Skip to main content

Schneider-Electric
LP4K12105BW3

TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NO aux. - 24 V DC coil
Barcode: 3389110791204
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: LP4K12105BW3 - TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NO aux. - 24 V DC coil

Main

range of product: TeSys K

range: TeSys

product or component type: Contactor

device short name: LP4K

contactor application: Motor control; Resistive load

utilisation category: AC-4; AC-1; AC-3

poles description: 3P

pole contact composition: 3 NO

[Ie] rated operational current: 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit; 12 A at <= 440 V AC AC-3 for power circuit; 16 A (at <70 °C) at 690 V AC AC-1 for power circuit

auxiliary contact composition: 1 NO

Complementary

coil technology: Built-in bidirectional peak limiting diode suppressor

auxiliary contacts type: type instantaneous 1 NO

control circuit voltage limits: Operational: 0.7...1.30 Uc (at <50 °C); Drop-out: 0.1...0.7 Uc (at <50 °C)

[Ui] rated insulation voltage: Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14

[Uimp] rated impulse withstand voltage: 8 kV

overvoltage category: III

mounting support: Printed circuit boards

flame retardance: V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102

[Ue] rated operational voltage: Power circuit: 690 V AC 50/60 Hz; Signalling circuit: <= 690 V AC 50/60 Hz

[Ith] conventional free air thermal current: 20 A (at 50 °C) for power circuit; 10 A (at 50 °C) for signalling circuit

Irms rated making capacity: 110 A AC for signalling circuit conforming to IEC 60947; 144 A AC for power circuit conforming to NF C 63-110; 144 A AC for power circuit conforming to IEC 60947

rated breaking capacity: 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947

associated fuse rating: 25 A gG at <= 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660

average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit

inrush power in W: 1.8 W (at 20 °C)

hold-in power consumption in W: 1.8 W at 20 °C

operating time: 10...20 ms coil de-energisation and NO opening; 30...40 ms coil energisation and NO closing

safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

mechanical durability: 30 Mcycles

maximum operating rate: 3600 cyc/h

minimum switching current: 5 mA for signalling circuit

minimum switching voltage: 17 V for signalling circuit

insulation resistance: > 10 MOhm for signalling circuit

height: 58 mm

width: 45 mm

depth: 57 mm

net weight: 0.235 kg

compatibility code: LP4K

Environment

product certifications: CSA; UL

ambient air temperature for operation: -25…50 °C

ambient air temperature for storage: -50…80 °C

operating altitude: 2000 m without derating

Offer Sustainability

Sustainable offer status: Green Premium product

REACh free of SVHC: Yes

EU RoHS Directive: Compliant

Toxic heavy metal free: Yes

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation:  Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure: ENVPEP1503003EN

Circularity Profile: ENVEOLI1503003EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins