA; cULus
resistance to electrostatic discharge: 8 kV in air conforming to EN/IEC 61000-4-2; 4 kV on contact conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields: 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3; 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3; 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
resistance to fast transients: 2 kV (power lines) conforming to EN/IEC 61000-4-4; 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4; 1 kV (serial link) conforming to EN/IEC 61000-4-4; 1 kV (input) conforming to EN/IEC 61000-4-4; 1 kV (transistor output) conforming to EN/IEC 61000-4-4
resistance to conducted disturbances: 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6; 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL); 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emission: Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011; Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011; Radiated emissions - test level: 40 dBμV/m QP class A at 30…230 MHz conforming to EN/IEC 55011; Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011; Radiated emissions - test level: 47 dBμV/m QP class A at 230…1000 MHz conforming to EN/IEC 55011
immunity to microbreaks: 10 ms
ambient air temperature for operation: -10…50 °C (vertical installation); -10…55 °C (horizontal installation)
ambient air temperature for storage: -25…70 °C
relative humidity: 10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage)
IP degree of protection: IP20 with protective cover in place
pollution degree: 2
operating altitude: 0...2000 m
storage altitude: 0…3000 m
vibration resistance: 3.5 mm at 5…8.4 Hz on symmetrical rail; 3 gn at 8.4…150 Hz on symmetrical rail; 3.5 mm at 5…8.4 Hz on panel mounting; 3 gn at 8.4…150 Hz on panel mounting
shock resistance: 15 gn for 11 ms
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: X
Environmental Disclosure: ENVPEP1307080EN
Circularity Profile: ENVEOLI1307080EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free: Yes
© 2018 Alplan Kft.