Schneider-Electric
18692
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: 18692 - RCCB with re-closer - RED - 2 poles - 60 A - class A - 300 mA
Main
range of product: RED
range: Acti 9
product or component type: Residual current circuit breaker (RCCB)
device short name: REDs
protection type: Recloser
poles description: 2P
neutral position: Left
signal contacts composition: 1NO or 1NC or intermittent 1 Hz
[In] rated current: 63 A
earthing system: TN-S; TT
network type: AC
earth-leakage sensitivity: 300 mA
Complementary
device location in system: Outgoer
network frequency: 50 Hz
[Ue] rated operational voltage: 230 V AC 50 Hz phase to neutral
reset: Fault reset earth leakage
test function: Manual at > 100 V
earth-leakage protection time delay: Instantaneous
earth-leakage protection class: Type A
minimum leakage resistance: 5 kOhm at operating; 2.5 kOhm at non-operating
[Im] rated making and breaking capacity: Idm 630 A 230 V
rated conditional short-circuit current: Inc: 15 kA - associated with NG125, 40 A; Inc: 10 kA - associated with iC60L, 63 A; Inc: 15 kA - associated with iC60L, 40 A; Inc: 10 kA - associated with C120H, 63 A; Inc: 10 kA - associated with iC60N, 63 A; Inc: 25 kA - associated with gG fuse, 25 A; Inc: 15 kA - associated with gG fuse, 40 A; Inc: 10 kA - associated with NG125, 63 A; Inc: 15 kA - associated with iC60H, 40 A; Inc: 10 kA - associated with C120L, 63 A; Inc: 10 kA - associated with iC60H, 63 A; Inc: 10 kA - associated with gG fuse, 63 A; Inc: 10 kA - associated with C120N, 63 A
[Ui] rated insulation voltage: 500 V
[Uimp] rated impulse withstand voltage: 4 kV
surge current: 250 A
control type: Toggle
local signalling: 2 LEDs; Residual current device : ON/OFF indication; Recloser : ON/OFF indication
operating mode: Reclosing time: < 90 s; Max nb of consecutive restart: 3; Min interval between 2 closings: 180 s; Stopping restart cycle if insulation fault present; Insulation fault presence monitoring
signalling circuit voltage: AC: 5...230 V; DC: 5...230 V
mounting mode: Fixed
mounting support: 35 mm symmetrical DIN rail
9 mm pitches: 8
height: 115 mm
width: 71 mm
depth: 79.5 mm
net weight: 0.36 kg
mechanical durability: 1000 cycles open-close
connections - terminals: Guard tunnel terminal 35 mm² rigid; Guard tunnel terminal 35 mm² flexible; Guard tunnel terminal 35 mm² flexible with ferrule
auxiliary connection terminal: Tunnel type terminal in 2.5 mm² flexible; Tunnel type terminal in 2.5 mm² rigid; Tunnel type terminal in 2.5 mm² flexible with ferrule
wire stripping length: Power circuit: 12 mm; Signaling: 9 mm
tightening torque: Power circuit: 2 N.m; Signaling: 0.4 N.m
compatibility code: REDs
Environment
standards: EN 61008; IEC 61008
IP degree of protection: IP20
pollution degree: 2
electromagnetic compatibility: 8/20 µs wave immunity, 250 A
tropicalisation: 2
relative humidity: 95 % at 55 °C
ambient air temperature for operation: -5…40 °C
ambient air temperature for storage: -20…60 °C
Offer Sustainability
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Compliant
Toxic heavy metal free: Yes
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: Pro-active China RoHS declaration (out of China RoHS legal scope)
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.