Schneider-Electric
GV7RE80
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: GV7RE80 - TeSys GV7 - circuit breaker - 3P - AC-3 - 48...80 A - thermal-magnetic
Main
range: TeSys
range of product: TeSys GV7
product name: TeSys GV7
product or component type: Circuit breaker
device short name: GV7R
device application: Motor
poles description: 3P
network type: AC
utilisation category: AC-3 conforming to IEC 60947-4-1
network frequency: 50/60 Hz conforming to IEC 60947-4-1
breaking capacity: 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2; 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2; 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity: 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 220/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 380/415 V AC 50/60 Hz conforming to IEC 60947-2; 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2; 50 % at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
trip unit rating: 48…80 A
trip unit technology: Thermal-magnetic
Complementary
mounting mode: By screws; By clips
mounting support: Kit for fixing the switchgear; Rail; Panel mounting; Flush
mounting position: Vertical
motor power kW: 37 kW at 400...415 V AC 50/60 Hz; 45 kW at 500 V AC 50/60 Hz; 55 kW at 500 V AC 50/60 Hz; 55 kW at 660...690 V AC 50/60 Hz
control type: Rocker lever
[In] rated current: 80 A
[Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage: 750 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current: 80 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2
power dissipation: 5 W
power dissipation per pole: 5 W
mechanical durability: 50000 cycles
electrical durability: 30000 cycles for AC-3 at 440 V In; 50000 cycles for AC-3 at 440 V In/2
maximum operating rate: 25 cyc/h
rated duty: Continuous conforming to IEC 60947-4-1
connection pitch: 35 mm without spreaders; 45 mm with spreaders
connections - terminals: Bars; Cable with lug - external diameter: 10 mm; Screw; Bare cable connectors 1.5…95 mm²
tightening torque: 10 N.m on screw M6 screw type ; 15 N.m on bare cable connectors for cable 1.5…95 mm²
mechanical robustness: Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations: 2.5 Gn, 0...25 Hz conforming to IEC 60068-2-6
suitability for isolation: Yes conforming to IEC 60947-1
phase failure sensitivity: Yes conforming to IEC 60947-4-1 § 7-2-1-5-2
height: 161 mm
width: 105 mm
depth: 111 mm
net weight: 2.04 kg
compatibility code: GV7RE
Environment
standards: VDE 0660; NF C 63-650; EN/IEC 60947-4-1; NF C 63-120; NF C 79-130; VDE 0113; EN/IEC 60947-2; EN/IEC 60947-1
product certifications: DNV; UL
protective treatment: TC
IP degree of protection: IP405 conforming to IEC 60529 (with terminal shrouds)
pollution degree: 3
ambient air temperature for operation: -25…70 °C
ambient air temperature for storage: -55…95 °C
fire resistance: 960 °C conforming to IEC 60695-2-1
operating altitude: 2000 m
Offer Sustainability
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Environmental Disclosure: ENVPEP050906EN
Circularity Profile: ENVEOLI110801EN_V2
© 2018 Alplan Kft.