TeSys GV7 - circuit breaker - 3P - AC-3 - 25...40 A - thermal-magnetic
Barcode: 3389110602579
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: GV7RE40 - TeSys GV7 - circuit breaker - 3P - AC-3 - 25...40 A - thermal-magnetic

Main

range: TeSys

range of product: TeSys GV7

product name: TeSys GV7

product or component type: Circuit breaker

device short name: GV7R

device application: Motor

poles description: 3P

network type: AC

utilisation category: AC-3 conforming to IEC 60947-4-1

network frequency: 50/60 Hz conforming to IEC 60947-4-1

breaking capacity: 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2; 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2; 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2

[Ics] rated service short-circuit breaking capacity: 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 220/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 380/415 V AC 50/60 Hz conforming to IEC 60947-2; 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2; 50 % at 660/690 V AC 50/60 Hz conforming to IEC 60947-2

trip unit rating: 25…40 A

trip unit technology: Thermal-magnetic

Complementary

mounting mode: By screws; By clips

mounting support: Rail; Panel mounting; Kit for fixing the switchgear; Flush

mounting position: Vertical

motor power kW: 22 kW at 500 V AC 50/60 Hz; 22 kW at 660...690 V AC 50/60 Hz; 18.5 kW at 400...415 V AC 50/60 Hz; 18.5 kW at 500 V AC 50/60 Hz

control type: Rocker lever

[In] rated current: 40 A

[Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2

[Ui] rated insulation voltage: 750 V AC 50/60 Hz conforming to IEC 60947-2

[Ith] conventional free air thermal current: 40 A conforming to IEC 60947-4-1

[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2

power dissipation: 5 W

power dissipation per pole: 5 W

mechanical durability: 50000 cycles

electrical durability: 30000 cycles for AC-3 at 440 V In; 50000 cycles for AC-3 at 440 V In/2

maximum operating rate: 25 cyc/h

rated duty: Continuous conforming to IEC 60947-4-1

connection pitch: 35 mm without spreaders; 45 mm with spreaders

connections - terminals: Bars; Cable with lug - external diameter: 10 mm; Screw; Bare cable connectors 1.5…95 mm²

tightening torque: 10 N.m on screw M6 screw type ; 15 N.m on bare cable connectors for cable 1.5…95 mm²

mechanical robustness: Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations: 2.5 Gn, 0...25 Hz conforming to IEC 60068-2-6

suitability for isolation: Yes conforming to IEC 60947-1

phase failure sensitivity: Yes conforming to IEC 60947-4-1 § 7-2-1-5-2

height: 161 mm

width: 105 mm

depth: 111 mm

net weight: 2.01 kg

compatibility code: GV7RE

Environment

standards: EN/IEC 60947-4-1; EN/IEC 60947-2; VDE 0113; VDE 0660; EN/IEC 60947-1; NF C 63-650; NF C 63-120; NF C 79-130

product certifications: DNV; UL

protective treatment: TC

IP degree of protection: IP405 conforming to IEC 60529 (with terminal shrouds)

pollution degree: 3

ambient air temperature for operation: -25…70 °C

ambient air temperature for storage: -55…95 °C

fire resistance: 960 °C conforming to IEC 60695-2-1

operating altitude: 2000 m