RM35S0MW

speed control relay RM35-S - 24..240 V AC/DC
Net discounted price 112.51 EUR
Available when ordered (delivery time: 8 working day(s))
Barcode: 3389119405256
Tariff code: 8536490099

Link to the manufacturers site: RM35S0MW - speed control relay RM35-S - 24..240 V AC/DC

Main

Range of produc: Harmony Control Relays

Relay type: Speed control relays

Product or component type: Speed control relay

Relay name: RM35S

Relay monitored parameters: Overspeed; Underspeed

Time delay range: 0.6...60 s adjustable on energisation delay (tolerance: 0...10 % of the full scale value)

Switching capacity in VA: 1250 VA

Minimum switching current: 10 mA at 5 V DC

Maximum power consumption in VA: 5 VA AC

Measurement range: 0.05...0.5 s; 0.5...5 min; 1...10 min; 1...10 s; 0.5...5 s; 0.1...1 s; 0.1...1 min

Utilisation category: AC-12 conforming to IEC 60947-5-1; AC-13 conforming to IEC 60947-5-1; AC-14 conforming to IEC 60947-5-1; AC-15 conforming to IEC 60947-5-1; DC-12 conforming to IEC 60947-5-1; DC-13 conforming to IEC 60947-5-1; DC-14 conforming to IEC 60947-5-1

[Uc] control circuit voltage: 24...240 V

Connections - terminals: Screw connectors

Contacts type and composition: 1 C/O

[In] rated current: 5 A

Complementary

Reset time: 50 ms contact S2 in memory mode on time delay; 1 s supply Un in memory mode on time delay

Maximum switching voltage: 250 V AC/DC

Supply voltage limits: 20.4…264 V AC/DC

Maximum power consumption in W: 3 W DC

Width: 35 mm

Output contacts: 1 C/O

Contacts material: Cadmium free

Nominal output current: 5 A

run-up delay at power-up: 0.05 s

Hysteresis: 5 % of threshold

Measurement accuracy: +/- 10 % of the full scale value

Repeat accuracy: +/- 0.5 % for input and measurement circuit; +/- 0.5 % for time delay

Measurement error: +/- 0.1 %/°C with temperature variation; < +/- 1 % over the whole range with voltage variation

Input frequency: 0.0017…20 Hz

Response time: 15 ms max (on crossing the threshold)

Polarity: Reversible polarity on DC supply

Threshold setting: 10...100 %

[Us] rated supply voltage: 11.5...12.5 V

Maximum supply current for sensors: 40 mA for < 24 V AC at 25 °C; 40 mA for < 24 V DC at 25 °C; 50 mA for 24...240 V AC; 50 mA for 24...240 V DC

Impulse duration: >= 5 ms high state; >= 5 ms low state

Input compatibility: 3-wire sensor (E1) PNP or NPN, 12 V, 50 mA; NAMUR sensor (E2), 12 V, 1.5 kOhm; Voltage input (E1), 0...30 V, 9.5 kOhm, high state >= 4.5 V low state <= 1 V; Volt-free contact input (E1), 12 V, 9.5 kOhm

Marking: CE : EMC 89/336/EEC; CE : 73/23/EEC

Overvoltage category: III conforming to IEC 60664-1

Insulation resistance: > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5; > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1

[Ui] rated insulation voltage: 250 V conforming to IEC 60664-1

Control circuit voltage limits: - 15 % + 10 % Un

Supply frequency: 50/60 Hz +/- 10 %

Operating position: Any position without derating

Connections - terminals: Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end

Tightening torque: 0.6…1 N.m conforming to IEC 60947-1

Housing material: Self-extinguishing plastic

Status LED: 1 LED green for power ON; 1 LED yellow for inhibit; 1 LED yellow for relay (R)

Mounting support: 35 mm symmetrical DIN rail conforming to IEC 60715

Electrical durability: 100000 cycles

Mechanical durability: 30000000 cycles

Operating rate: <= 360 operations/hour full load

Compatibility code: RM3

Environment

Immunity to microbreaks: 50 ms

Electromagnetic compatibility: Emission standard for industrial environments conforming to IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Immunity for industrial environments conforming to NF EN/IEC 61000-6-2

Standards: NF EN 60255-6; IEC 60255-6

product certifications: C-Tick; GOST; UL; GL; CSA

Ambient air temperature for storage: -40…70 °C

ambient air temperature for operation: -20…50 °C

Relative humidity: 95 % at 55 °C conforming to IEC 60068-2-30

Vibration resistance: 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1; 1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1

Shock resistance: 15 gn for 11 ms conforming to IEC 60255-21-1

IP degree of protection: IP20 (terminals) conforming to IEC 60529; IP30 (casing) conforming to IEC 60529

Pollution degree: 3 conforming to IEC 60664-1

Dielectric test voltage: 2 kV AC 50 Hz

Non-dissipating shock wave: 4 kV

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 4.4 cm

Package 1 Width: 7.4 cm

Package 1 Length: 9.4 cm

Package 1 Weight: 130.0 g

Unit Type of Package 2: S03

Number of Units in Package 2: 48

Package 2 Height: 30.0 cm

Package 2 Width: 30.0 cm

Package 2 Length: 40.0 cm

Package 2 Weight: 7.181 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1504008EN

Circularity Profile: ENVEOLI1504008EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins