Schneider-Electric
LC1E500E7
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: LC1E500E7 - EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 500A - 48 V AC coil
Main
range: EasyPact
product name: EasyPact TVS
product or component type: Contactor
device short name: LC1E
contactor application: Resistive load; Motor control
utilisation category: AC-3; AC-1
poles description: 3P
pole contact composition: 3 NO
[Ue] rated operational voltage: Power circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current: 500 A (at <55 °C) at <= 440 V AC AC-3 for power circuit; 700 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
motor power kW: 147 kW at 220...230 V AC 50/60 Hz; 250 kW at 380...400 V; 280 kW at 415 V; 295 kW at 440 V; 335 kW at 500 V; 355 kW at 660...690 V
control circuit type: AC at 50/60 Hz
[Uc] control circuit voltage: 48 V AC 50/60 Hz
height: 400 mm
width: 233 mm
depth: 232 mm
net weight: 11.35 kg
Complementary
[Uimp] rated impulse withstand voltage: 8 kV coil not connected to the power circuit conforming to IEC 60947
[Ui] rated insulation voltage: 690 V conforming to IEC 60947-4-1
overvoltage category: III
[Ith] conventional free air thermal current: 700 A (at 40 °C) for power circuit
Irms rated making capacity: 5000 A at 440 V AC for power circuit conforming to IEC 60947-4-1
rated breaking capacity: 4000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 4200 A 40 °C - 10 s for power circuit
associated fuse rating: 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1; 800 A gG at <= 690 V coordination type 1 for power circuit
average impedance: 0.18 mOhm - Ith 700 A 50 Hz for power circuit
power dissipation per pole: 45 W AC-3; 88 W AC-1
control circuit voltage limits: Operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C); Drop-out: 0.35...0.5 Uc at 50/60 Hz (at <55 °C)
operating time: 100...170 ms on opening; 40...75 ms on closing
mechanical durability: 4000000 cycles
maximum operating rate: 2400 cyc/h 55 °C
inrush power in VA: 1100 VA 50 Hz cos phi 0.9 (at 20 °C); 1100 VA 60 Hz cos phi 0.9 (at 20 °C)
hold-in power consumption in VA: 18 VA 50 Hz cos phi 0.9 (at 20 °C); 18 VA 60 Hz cos phi 0.9 (at 20 °C)
heat dissipation: 18 W for control circuit; 18 W
minimum switching current: 5 mA for control circuit
minimum switching voltage: 17 V for control circuit
non-overlap time: 1.5 ms on energisation guaranteed between NC and NO contact; 1.5 ms on de-energisation guaranteed between NC and NO contact
insulation resistance: > 10 MOhm for control circuit
electrical durability: 250000 cycles AC-1; 600000 cycles AC-3
mounting support: Plate
connections - terminals: Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end; Power circuit: cable with lug 2 - external diameter: 240 mm; Power circuit: bars 2 - busbar cross section: 40 x 5 mm
tightening torque: Control circuit: 1.2 N.m; Power circuit: 35 N.m
Environment
standards: IEC 60947-5-1; IEC 60947-4-1; IEC 60947-1
product certifications: EAC; CE
IP degree of protection: IP00 conforming to IEC 60529
protective treatment: (pollution degree 3)
pollution degree: 3
ambient air temperature for operation: -5…55 °C
ambient air temperature for storage: -60…80 °C
permissible ambient air temperature around the device: -20…70 °C at Uc
operating altitude: 3000 m without derating
fire resistance: 850 °C conforming to IEC 60695-2-1
mechanical robustness: Shocks contactor closed: 15 Gn for 11 ms; Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor open: 9 Gn for 11 ms
© 2018 Alplan Kft.