Skip to main content

Schneider-Electric
LC7K12015M7

TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NC aux. - 220...230 V AC coil
Barcode: 3389110849905
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: LC7K12015M7 - TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NC aux. - 220...230 V AC coil

Main

range of product: TeSys K

range: TeSys

product or component type: Contactor

product name: TeSys K

device short name: LC7K

device application: Control

contactor application: Motor control; Resistive load

Complementary

utilisation category: AC-4; AC-1; AC-3

poles description: 3P

pole contact composition: 3 NO

[Ue] rated operational voltage: Power circuit: 690 V AC 50/60 Hz; Signalling circuit: <= 690 V AC 50/60 Hz

[Ie] rated operational current: 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit; 12 A at <= 440 V AC AC-3 for power circuit; 16 A (at <70 °C) at 690 V AC AC-1 for power circuit

control circuit type: AC at 50/60 Hz silent

[Uc] control circuit voltage: 220...230 V AC 50/60 Hz

motor power kW: 4 kW at 480 V AC 50/60 Hz AC-3; 4 kW at 500...600 V AC 50/60 Hz AC-3; 4 kW at 660...690 V AC 50/60 Hz AC-3; 2.2 kW at 400 V AC 50/60 Hz AC-4; 3 kW at 220...230 V AC 50/60 Hz AC-3; 5.5 kW at 380...415 V AC 50/60 Hz AC-3; 5.5 kW at 440 V AC 50/60 Hz AC-3

auxiliary contact composition: 1 NC

[Uimp] rated impulse withstand voltage: 8 kV

overvoltage category: III

[Ith] conventional free air thermal current: 20 A (at 50 °C) for power circuit; 10 A (at 50 °C) for signalling circuit

Irms rated making capacity: 110 A AC for signalling circuit conforming to IEC 60947; 144 A AC for power circuit conforming to NF C 63-110; 144 A AC for power circuit conforming to IEC 60947

rated breaking capacity: 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947

[Icw] rated short-time withstand current: 115 A 50 °C - 1 s for power circuit; 105 A 50 °C - 5 s for power circuit; 100 A 50 °C - 10 s for power circuit; 75 A 50 °C - 30 s for power circuit; 55 A 50 °C - 1 min for power circuit; 50 A 50 °C - 3 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit; 25 A 50 °C - >= 15 min for power circuit

associated fuse rating: 25 A gG at <= 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660

average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit

[Ui] rated insulation voltage: Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14

insulation resistance: > 10 MOhm for signalling circuit

inrush power in VA: 3 VA (at 20 °C)

hold-in power consumption in VA: 3 VA (at 20 °C)

heat dissipation: 3 W

control circuit voltage limits: Operational: 0.85...1.1 Uc (at <50 °C); Drop-out: 0.1...0.75 Uc (at <50 °C)

connections - terminals: Solder pins - busbar cross section: 1.5 x 0.9 mm

maximum operating rate: 3600 cyc/h

auxiliary contacts type: type instantaneous 1 NC

signalling circuit frequency: <= 400 Hz

minimum switching current: 5 mA for signalling circuit

minimum switching voltage: 17 V for signalling circuit

mounting support: Printed circuit boards

operating time: 30...40 ms coil energisation and NO closing; 30 ms coil de-energisation and NO opening

safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

non overlap distance: 0.5 mm

mechanical durability: 10 Mcycles

electrical durability: 0.3 Mcycles 20 A AC-1 at Ue <= 440 V; 1.3 Mcycles 12 A AC-3 at Ue <= 440 V

mechanical robustness: Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6

depth: 57 mm

net weight: 0.225 kg

compatibility code: LC7K

Environment

standards: BS 5424; IEC 60947; NF C 63-110; VDE 0660

product certifications: CSA; UL

IP degree of protection: IP2x conforming to VDE 0106

protective treatment: TC conforming to IEC 60068; TC conforming to DIN 50016

ambient air temperature for storage: -50…80 °C

operating altitude: 2000 m without derating

flame retardance: V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102

Offer Sustainability

Sustainable offer status: Green Premium product

REACh free of SVHC: Yes

EU RoHS Directive: Compliant

Toxic heavy metal free: Yes

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation:  Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure: ENVPEP1503003EN

Circularity Profile: ENVEOLI1503003EN

© 2018 Alplan Kft.