Skip to main content

Schneider-Electric
METSEPM8240

PowerLogic PM8000 - PM8240 Panel mount meter - intermediate metering
Net discounted price 1,940.91 EUR
Available when ordered (delivery time: 77 working day(s))
Barcode: 3606480701931
Tariff code: 9028309000

Link to the manufacturers site: METSEPM8240 - PowerLogic PM8000 - PM8240 Panel mount meter - intermediate metering

Main

Range: PowerLogic

Product name: PowerLogic PM8000

Device short name: PM8240

product or component type: Power meter

Market segment: Buildings large building cost management: billing: sub feeder; Buildings small building network management: main incomer; Buildings medium building network management: main incomer; Buildings large building network management: main incomer; Buildings large building network management: sub feeder; Buildings multi-site network management: main incomer; Buildings multi-site network management: sub feeder; Data center network management: main incomer; Data center network management: sub feeder; Healthcare network management: main incomer; Healthcare network management: sub feeder; Industry network management: main incomer; Industry network management: sub feeder; Utility: sub feeder

Variant: Standard

Complementary

Power quality analysis: conforming to EN 50160: 2010 compliance report; conforming to IEEE 519: 2014 compliance report; conforming to IEC 61000-4-30: class S power quality measurement; up to the 63rd harmonic; harmonic distortion; waveform capture; voltage sag and swell detection; programmablity (logic and math functions); conforming to IEC 62586 power quality monitoring; disturbance direction detection; rapid voltage change

device application: Power monitoring; WAGES metering

Type of measurement: Current; Voltage; Frequency; Active and reactive power total; Apparent power total; Power factor total; Active and reactive power per phase, rms; Apparent power per phase, rms; Power factor per phase, rms

[Us] rated supply voltage: 90...415 V AC 45...65 Hz +/- 10 %; 110...415 V DC +/- 10 %

Network frequency: 50 Hz; 60 Hz

[In] rated current: 1 A; 5 A; 10 A

Poles description: 3P + N; 3P; 1P + N

Power consumption in VA: 16 VA at 230 V AC

Display type: Colour TFT LCD

Display resolution: 320 x 240 pixels QVGA

Sampling rate: 256 samples/cycle

Measurement current: 50…10000 mA

Analogue input type: Voltage (impedance 5 MOhm); Current (impedance 0.3 mOhm)

Measurement voltage: 57…400 V AC 42...69 Hz between phase and neutral; 100…690 V AC 42...69 Hz between phases

Frequency measurement range: 42…69 Hz

Number of inputs: 3 digital 30 V AC; 3 digital 60 V DC

Measurement accuracy: Current +/- 0.1 %; Voltage +/- 0.1 %; Active energy +/- 0.2 %

Accuracy class: Class 0.2S active energy conforming to IEC 62053-22; Class 0.2 active energy conforming to ANSI C12.20; Class 0.2 active power conforming to IEC 61557-12; Class 0.5S reactive energy conforming to IEC 62053-24; Class 0.5 power factor conforming to IEC 61557-12; Class 0.2 voltage conforming to IEC 61557-12; Class 0.2 current conforming to IEC 61557-12

Number of outputs: 1 pulse

Information displayed: Voltage; Current; Frequency; Power; Energy consumption; Harmonic distortion

Communication port protocol: Modbus RTU at 115 kbauds - 2-wire; ION at 115 kbauds - 2-wire; DNP3; IEC 61850; Modbus TCP/IP; Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s; RSTP 801.1d 2004

Communication port support: ETHERNET; Screw terminal block: RS485

Communication network type: IPv6 (internet protocol)

Data recording: Min/max of instantaneous values; Waveform logs; Sequence of event recording; Time stamping; Alarm logs; Trending/forecasting; Sag and swell logs; Harmonics logs; GPS synchronisation; Data logs; Event logs; 50 data recorders

Memory capacity: 512 MB

Web services: Customizable home page; File upload/download via FTP; File upload/download via SFTP; Web server; Alarm notification by e-mail; Viewing of captured waveform (FTP); Viewing of captured waveform (web); HTTPS server

Communication service: SMTP e-mail notification; RSTP support; NTP time synchronization; DHCP; PTP time synchronization

Cybersecurity: Enable/disable communication ports; Password protection; Syslog protocol support; Robust security logs; Port hardening

Mounting mode: Flush-mounted

Mounting support: Framework

Installation category: III

Isolation voltage: III400…690 V conforming to IEC 61010-1:ed. 3; III400…690 V conforming to EN 61010-1:ed. 3; III347…600 V conforming to UL 61010-1:ed. 3; III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3

Standards: IEC 61557-12; IEC 62052-11; IEC 62053-24; IEC 62053-22; IEEE 1588; IEC 62586-2; IEC 61326-1

Product certifications: CE; CULus; N998

Width: 96 mm

Depth: 77.5 mm

Height: 96 mm

Net weight: 581 g

Environment

Electromagnetic compatibility: Electrostatic discharge conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test conforming to IEC 61000-4-4; Surge immunity test conforming to IEC 61000-4-5; Conducted RF disturbances conforming to IEC 61000-4-6; Magnetic field at power frequency conforming to IEC 61000-4-8; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11; Immunity to impulse waves conforming to IEC 61000-4-12; Conducted and radiated emissions conforming to EN 55022; Conducted and radiated emissions conforming to EN 55011; Conducted and radiated emissions conforming to FCC part 15; Conducted and radiated emissions conforming to ICES-003; Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579; Surge withstand conforming to IEEE C37.90.1

IP degree of protection: IP54 front: conforming to IEC 60529; IP30 body: conforming to IEC 60529

Relative humidity: 5…95 %

Ambient air temperature for operation: -25…70 °C

Ambient air temperature for storage: -40…85 °C

Operating altitude: 3000 m

Compatibility code: PM8240

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 14 cm

Package 1 Width: 14 cm

Package 1 Length: 18.5 cm

Package 1 Weight: 0.954 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant with Exemptions

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1406023EN

Circularity Profile: ENVEOLI1406023EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins