Skip to main content

Schneider-Electric
XY2CE1A170

TRIP WIRE SWITCH
Barcode: 3389118133228
Tariff code: 8536508090

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: XY2CE1A170 - TRIP WIRE SWITCH

Main

range of product: Telemecanique Emergency stop rope pull switches XY2C

product or component type: Latching emergency stop rope pull switch

device short name: XY2CE

overvoltage category: Class I conforming to EN/IEC 61140; Class I conforming to NF C 20-030

Complementary

local signalling: Without pilot light

body material: Zamak

cover material: Stainless steel

reset: By flush push-button

contacts type and composition: 1 NC + 1 NO

contact operation: Slow-break

trigger cable anchor point: RH side

connections - terminals: Screw clamp terminal, 1 x 0.5...2 x 1.5 mm²

tightening torque: 0.8…1.2 N.m

cable entry number: 3 plain hole for Pg 13.5 or ISO M20 cable gland

safety level: Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1; Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1; Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508

safety reliability data: B10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear

marking: CE

mechanical durability: 60000 cycles

distance between cable supports: 5 m

[Ie] rated operational current: 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A; 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A

[Ithe] conventional enclosed thermal current: 10 A

[Ui] rated insulation voltage: 500 V (pollution degree 3) conforming to EN/IEC 60947-1; 300 V conforming to UL 508; 300 V conforming to CSA C22.2 No 14

[Uimp] rated impulse withstand voltage: 6 kV conforming to EN/IEC 60947-1

positive opening: With conforming to EN/IEC 60947-5-1

maximum resistance across terminals: 25 MOhm conforming to EN/IEC 60255-7 category 3; 25 MOhm conforming to NF C 93-050 method A

short-circuit protection: 10 A cartridge fuse type gG conforming to EN/IEC 60269

terminals description ISO n°1: (13-14)NO; (21-22)NC

net weight: 1.45 kg

compatibility code: XY2CE

Environment

standards: Machinery directive 2006/42/EC; UL 508; EN/IEC 60204-1; Work equipment directive 2009/104/EC; EN/IEC 60947-5-5; CSA C22.2 No 14; EN/IEC 60947-5-1; EN/ISO 13850

product certifications: UL category NISD emergency stop devices; CSA; CCC

protective treatment: TC

ambient air temperature for operation: -25…70 °C

ambient air temperature for storage: -40…70 °C

vibration resistance: 10 gn (f= 10…300 Hz) conforming to EN/IEC 60068-2-6

shock resistance: 50 gn 11 ms conforming to EN/IEC 60068-2-27

IP degree of protection: IP66 conforming to IEC 60529

Packing Units

Number of Units in Package 1: 1

Number of Units in Package 2: 1

Package 1 Height: 15 cm

Package 1 Length: 40 cm

Package 1 Weight: 1.45 kg

Package 1 Width: 30 cm

Package 2 Height: 15 cm

Package 2 Length: 40 cm

Package 2 Weight: 1.5 kg

Package 2 Width: 30 cm

Unit Type of Package 1: PCE

Unit Type of Package 2: CAR

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP111159EN

© 2018 Alplan Kft.