Schneider-Electric
XACS415
Tariff code: 8536508090
Link to the manufacturers site: XACS415 - spring return contact block - 1 NC + 1 NO - front mounting, 30 or 40 mm centres
Main
Range of produc: Harmony XAC
Product or component type: Contact block
component name: XACS
Electrical circuit type: Control circuit
Contact block type: Single
Type of operator: Spring return
Product compatibility: XACA; ZA2B... head
Mechanical interlocking: Without mechanical interlock
Contacts type and composition: 1 NC + 1 NO
Mounting of block: Front mounting
contact operation: Slow-break
Complementary
Connections - terminals: Screw clamp terminals, 1 x 2.5 mm² with or without cable end; Screw clamp terminals, 2 x 1.5 mm² with or without cable end
Horizontal fixing centres: 40 mm
Vertical fixing centres: 30 mm
Mechanical durability: 1000000 cycles
Contact code designation: A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A; Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current: 10 A
[Ui] rated insulation voltage: 500 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-1
Maximum resistance across terminals: 25 MOhm
Short-circuit protection: 10 A fuse protection by cartridge fuse type gG
Rated operational power in W: 42 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 45 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 60 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Rated operational power in VA: 140 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load); 385 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load); 455 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load); 525 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load)
Terminals description ISO n°1: (23-24)NO; (11-12)NC
Terminal identifier: (11-12)NC; (13-14)NO
Net weight: 0.07 kg
Environment
Standards: CSA C22.2 No 14; IEC 60947-5-1; EN 60947-5-1
ambient air temperature for operation: -25…70 °C
Ambient air temperature for storage: -40…70 °C
Vibration resistance: 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance: 100 gn conforming to IEC 60068-2-27
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 3.8 cm
Package 1 Width: 8.6 cm
Package 1 Length: 10.5 cm
Package 1 Weight: 72 g
Unit Type of Package 2: S01
Number of Units in Package 2: 30
Package 2 Height: 15 cm
Package 2 Width: 15 cm
Package 2 Length: 40 cm
Package 2 Weight: 2.198 kg
Offer Sustainability
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free: Yes
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins