Schneider-Electric
RM35ATR5MW
Tariff code: 8536490099
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: RM35ATR5MW - temperature control relay RM35-A - 24..240 V AC/DC - 2 NO
Main
Range of product: Harmony Control Relays
Product or component type: Temperature control relay
Relay type: Temperature control relays
Product specific application: For elevator machine rooms and 3-phase supplies
Relay name: RM35AT
Relay monitored parameters: Overtemperature: 34...46°C; Undertemperature: -1...11°C
Time delay range: 0.1...10 s adjustable delay (tolerance: 0...10 % of the full scale value)
Switching capacity in VA: 1250 VA
Minimum switching current: 10 mA at 5 V DC
Maximum power consumption in VA: 3.5 VA AC
Utilisation category: AC-12 conforming to IEC 60947-5-1; AC-13 conforming to IEC 60947-5-1; AC-14 conforming to IEC 60947-5-1; AC-15 conforming to IEC 60947-5-1; DC-12 conforming to IEC 60947-5-1; DC-13 conforming to IEC 60947-5-1; DC-14 conforming to IEC 60947-5-1
[Uc] control circuit voltage: 24...240 V
Connections - terminals: Screw connectors
Contacts type and composition: 2 NO
[In] rated current: 5 A
Complementary
Reset time: 8 s
Maximum switching voltage: 250 V AC/DC
[Us] rated supply voltage: 24...240 V AC/DC
[Us] rated supply voltage: 24...240 V AC/DC
Supply voltage limits: 20.4…264 V AC; 21.6…264 V DC
Maximum power consumption in W: 0.6 W DC
Resistance across terminals: 1.33 kOhm at temperature
Width: 35 mm
Output contacts: 2 NO
Contacts material: Cadmium free
nominal output current: 5 A
Run-up delay at power-up: 0.2 s
measurement accuracy: +/- 2 °C
Response time: <= 3.5 s + Tt (in case of temperature fault); <= 3.5 s (on disappearance of fault)
Temperature probe type: Pt 100 - 3-wire
Installed device: Pt 100 probe cable length <= 10 m
Marking: CE : EMC 89/336/EEC; CE : 73/23/EEC
Overvoltage category: III conforming to IEC 60664-1
Insulation resistance: > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5; > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1
[Ui] rated insulation voltage: 250 V conforming to IEC 60664-1
Control circuit voltage limits: - 10 % + 10 % Un DC; - 15 % + 10 % Un AC
Supply frequency: 50/60 Hz +/- 10 %
Insulation: Galvanic insulation between supply and measurement
Operating position: Any position without derating
Connections - terminals: Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque: 0.6…1 N.m conforming to IEC 60947-1
Housing material: Self-extinguishing plastic
Status LED: 1 LED green for power ON; 1 LED yellow for correct temperature (high R1); 1 LED yellow for correct temperature (low R2)
Mounting support: 35 mm symmetrical DIN rail conforming to EN/IEC 60715
Electrical durability: 100000 cycles
Mechanical durability: 30000000 cycles
Operating rate: <= 360 operations/hour full load
Compatibility code: RM3
Environment
Immunity to microbreaks: 10 ms
Electromagnetic compatibility: Emission standard for industrial environments conforming to EN/IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3; Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Standards: IEC 60255-6; NF EN 60255-6
Product certifications: GL; GOST; C-Tick; CSA; UL
Ambient air temperature for storage: -40…70 °C
Ambient air temperature for operation: -20…50 °C
Vibration resistance: 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1; 1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
Shock resistance: 15 gn for 11 ms conforming to IEC 60255-21-1
IP degree of protection: IP20 (terminals) conforming to IEC 60529; IP30 (casing) conforming to IEC 60529
Pollution degree: 3 conforming to IEC 60664-1
Dielectric test voltage: 2 kV, 1 min AC 50 Hz
non-dissipating shock wave: 4 kV
Packing Units
Unit Type of Package 1: Db
Number of Units in Package 1: 1
Package 1 Height: 7.52 cm
Package 1 Width: 4.4 cm
Package 1 Length: 9.7 cm
Package 1 Weight: 131.0 g
Unit Type of Package 2: Doboz
Number of Units in Package 2: 48
Package 2 Height: 30.0 cm
Package 2 Width: 30.0 cm
Package 2 Length: 40.0 cm
Package 2 Weight: 7.001 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP1504008EN
Circularity Profile: ENVEOLI1504008EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.