Skip to main content

Schneider-Electric
LU2MB0BL

reverser block LU2M - 32 A - 24 V DC - direct mounting
Net discounted price 189.98 EUR
Available when ordered (delivery time: 13 working day(s))
Barcode: 3389110363777
Tariff code: 8536201090

Link to the manufacturers site: LU2MB0BL - reverser block LU2M - 32 A - 24 V DC - direct mounting

Main

Range of produc: TeSys Ultra

Range: TeSys

Device short name: LU2MB

Product or component type: Reverser block

Device mounting: Direct mounting

Device application: Motor control

[Ie] rated operational current: 38 A

[Uc] control circuit voltage: 24 V DC

Current consumption: 120 mA at 24 V DC I maximum while closing; 120 mA at 24 V DC I rms sealed

Complementary

[Ue] rated operational voltage: 690 V AC power circuit

Network frequency: 40...60 Hz

Inrush restraint duration: 25 ms AC; 15 ms DC

Operating time: 150 ms with change of direction; 75 ms without change of direction

Standards: EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier

product certifications: CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine

[Ui] rated insulation voltage: 690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2

Fixing mode: Plug-in

Connections - terminals: Control circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² (external diameter: 3 mm) flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² (external diameter: 3 mm) flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² (external diameter: 3 mm) rigid; Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² (external diameter: 3 mm) flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² (external diameter: 3 mm) flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² (external diameter: 3 mm) rigid; Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² (external diameter: 4 mm) rigid; Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² (external diameter: 4 mm) flexible with cable end; Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² (external diameter: 4 mm) flexible without cable end; Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² (external diameter: 4 mm) flexible with cable end; Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² (external diameter: 4 mm) rigid; Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² (external diameter: 4 mm) flexible without cable end

Tightening torque: Control circuit: 0.8…1.2 N.m flat screwdriver 5 mm; Control circuit: 0.8…1.2 N.m Philips No 2 screwdriver 5 mm; Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm

Width: 45 mm

height: 80 mm

Depth: 105 mm

Net weight: 0.4 kg

Compatibility code: LU2MB

Environment

IP degree of protection: IP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone)

Protective treatment: TH conforming to IEC 60068

Ambient air temperature for operation: -25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD

Ambient air temperature for storage: -40…85 °C

Fire resistance: 960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12

Operating altitude: 2000 m

Shock resistance: 10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27

Vibration resistance: 2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27

Resistance to electrostatic discharge: 8 kV level 3, in open air conforming to IEC 61000-4-2; 8 kV level 4, on contact conforming to IEC 61000-4-2

Resistance to radiated fields: 10 V/m level 3 conforming to IEC 61000-4-3

Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4

Immunity to radioelectric fields: 10 V conforming to IEC 61000-4-6

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 13 cm

Package 1 Width: 5.7 cm

Package 1 Length: 9.5 cm

Package 1 Weight: 393 g

Unit Type of Package 2: S02

Number of Units in Package 2: 12

Package 2 Height: 15 cm

Package 2 Width: 30 cm

Package 2 Length: 40 cm

Package 2 Weight: 4.999 kg

Offer Sustainability

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant with Exemptions

Mercury free: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

RoHS exemption information: Yes

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.