Skip to main content

Schneider-Electric
RM35TM50MW

motor voltage and temperature control relay - RM35-T - 24..240 V AC/DC - 2 NO
Net discounted price 109.04 EUR
In stock: 1 pc(s)
Barcode: 3389119405287
Tariff code: 8536490099

Link to the manufacturers site: RM35TM50MW - motor voltage and temperature control relay - RM35-T - 24..240 V AC/DC - 2 NO

Main

Range of produc: Harmony Control Relays

Relay type: Motor temperature control relay

Product or component type: Motor temperature control relay

Product specific application: For 3-phase supply

Relay name: RM35TM

Relay monitored parameters: Phase sequence; Motor temperature via PTC probe; Phase failure detection

Time delay type: Fixed 0.3 s

Switching capacity in VA: 1250 VA

Measurement range: 208...480 V voltage AC; 0...20 Ohm short-circuit detection

Contacts type and composition: 2 NO

Connections - terminals: Screw connectors

[Uc] control circuit voltage: 24...240 V

[In] rated current: 5 A

Complementary

Reset time: 10000 ms output

Maximum switching voltage: 250 V AC; 250 V DC

Minimum switching current: 10 mA at 5 V DC

Maximum switching current: 5 A AC; 5 A DC

Supply voltage limits: 20.4…264 V AC; 20.4…264 V DC

Power consumption in VA: 0…4 VA at 24...240 V AC

Maximum power consumption in W: 0.5 W DC

control circuit frequency: 50...60 Hz +/- 10 %

Resistance across terminals: 602 mOhm

Output contacts: 2 NO

Nominal output current: 5 A

Measurement voltage limits: 176…528 V AC

run-up delay at power-up: 500 ms

Voltage range: 176...528 V

Response time: > 50 ms (input Y1 (contact Y1-T1) and push-button)

[Uc] control circuit voltage: <= 3.6 V of temperature control circuit (T1-T2 terminals open)

Short-circuit current: 0.007 A temperature sensing circuit (T1-T2 terminals short circuited)

Maximum resistance: 1500 Ohm for temperature sensor at 20 °C

Tripping threshold: 3100 Ohm +/- 10 % for temperature control circuit

Reset threshold: 1650 Ohm +/- 10 % for temperature control circuit

Marking: CE

Overvoltage category: III conforming to IEC 60664-1

Insulation resistance: > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5; > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1

[Ui] rated insulation voltage: 400 V conforming to IEC 60664-1

Supply frequency: 50/60 Hz +/- 10 %

Operating position: Any position without derating

Connections - terminals: Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end

Tightening torque: 0.6…1 N.m conforming to IEC 60947-1

Housing material: Self-extinguishing plastic

Local signalling: LED (green) for power ON; LED (yellow) for phase of relay (R2); LED (yellow) for temperature of relay (R1)

Mounting support: 35 mm symmetrical DIN rail conforming to IEC 60715

Electrical durability: 10000 cycles

Mechanical durability: 30000000 cycles

Operating rate: <= 360 operations/hour full load

Utilisation category: AC-12 conforming to IEC 60947-5-1; AC-13 conforming to IEC 60947-5-1; AC-14 conforming to IEC 60947-5-1; AC-15 conforming to IEC 60947-5-1; DC-12 conforming to IEC 60947-5-1; DC-13 conforming to IEC 60947-5-1

Width: 35 mm

Net weight: 0.13 kg

Compatibility code: RM3

Environment

Immunity to microbreaks: 20 ms at 20.4 V

Electromagnetic compatibility: Emission standard for industrial environments conforming to IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Immunity for industrial environments conforming to IEC 61000-6-2

Standards: IEC 60255-6; IEC 60034-11-2

product certifications: GL; UL; GOST; C-Tick; CSA

Directives: 73/23/EEC - low voltage directive; 89/336/EEC - electromagnetic compatibility

Ambient air temperature for storage: -40…70 °C

Ambient air temperature for operation: -20…50 °C

Relative humidity: 95 % at 55 °C conforming to IEC 60068-2-30

Vibration resistance: 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6; 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1

Shock resistance: 15 gn for 11 ms conforming to IEC 60255-21-1

IP degree of protection: IP20 (terminals) conforming to IEC 60529; IP30 (casing) conforming to IEC 60529

Pollution degree: 3 conforming to IEC 60664-1

Dielectric test voltage: 2 kV, 1 min AC 50 Hz

Non-dissipating shock wave: 4 kV

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 4.5 cm

Package 1 Width: 7.8 cm

Package 1 Length: 9.6 cm

Package 1 Weight: 131.0 g

Unit Type of Package 2: S03

Number of Units in Package 2: 48

Package 2 Height: 30.0 cm

Package 2 Width: 30.0 cm

Package 2 Length: 40.0 cm

Package 2 Weight: 7.0 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1504008EN

Circularity Profile: ENVEOLI1504008EN

© 2018 Alplan Kft.