Main

Range of produc: OsiSense XC

Series name: Special format

Product or component type: Limit switch contact block

Device short name: ZC1A

Product compatibility: XC1AC16.

Electrical connection: Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²

Number of poles: 2

Contacts type and composition: 2 NC

contact operation: Slow-break, staggered

Contacts material: Silver plated contacts

Positive opening: Without

Complementary

Contacts insulation form: Za

Minimum actuation speed: 6 m/min

Maximum resistance across terminals: 8 mOhm conforming to IEC 60255-7 category 3

[Ithe] conventional enclosed thermal current: 10 A

[Ui] rated insulation voltage: 500 V AC conforming to IEC 60947-5-1; 500 V AC conforming to NF C 20-040; 600 V DC conforming to IEC 60947-5-1; 600 V DC conforming to NF C 20-040; 600 V AC conforming to CSA C22.2 No 14; 600 V DC conforming to CSA C22.2 No 14

Short-circuit protection: 10 A cartridge fuse, type gG

Electrical durability: 1000000 cycles, AC-15 110 V, 900 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15 230 V, 1900 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15 48 V, 450 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13 110 V, 100 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13 230 V, 95 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13 48 V, 100 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 3000000 cycles, AC-15 110 V, 350 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 3000000 cycles, AC-15 230 V, 430 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 3000000 cycles, AC-15 48 V, 170 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 3000000 cycles, DC-13 110 V, 40 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 3000000 cycles, DC-13 230 V, 33 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 3000000 cycles, DC-13 48 V, 35 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

Compatibility code: ZC1A

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 2.0 cm

Package 1 Width: 5.5 cm

Package 1 Length: 6.2 cm

Package 1 Weight: 44.0 g

Offer Sustainability

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

RoHS exemption information: Yes

© 2018 Alplan Kft.