XEND1641

spring return contact block - 1 OC + 1 NO - front mounting, 30 mm centres
Barcode: 3389110607765
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: XEND1641 - spring return contact block - 1 OC + 1 NO - front mounting, 30 mm centres

Main

range of product: Harmony XAC

product or component type: Contact block

component name: XEND

electrical circuit type: Control circuit

contact block application: 2-speed

contact block type: Double

type of operator: 2 spring return

product compatibility: XACM; XACB

mechanical interlocking: With mechanical interlocking

contacts type and composition: 1 C/O + 1 NO

mounting of block: Front mounting

contact operation: Slow-break; Staggered

Complementary

connections - terminals: Screw clamp terminals, 1 x 2.5 mm² with or without cable end; Screw clamp terminals, 2 x 1.5 mm² with or without cable end

mechanical durability: 1000000 cycles

contact code designation: A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A; Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A

[Ithe] conventional enclosed thermal current: 10 A

[Ui] rated insulation voltage: 400 V (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-1

maximum resistance across terminals: 25 MOhm

short-circuit protection: 10 A fuse protection by cartridge fuse type gG

rated operational power in W: 31 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 35 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C

rated operational power in VA: 140 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load); 210 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load); 640 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load); 680 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)

terminals description ISO n°1: (13-14-31-32)OF; B; (23-24)NO_CL

terminals description ISO n°2: B; (43-44-61-62)OF; (53-54)NO_CL

terminal identifier: (11-12)NC; (13-14)NO

net weight: 0.11 kg

Environment

standards: IEC 60947-5-1; CSA C22.2 No 14; EN 60947-5-1

ambient air temperature for operation: -25…70 °C

ambient air temperature for storage: -40…70 °C

vibration resistance: 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6

shock resistance: 100 gn conforming to IEC 60068-2-27

Offer Sustainability

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free: Yes

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: X

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins