Schneider-Electric
BMXART0414

analog input module X80 - 4 inputs - temperature
Net discounted price 614.95 EUR
Available when ordered (delivery time: 50 working day(s))
Barcode: 3595863910186
Tariff code: 8538909999

Link to the manufacturers site: BMXART0414 - analog input module X80 - 4 inputs - temperature

Main

Range of produc: Modicon X80

Product or component type: Analog input module

Electrical connection: 40 ways 1 connector

Input output isolation: Isolated

Input level: Low level

analogue input number: 4

Analogue input type: Voltage +/- 1.28 V; Voltage +/- 160 mV; Voltage +/- 320 mV; Voltage +/- 40 mV; Voltage +/- 640 mV; Voltage +/- 80 mV; Resistor 400 Ohm 2 wires; Resistor 400 Ohm 3 wires; Resistor 400 Ohm 4 wires; Resistor 4000 Ohm 2 wires; Resistor 4000 Ohm 3 wires; Resistor 4000 Ohm 4 wires; Temperature probe -100...+260 °C Cu 10; Temperature probe -100...+450 °C Pt 100 conforming to UL/JIS; Temperature probe -100...+450 °C Pt 1000 conforming to UL/JIS; Temperature probe -200...+850 °C Pt 100 conforming to IEC; Temperature probe -200...+850 °C Pt 1000 conforming to IEC; Temperature probe -60...+180 °C Ni 100; Temperature probe -60...+180 °C Ni 1000; Thermocouple +130...+1820 °C thermocouple B; Thermocouple +270...+1300 °C thermocouple N; Thermocouple -200...+600 °C thermocouple U; Thermocouple -200...+760 °C thermocouple J; Thermocouple -200...+900 °C thermocouple L; Thermocouple -270...+1000 °C thermocouple E; Thermocouple -270...+1370 °C thermocouple K; Thermocouple -270...+400 °C thermocouple T; Thermocouple -50...+1769 °C thermocouple R; Thermocouple -50...+1769 °C thermocouple S

Complementary

Analog/digital conversion: Sigma delta 16 bits

Analogue input resolution: 15 bits + sign

Permitted overload on inputs: +/- 7.5 V +/- 1.28 V; +/- 7.5 V +/- 160 mV; +/- 7.5 V +/- 320 mV; +/- 7.5 V +/- 40 mV; +/- 7.5 V +/- 640 mV; +/- 7.5 V +/- 80 mV

Common mode rejection: 120 dB 50/60 Hz

Differential mode rejection: 60 dB 50/60 Hz

Cold junction compensation: External by Pt100 probe

type of filter: First order digital filtering

Nominal read cycle time: 400 ms with temperature probe; 200 ms with thermocouple

Measurement error: +/- 0.7 °C Ni 1000 25 °C; +/- 1.3 °C Ni 1000 0...60 °C; +/- 2 °C Pt 100 0...60 °C; +/- 2 °C Pt 1000 0...60 °C; +/- 2.1 °C Ni 100 25 °C; +/- 2.1 °C Pt 100 25 °C; +/- 2.1 °C Pt 1000 25 °C; +/- 2.7 °C thermocouple U 25 °C; +/- 2.8 °C thermocouple J 25 °C; +/- 3 °C Ni 100 0...60 °C; +/- 3 °C thermocouple L 25 °C; +/- 3.2 °C thermocouple R 25 °C; +/- 3.2 °C thermocouple S 25 °C; +/- 3.5 °C thermocouple B 25 °C; +/- 3.7 °C thermocouple E 25 °C; +/- 3.7 °C thermocouple K 25 °C; +/- 3.7 °C thermocouple N 25 °C; +/- 3.7 °C thermocouple T 25 °C; +/- 4 °C Cu 10 0...60 °C; +/- 4 °C Cu 10 25 °C; +/- 4.5 °C thermocouple J 0...60 °C; +/- 4.5 °C thermocouple L 0...60 °C; +/- 4.5 °C thermocouple R 0...60 °C; +/- 4.5 °C thermocouple S 0...60 °C; +/- 4.5 °C thermocouple U 0...60 °C; +/- 5 °C thermocouple B 0...60 °C; +/- 5 °C thermocouple E 0...60 °C; +/- 5 °C thermocouple K 0...60 °C; +/- 5 °C thermocouple N 0...60 °C; +/- 5 °C thermocouple T 0...60 °C; <= 0.15 % of full scale +/- 1.28 V 0...60 °C; <= 0.15 % of full scale +/- 160 mV 0...60 °C; <= 0.15 % of full scale +/- 320 mV 0...60 °C; <= 0.15 % of full scale +/- 40 mV 0...60 °C; <= 0.15 % of full scale +/- 640 mV 0...60 °C; <= 0.15 % of full scale +/- 80 mV 0...60 °C; <= 0.2 % of full scale 400 Ohm 0...60 °C; <= 0.2 % of full scale 4000 Ohm 0...60 °C; 0.05 % of full scale +/- 1.28 V 25 °C; 0.05 % of full scale +/- 160 mV 25 °C; 0.05 % of full scale +/- 320 mV 25 °C; 0.05 % of full scale +/- 40 mV 25 °C; 0.05 % of full scale +/- 640 mV 25 °C; 0.05 % of full scale +/- 80 mV 25 °C; 0.12 % of full scale 400 Ohm 25 °C; 0.12 % of full scale 4000 Ohm 25 °C

Temperature drift: 25 ppm/°C 400 Ohm; 25 ppm/°C 4000 Ohm; 25 ppm/°C Ni 1000; 25 ppm/°C thermocouple B; 25 ppm/°C thermocouple E; 25 ppm/°C thermocouple J; 25 ppm/°C thermocouple K; 25 ppm/°C thermocouple L; 25 ppm/°C thermocouple N; 25 ppm/°C thermocouple R; 25 ppm/°C thermocouple S; 25 ppm/°C thermocouple T; 25 ppm/°C thermocouple U; 30 ppm/°C +/- 1.28 V; 30 ppm/°C +/- 160 mV; 30 ppm/°C +/- 320 mV; 30 ppm/°C +/- 40 mV; 30 ppm/°C +/- 640 mV; 30 ppm/°C +/- 80 mV; 30 ppm/°C Cu 10; 30 ppm/°C Ni 100; 30 ppm/°C Pt 100; 30 ppm/°C Pt 1000

Recalibration: Internal

Isolation voltage: 1400 V DC between channels and bus; 750 V DC between channels; 750 V DC between channels and ground

Detection type: Open circuit Cu 10; Open circuit Ni 100; Open circuit Ni 1000; Open circuit Pt 100; Open circuit Pt 1000; Open circuit thermocouple B; Open circuit thermocouple E; Open circuit thermocouple J; Open circuit thermocouple K; Open circuit thermocouple L; Open circuit thermocouple N; Open circuit thermocouple R; Open circuit thermocouple S; Open circuit thermocouple T; Open circuit thermocouple U

Maximum wiring resistance: 20 Ohm 2 wires Cu 10; 20 Ohm 2 wires Ni 100; 20 Ohm 2 wires Pt 100; 20 Ohm 3 wires Cu 10; 20 Ohm 3 wires Ni 100; 20 Ohm 3 wires Pt 100; 200 Ohm 2 wires Ni 1000; 200 Ohm 2 wires Pt 1000; 200 Ohm 3 wires Ni 1000; 200 Ohm 3 wires Pt 1000; 50 Ohm 4 wires Cu 10; 50 Ohm 4 wires Ni 100; 50 Ohm 4 wires Pt 100; 500 Ohm 4 wires Ni 1000; 500 Ohm 4 wires Pt 1000

Measurement resolution: 0.1 °C Cu 10; 0.1 °C Ni 100; 0.1 °C Ni 1000; 0.1 °C Pt 100; 0.1 °C Pt 1000; 0.1 °C thermocouple B; 0.1 °C thermocouple E; 0.1 °C thermocouple J; 0.1 °C thermocouple K; 0.1 °C thermocouple L; 0.1 °C thermocouple N; 0.1 °C thermocouple R; 0.1 °C thermocouple S; 0.1 °C thermocouple T; 0.1 °C thermocouple U; 1280/2exp14 mV +/- 1.28 V; 160/2exp14 mV +/- 160 mV; 320/2exp14 mV +/- 320 mV; 40/2exp14 mV +/- 40 mV; 12.5 mOhm 400 Ohm; 125 mOhm 4000 Ohm; 640/2exp14 mV +/- 640 mV; 80/2exp14 mV +/- 80 mV

Maximum conversion value: +/- 100 % 400 Ohm; +/- 100 % 4000 Ohm; +/- 102.5 % +/- 1.28 V; +/- 102.5 % +/- 160 mV; +/- 102.5 % +/- 320 mV; +/- 102.5 % +/- 40 mV; +/- 102.5 % +/- 640 mV; +/- 102.5 % +/- 80 mV

MTBF reliability: 1400000 H

Operating altitude: 0...2000 m; 2000...5000 m with derating factor

Status LED: 1 LED (green) RUN; 1 LED per channel (green) channel diagnostic; 1 LED (red) ERR; 1 LED (red) I/O

Net weight: 0.135 kg

Current consumption: 150 mA at 3.3 V DC; 40 mA at 24 V DC

Environment

Vibration resistance: 3 gn

Shock resistance: 30 gn

Ambient air temperature for storage: -40…85 °C

ambient air temperature for operation: 0…60 °C

Relative humidity: 5…95 % at 55 °C without condensation

IP degree of protection: IP20

Directives: 2014/35/EU - low voltage directive; 2014/30/EU - electromagnetic compatibility

product certifications: EAC; RCM; UL; Merchant Navy; CSA; CE

Standards: EN 61131-2; EN 61000-6-4; EN 61000-6-2; EN 61010-2-201

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 5.500 cm

Package 1 Width: 11.000 cm

Package 1 Length: 11.500 cm

Package 1 Weight: 164.000 g

Unit Type of Package 2: S02

Number of Units in Package 2: 15

Package 2 Height: 15.000 cm

Package 2 Width: 30.000 cm

Package 2 Length: 40.000 cm

Package 2 Weight: 2.750 kg

Offer Sustainability

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins