Schneider-Electric
LC3D80E7A64
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: LC3D80E7A64 - TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 48 V AC coil
Main
range of product: TeSys D
range: TeSys
product name: TeSys D
product or component type: Star delta starter
device short name: LC3D
contactor application: Motor control
utilisation category: AC-3
device presentation: Pre-wired
poles description: 3 x 3P
pole contact composition: 3 x 3 NO
[Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current: 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
motor power kW: 37 kW at 220/230 V AC 50/60 Hz; 75 kW at 380/400 V AC 50/60 Hz; 75 kW at 415 V AC 50/60 Hz; 75 kW at 440 V AC 50/60 Hz
control circuit type: AC at 50/60 Hz
[Uc] control circuit voltage: 48 V AC 50/60 Hz
auxiliary contact composition: 1 NC for KM2 line contactor; 1 NO for KM3 delta contactor
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947
overvoltage category: III
[Ui] rated insulation voltage: Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1; Signalling circuit: 1000 V conforming to IEC 60947-1
electrical durability: 10 Mcycles 80 A AC-3 at Ue <= 440 V
interlocking type: Mechanical
mounting support: Plate
standards: IEC 60947-4-1; CSA C22.2 No 14; EN 60947-5-1; EN 60947-4-1; IEC 60947-5-1; UL 508
product certifications: CSA; CCC; GL; BV; LROS (Lloyds register of shipping); DNV; RINA; GOST; UL
Complementary
connections - terminals: Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 4…25 mm² - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 4…16 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 4…25 mm² - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end
tightening torque: Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 12 N.m - on screw clamp terminals - with screwdriver flat Ø 6...8 mm
mechanical durability: 4 Mcycles
maximum operating rate: 30 cyc/h 60 °C
starting time: 30 s
coil technology: Without built-in suppressor module
control circuit voltage limits: Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C); Operational: 0.8...1.1 Uc at 50 Hz (at <55 °C); Operational: 0.85...1.1 Uc at 60 Hz (at <55 °C)
inrush power in VA: 140 VA 60 Hz cos phi 0.75 (at 20 °C); 160 VA 50 Hz cos phi 0.75 (at 20 °C)
hold-in power consumption in VA: 13 VA 60 Hz cos phi 0.3 (at 20 °C); 15 VA 50 Hz cos phi 0.3 (at 20 °C)
heat dissipation: 4…5 W at 50/60 Hz
auxiliary contacts type: Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC; Mirror contact conforming to IEC 60947-4-1 3 x 1 NC
signalling circuit frequency: 25...400 Hz
minimum switching current: 5 mA for signalling circuit
switching voltage: 17 V for signalling circuit
non-overlap time: 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
width: 311 mm
height: 143 mm
depth: 183 mm
net weight: 5.4 kg
Environment
insulation resistance: > 10 MOhm for signalling circuit
IP degree of protection: IP20 front face conforming to IEC 60529
protective treatment: TH conforming to IEC 60068-2-30
pollution degree: 3
ambient air temperature for storage: -60…80 °C
ambient air temperature for operation: -40…60 °C; 60…70 °C with derating
operating altitude: 3000 m
fire resistance: 850 °C conforming to IEC 60695-2-1
flame retardance: V1 conforming to UL 94
mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 Hz; Shocks contactor open: 8 Gn for 11 ms; Vibrations contactor closed: 3 Gn, 5...300 Hz; Shocks contactor closed: 10 Gn for 11 ms
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Compliant
Toxic heavy metal free: Yes
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure: ENVPEP1503009EN
Circularity Profile: ENVEOLI1503009EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free: Yes
© 2018 Alplan Kft.