Skip to main content

Schneider-Electric
CA3KN317SD

TeSys K control relay - 3 NO + 1 NC - <= 690 V - 72 V DC standard coil
Barcode: 3389110484618
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: CA3KN317SD - TeSys K control relay - 3 NO + 1 NC - <= 690 V - 72 V DC standard coil

Main

range of product: TeSys K control relay

range: TeSys

product name: TeSys CAK

product or component type: Control relay

device short name: CA3K

contactor application: Control circuit

utilisation category: AC-15; DC-13

pole contact composition: 3 NO + 1 NC

[Ue] rated operational voltage: <= 690 V <= 400 Hz

control circuit type: DC standard

[Uc] control circuit voltage: 72 V DC

Complementary

[Ith] conventional free air thermal current: 10 A (at 50 °C)

Irms rated making capacity: 110 A conforming to IEC 60947

associated fuse rating: 10 A gG conforming to IEC 60947; 10 A gG conforming to VDE 0660

[Ui] rated insulation voltage: 690 V conforming to IEC 60947; 750 V conforming to VDE 0110 group C; 690 V conforming to BS 5424; 600 V conforming to CSA C22.2 No 14

mounting support: Plate; Rail

connections - terminals: Faston terminals 1 cable(s) - busbar cross section: 6.35 mm; Faston terminals 2 cable(s) - busbar cross section: 2.8 mm

control circuit voltage limits: Operational: 0.8...1.15 Uc (at <50 °C); Drop-out: 0.1...0.75 Uc (at <50 °C)

operating time: 10 ms coil de-energisation and NO opening; 30...40 ms coil energisation and NO closing; 15 ms coil de-energisation and NC closing; 25...35 ms coil energisation and NC opening

mechanical durability: 20 Mcycles

maximum operating rate: 10000 cyc/h

immunity to microbreaks: 2 ms

inrush power in W: 3 W (at 20 °C)

hold-in power consumption in W: 3 W at 20 °C

heat dissipation: 3 W

minimum switching voltage: 17 V

minimum switching current: 5 mA

non overlap distance: 0.5 mm

insulation resistance: > 10 MOhm

height: 58 mm

width: 45 mm

depth: 57 mm

net weight: 0.225 kg

compatibility code: CA3K

Environment

standards: BS 5424; IEC 60947; NF C 63-140; VDE 0660

product certifications: CSA; UL

protective treatment: TC conforming to IEC 60068

ambient air temperature for operation: -25…50 °C

ambient air temperature for storage: -50…80 °C

operating altitude: 2000 m without derating

flame retardance: V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102

mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6; Shocks contactor open: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor closed: 15 Gn for 11 ms conforming to IEC 60068-2-27

© 2018 Alplan Kft.