Schneider-Electric
LC1D50AG7TQ
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: LC1D50AG7TQ - contactor TeSys LC1-D - 3 poles- AC-3 - 440 V 50 A - coil 120 V AC
Main
range of product: TeSys D; TeSys Deca
range: TeSys; TeSys Deca
product or component type: Contactor
device short name: LC1D
contactor application: Motor control; Resistive load
utilisation category: AC-4; AC-2; AC-1; AC-3; AC-3e
control circuit type: AC at 60 Hz
poles description: 3P
pole contact composition: 3 NO
[Ie] rated operational current: 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit; 50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
motor power kW: 22 kW at 380...400 V AC 50 Hz (AC-3); 25 kW at 415 V AC 50 Hz (AC-3); 30 kW at 440 V AC 50 Hz (AC-3); 30 kW at 500 V AC 50 Hz (AC-3); 33 kW at 660...690 V AC 50 Hz (AC-3); 15 kW at 220...230 V AC 50 Hz (AC-3); 11 kW at 400 V AC 50 Hz (AC-4); 22 kW at 380...400 V AC 50 Hz (AC-3e); 25 kW at 415 V AC 50 Hz (AC-3e); 30 kW at 440 V AC 50 Hz (AC-3e); 30 kW at 500 V AC 50 Hz (AC-3e); 33 kW at 660...690 V AC 50 Hz (AC-3e); 15 kW at 220...230 V AC 50 Hz (AC-3e)
Quantity per set: Set of 10
Complementary
coil technology: Without built-in bidirectional peak limiting diode suppressor
protective cover: With
motor power hp: 3 hp at 115 V AC 60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors; 15 hp at 200/208 V AC 60 Hz for 3 phases motors; 15 hp at 230/240 V AC 60 Hz for 3 phases motors; 40 hp at 460/480 V AC 60 Hz for 3 phases motors; 40 hp at 575/600 V AC 60 Hz for 3 phases motors
auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
auxiliary contact composition: 1 NO + 1 NC
[Uc] control circuit voltage: 120 V AC 60 Hz
control circuit voltage limits: 0.3...0.6 Uc (-40…70 °C):drop-out AC 60 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 60 Hz
[Ui] rated insulation voltage: Control circuit: 600 V CSA certified; Control circuit: 600 V UL certified; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Control circuit: 690 V conforming to IEC 60947-1; Power circuit: 690 V conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
overvoltage category: III
mounting support: Rail; Plate
flame retardance: V1 conforming to UL 94
connections - terminals: Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²rigid; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²rigid; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²rigid; Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²rigid; Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible without cable end; Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible without cable end; Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible with cable end; Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible with cable end
tightening torque: Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2; Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² - with screwdriver hex (Allen key)4 mm; Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 35 mm² - with screwdriver hex (Allen key)4 mm
[Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz
[Ith] conventional free air thermal current: 10 A (at 60 °C) for control circuit; 80 A (at 60 °C) for power circuit
Irms rated making capacity: 900 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for control circuit conforming to IEC 60947-5-1
rated breaking capacity: 900 A at 440 V for power circuit conforming to IEC 60947
associated fuse rating: 10 A gG for control circuit conforming to IEC 60947-5-1; 100 A gG at <= 690 V coordination type 1 for power circuit; 100 A gG at <= 690 V coordination type 2 for power circuit
power dissipation per pole: 3.7 W AC-3; 9.6 W AC-1; 3.7 W AC-3e
inrush power in VA: 140 VA cos phi 0.75 (at 20 °C); 160 VA cos phi 0.75 (at 20 °C)
hold-in power consumption in VA: 13 VA 60 Hz cos phi 0.3 (at 20 °C); 15 VA 50 Hz cos phi 0.3 (at 20 °C)
operating time: 4...19 ms opening; 12...26 ms closing
safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability: 6000000 cycles
maximum operating rate: 3600 cyc/h 60 °C
minimum switching current: 5 mA for control circuit
minimum switching voltage: 17 V for control circuit
non-overlap time: 1.5 ms on de-energisation between NC and NO contacts; 1.5 ms on energisation between NC and NO contacts
insulation resistance: > 10 MOhm for control circuit
height: 122 mm
width: 55 mm
depth: 120 mm
net weight: 1.4 kg
compatibility code: LC1D
Environment
standards: IEC 60947-4-1; EN 60947-5-1; UL 508; EN 60947-4-1; CSA C22.2 No 14; IEC 60947-5-1
product certifications: DNV; GL; RINA; CCC; GOST; BV; LROS (pending); UL; CSA; UKCA
IP degree of protection: IP2x conforming to IEC 60529; IP2x conforming to VDE 0106
ambient air temperature for operation: -40…60 °C; 60…70 °C with derating
ambient air temperature for storage: -60…80 °C
operating altitude: 0...3000 m
fire resistance: 850 °C conforming to IEC 60695-2-1
shock resistance: 10 gn contactor opened; 15 gn contactor closed
vibration resistance: 2 gn 5…300 Hz contactor opened; 4 gn 5…300 Hz contactor closed
heat dissipation: 4…5 W at 60 Hz for control circuit
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Compliant
Toxic heavy metal free: Yes
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure: ENVPEP1503009EN
Circularity Profile: ENVEOLI1503009EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free: Yes
© 2018 Alplan Kft.