Skip to main content

Schneider-Electric
RM35JA32MW

current control relay RM35-J - range 0.15..1.5 A
Net discounted price 112.43 EUR
In stock: 1 pc(s)
Barcode: 3389119405225
Tariff code: 8536490099

Link to the manufacturers site: RM35JA32MW - current control relay RM35-J - range 0.15..1.5 A

Main

Range of produc: Harmony Control Relays

Relay type: Current control relay

Product or component type: Current control relay

Relay name: RM35JA

Relay monitored parameters: Overcurrent or undercurrent detection

Time delay type: Adjustable 1...20 s, 0 + 10 % on energisation Ti; Adjustable 0.3...30 s, 0 + 10 % on crossing the threshold Tt

Switching capacity in VA: 1250 VA

Minimum switching current: 10 mA at 5 V DC

Maximum switching current: 5 A AC/DC

Maximum power consumption in VA: 3.5 VA AC

Measurement range: 0.15...1.5 A E1-M terminals; 0.5...5 A E2-M terminals; 1.5...15 A E3-M terminals; 150 mA...15 A current

Utilisation category: AC-12 conforming to IEC 60947-5-1; AC-13 conforming to IEC 60947-5-1; AC-14 conforming to IEC 60947-5-1; AC-15 conforming to IEC 60947-5-1; DC-12 conforming to IEC 60947-5-1; DC-13 conforming to IEC 60947-5-1; DC-14 conforming to IEC 60947-5-1

Contacts type and composition: 2 C/O

Connections - terminals: Screw connectors

[Uc] control circuit voltage: 24...240 V

[In] rated current: 5 A

Complementary

Reset time: 1500 ms time delay

Maximum switching voltage: 250 V AC/DC

Supply voltage limits: 20.4…264 V AC/DC

Control circuit voltage limits: - 15 % + 10 % Un

Maximum power consumption in W: 0.6 W DC

control circuit frequency: 40...70 Hz +/- 10 %

Resistance across terminals: 0.005 Ohm at E3-M terminals; 0.015 Ohm at E2-M terminals; 0.05 Ohm at E1-M terminals

Output contacts: 2 C/O

Nominal output current: 5 A

Maximum measuring cycle: 30 ms measurement cycle as true rms value

Hysteresis: 5…50 % of threshold setting

run-up delay at power-up: 0.3 s

Measurement accuracy: +/- 10 % of the full scale value

Repeat accuracy: +/- 0.5 % for input and measurement circuit; +/- 2 % for time delay

Measurement error: 0.05 %/°C with temperature variation; 1 by volt over the whole range with voltage variation

Polarity: No DC

Threshold setting: 10...100 %

Marking: CE : EMC 89/336/EEC; CE : 73/23/EEC

Overvoltage category: III conforming to IEC 60664-1

Insulation resistance: > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5; > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1

[Ui] rated insulation voltage: 250 V conforming to IEC 60664-1

Operating position: Any position without derating

Connections - terminals: Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end

Tightening torque: 0.6…1 N.m conforming to IEC 60947-1

Housing material: Self-extinguishing plastic

Local signalling: LED (green) for power ON; LED (yellow) for relay ON

Mounting support: 35 mm symmetrical DIN rail conforming to IEC 60715

Electrical durability: 100000 cycles

Mechanical durability: 30000000 cycles

Operating rate: <= 360 operations/hour full load

Safety reliability data: MTTFd = 296.8 years; B10d = 270000

Contacts material: Cadmium free

Width: 35 mm

Net weight: 0.13 kg

Functionality: Overcurrent or undercurrent in window mode

Compatibility code: RM3

Environment

Immunity to microbreaks: 50 ms

Electromagnetic compatibility: Emission standard for industrial environments conforming to IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Immunity for industrial environments conforming to NF EN/IEC 61000-6-2

Standards: IEC 60255-6

product certifications: GL; UL; GOST; C-Tick; CSA

Ambient air temperature for storage: -40…70 °C

Ambient air temperature for operation: -20…50 °C

Relative humidity: 95 % at 55 °C conforming to IEC 60068-2-30

Vibration resistance: 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6; 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1

Shock resistance: 15 gn for 11 ms conforming to IEC 60255-21-1

IP degree of protection: IP20 (terminals) conforming to IEC 60529; IP30 (casing) conforming to IEC 60529

Pollution degree: 3 conforming to IEC 60664-1

Dielectric test voltage: 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5; 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1

Non-dissipating shock wave: 4 kV conforming to IEC 60255-5; 4 kV conforming to IEC 60664-1; 4 kV conforming to IEC 61000-4-5

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 4.500 cm

Package 1 Width: 8.000 cm

Package 1 Length: 9.500 cm

Package 1 Weight: 145.000 g

Unit Type of Package 2: S03

Number of Units in Package 2: 48

Package 2 Height: 30.000 cm

Package 2 Width: 30.000 cm

Package 2 Length: 40.000 cm

Package 2 Weight: 7.735 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1504008EN

Circularity Profile: ENVEOLI1504008EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.