Skip to main content

Schneider-Electric
LC1D18KUE

TeSys D contactor 3P 18A AC-3 up to 440V coil 100-250V AC/DC
Net discounted price 78.46 EUR
Available when ordered (delivery time: 92 working day(s))
Barcode: 3606480987717
Tariff code: 8536490099

Link to the manufacturers site: LC1D18KUE - TeSys D contactor 3P 18A AC-3 up to 440V coil 100-250V AC/DC

Main

Range: TeSys; TeSys Deca

Range of produc: TeSys Deca

Product or component type: Contactor

Device short name: LC1D

contactor application: Motor control; Resistive load

utilisation category: AC-1; AC-3; AC-3e

Poles description: 3P

[Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz

[Ie] rated operational current: 18 A (at <60 °C) at <= 440 V AC-3 for power circuit; 32 A (at <60 °C) at <= 440 V AC-1 for power circuit; 18 A (at <60 °C) at <= 440 V AC-3e for power circuit

[Uc] control circuit voltage: 100...250 V AC 50/60 Hz; 100...250 V DC

Complementary

Motor power kW: 4 kW at 220...230 V AC 50 Hz (AC-3); 7.5 kW at 380...400 V AC 50 Hz (AC-3); 9 kW at 415 V AC 50 Hz (AC-3); 9 kW at 440 V AC 50 Hz (AC-3); 10 kW at 500 V AC 50 Hz (AC-3); 10 kW at 660...690 V AC 50 Hz (AC-3); 4 kW at 220...230 V AC 50 Hz (AC-3e); 7.5 kW at 380...400 V AC 50 Hz (AC-3e); 9 kW at 415 V AC 50 Hz (AC-3e); 9 kW at 440 V AC 50 Hz (AC-3e); 10 kW at 500 V AC 50 Hz (AC-3e); 10 kW at 660...690 V AC 50 Hz (AC-3e)

Motor power hp: 1 hp at 115 V AC 60 Hz for 1 phase motors; 3 hp at 230/240 V AC 60 Hz for 1 phase motors; 5 hp at 200/208 V AC 60 Hz for 3 phases motors; 5 hp at 230/240 V AC 60 Hz for 3 phases motors; 10 hp at 460/480 V AC 60 Hz for 3 phases motors; 15 hp at 575/600 V AC 60 Hz for 3 phases motors

Compatibility code: LC1D

Pole contact composition: 3 NO

Protective cover: With

[Ith] conventional free air thermal current: 10 A (at 60 °C) for signalling circuit; 32 A (at 60 °C) for power circuit

Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 300 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity: 300 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current: 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit; 40 A 40 °C - 10 min for power circuit; 84 A 40 °C - 1 min for power circuit; 145 A 40 °C - 10 s for power circuit; 240 A 40 °C - 1 s for power circuit

Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1; 50 A gG at <= 690 V coordination type 1 for power circuit; 35 A gG at <= 690 V coordination type 2 for power circuit

Average impedance: 2.5 mOhm - Ith 32 A 50 Hz for power circuit

Power dissipation per pole: 2.5 W AC-1; 0.8 W AC-3; 0.8 W AC-3e

[Ui] rated insulation voltage: Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-1

Overvoltage category: III

Pollution degree: 3

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947

Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Mechanical durability: 15 Mcycles

Electrical durability: 2.2 Mcycles 15 A AC-3 at Ue <= 440 V; 0.9 Mcycles 32 A AC-1 at Ue <= 440 V; 2.2 Mcycles 15 A AC-3e at Ue <= 440 V

Control circuit type: AC/DC at 50/60 Hz AC/DC electronic

Coil technology: Built-in bidirectional peak limiting

Control circuit voltage limits: <= 0.1 Uc (-40…70 °C):drop-out AC/DC; 0.85...1.1 Uc (-40…60 °C):operational AC/DC; 1...1.1 Uc (60…70 °C):operational AC/DC

Inrush power in VA: 25 VA 50/60 Hz (at 20 °C)

Inrush power in W: 18 W (at 20 °C)

Hold-in power consumption in VA: 1.6 VA 50/60 Hz (at 20 °C)

Hold-in power consumption in W: 1.1 W at 20 °C

Heat dissipation: 1.1 W at 50/60 Hz

Operating time: 45...55 ms closing; 20...90 ms opening

Maximum operating rate: 3600 cyc/h 60 °C

Connections - terminals: Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid; Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid; Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid

Tightening torque: Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Auxiliary contact composition: 1 NO + 1 NC

Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency: 25...400 Hz

Minimum switching voltage: 17 V for signalling circuit

Minimum switching current: 5 mA for signalling circuit

Insulation resistance: > 10 MOhm for signalling circuit

Non-overlap time: 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact

mounting support: Plate; Rail

Environment

Standards: EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; CSA C22.2 No 60947-4-1; IEC 60335-1

product certifications: CCC; CSA; EAC; UL; KC; DNV-GL; LROS (Lloyds register of shipping); UKCA

IP degree of protection: IP20 front face conforming to IEC 60529

Climatic withstand: conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat

Permissible ambient air temperature around the device: -40…60 °C; 60…70 °C with derating

Operating altitude: 0...3000 m

Fire resistance: 850 °C conforming to IEC 60695-2-1

Flame retardance: V1 conforming to UL 94

Mechanical robustness: Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor open (10 Gn for 11 ms) ; Shocks contactor closed (15 Gn for 11 ms)

height: 77 mm

Width: 45 mm

Depth: 86 mm

Net weight: 0.378 kg

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 5.200 cm

Package 1 Width: 9.200 cm

Package 1 Length: 11.200 cm

Package 1 Weight: 394.000 g

Unit Type of Package 2: S02

Number of Units in Package 2: 15

Package 2 Height: 15.000 cm

Package 2 Width: 30.000 cm

Package 2 Length: 40.000 cm

Package 2 Weight: 6.202 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant with Exemptions

Mercury free: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1609001EN

Circularity Profile: ENVEOLI1609001EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Halogen content performance: Halogen free plastic parts & cables product

© 2018 Alplan Kft.