Skip to main content

Schneider-Electric
LC1D1506F7

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 110 V AC 50/60 Hz coil
Net discounted price 366.97 EUR
Available when ordered (delivery time: 6 working day(s))
Barcode: 3389110499162
Tariff code: 8536490099

Link to the manufacturers site: LC1D1506F7 - TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 110 V AC 50/60 Hz coil

Main

Range: TeSys

Range of produc: TeSys Deca

Product or component type: Contactor

Device short name: LC1D

contactor application: Motor control; Resistive load

utilisation category: AC-1; AC-4; AC-3; AC-3e

Poles description: 3P

[Ue] rated operational voltage: Power circuit: <= 1000 V AC 25...400 Hz; Power circuit: <= 300 V DC

[Ie] rated operational current: 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit; 150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

[Uc] control circuit voltage: 110 V AC 50/60 Hz

Complementary

Motor power kW: 40 kW at 220...230 V AC 50/60 Hz (AC-3); 75 kW at 380...400 V AC 50/60 Hz (AC-3); 80 kW at 415...440 V AC 50/60 Hz (AC-3); 90 kW at 500 V AC 50/60 Hz (AC-3); 100 kW at 660...690 V AC 50/60 Hz (AC-3); 75 kW at 1000 V AC 50/60 Hz (AC-3); 22 kW at 400 V AC 50/60 Hz (AC-4); 40 kW at 220...230 V AC 50/60 Hz (AC-3e); 75 kW at 380...400 V AC 50/60 Hz (AC-3e); 80 kW at 415...440 V AC 50/60 Hz (AC-3e); 90 kW at 500 V AC 50/60 Hz (AC-3e); 100 kW at 660...690 V AC 50/60 Hz (AC-3e); 75 kW at 1000 V AC 50/60 Hz (AC-3e)

Motor power hp: 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors

Compatibility code: LC1D

Pole contact composition: 3 NO

Contact compatibility: M13

Protective cover: With

[Ith] conventional free air thermal current: 200 A (at 60 °C) for power circuit

Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1660 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity: 1400 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current: 250 A 40 °C - 10 min for power circuit; 580 A 40 °C - 1 min for power circuit; 1200 A 40 °C - 10 s for power circuit; 1400 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit

Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1; 315 A gG at <= 690 V coordination type 1 for power circuit; 250 A gG at <= 690 V coordination type 2 for power circuit

Average impedance: 0.6 mOhm - Ith 200 A 50 Hz for power circuit

Power dissipation per pole: 24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e

[Ui] rated insulation voltage: Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified

Overvoltage category: III

Pollution degree: 3

[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947

Safety reliability level: B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Mechanical durability: 8 Mcycles

Electrical durability: 0.85 Mcycles 150 A AC-3 at Ue <= 440 V; 1 Mcycles 200 A AC-1 at Ue <= 440 V; 0.85 Mcycles 150 A AC-3e at Ue <= 440 V

Control circuit type: AC at 50/60 Hz

Coil technology: Built-in bidirectional peak limiting diode suppressor

Control circuit voltage limits: 0.3...0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.15 Uc (-40…55 °C):operational AC 50/60 Hz; 1...1.15 Uc (55…70 °C):operational AC 50/60 Hz

Inrush power in VA: 280…350 VA 60 Hz cos phi 0.9 (at 20 °C); 280…350 VA 50 Hz cos phi 0.9 (at 20 °C)

Hold-in power consumption in VA: 2…18 VA 60 Hz cos phi 0.9 (at 20 °C); 2…18 VA 50 Hz cos phi 0.9 (at 20 °C)

Heat dissipation: 3…4.5 W at 50/60 Hz

Operating time: 20...35 ms closing; 40...75 ms opening

Maximum operating rate: 1200 cyc/h 60 °C

Connections - terminals: Control circuit: lugs-ring terminals - external diameter: 8 mm; Power circuit: lugs-ring terminals - external diameter: 25 mm; Power circuit: bars 1 - busbar cross section: 5 x 25 mm

Tightening torque: Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5; Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5; Power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8; Power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8; Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5

Auxiliary contact composition: 1 NO + 1 NC

Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency: 25...400 Hz

Minimum switching voltage: 17 V for signalling circuit

Minimum switching current: 5 mA for signalling circuit

Insulation resistance: > 10 MOhm for signalling circuit

Non-overlap time: 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact

mounting support: Rail; Plate

Environment

Standards: CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 508

product certifications: RINA; BV; CSA; LROS (Lloyds register of shipping); GOST; UL; GL; DNV; CCC; UKCA; CE

IP degree of protection: IP20 front face conforming to IEC 60529

Protective treatment: TH conforming to IEC 60068-2-30

Climatic withstand: conforming to IACS E10 exposure to damp heat

Permissible ambient air temperature around the device: -40…60 °C; 60…70 °C with derating

Operating altitude: 0...3000 m

Fire resistance: 850 °C conforming to IEC 60695-2-1

Flame retardance: V1 conforming to UL 94

Mechanical robustness: Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (6 Gn for 11 ms)

height: 158 mm

Width: 120 mm

Depth: 136 mm

Net weight: 2.5 kg

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 19.000 cm

Package 1 Width: 17.500 cm

Package 1 Length: 21.500 cm

Package 1 Weight: 2.214 kg

Unit Type of Package 2: P06

Number of Units in Package 2: 27

Package 2 Height: 75.000 cm

Package 2 Width: 60.000 cm

Package 2 Length: 80.000 cm

Package 2 Weight: 72.778 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant with Exemptions

Mercury free: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP060301EN

Circularity Profile: ENVEOLI100405

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free: Yes

© 2018 Alplan Kft.