Skip to main content

Schneider-Electric
XCKP2502G11

limit switch XCKP - steel roller plunger - 1NC+1NO - slow - Pg11
Barcode: 3389110316810
Tariff code: 8536508090

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: XCKP2502G11 - limit switch XCKP - steel roller plunger - 1NC+1NO - slow - Pg11

Main

Range of produc: Telemecanique Limit switches XC Standard

Series name: Standard format

Product or component type: Limit switch

Device short name: XCKP

Sensor design: Compact form C conforming to CENELEC EN 50047

Body type: Fixed

Head type: Plunger head

Material: Plastic

body material: Plastic

Head material: Zamak

Fixing mode: By the body

Movement of operating head: Linear

Type of operator: Spring return roller plunger metal

Type of approach: Lateral approach, 2 directions

Number of poles: 2

Contacts type and composition: 1 NC + 1 NO

contact operation: Slow-break, break before make

Complementary

Switch actuation: By 30° cam

Electrical connection: Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²

Cable entry: 1 entry tapped for Pg 11 cable gland

Contacts insulation form: Zb

Positive opening: With

Positive opening minimum force: 36 N

Minimum force for tripping: 12 N

Maximum actuation speed: 0.5 m/s

Repeat accuracy: 0.1 mm on the tripping points with 1 million operating cycles

Contact code designation: A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A; Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A

[Ui] rated insulation voltage: 300 V conforming to UL 508; 500 V (pollution degree 3) conforming to IEC 60947-1; 300 V conforming to CSA C22.2 No 14

Maximum resistance across terminals: 25 MOhm conforming to IEC 60255-7 category 3

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60664; 6 kV conforming to IEC 60947-1

Short-circuit protection: 10 A cartridge fuse, type gG

Electrical durability: 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

Mechanical durability: 10000000 cycles

Width: 31 mm

height: 65 mm

Depth: 30 mm

Net weight: 0.095 kg

Terminals description ISO n°1: (13-14)NO; (21-22)NC

device presentation: Complete product

Compatibility code: XCKP

Specific application: Compact variable

Environment

Shock resistance: 50 gn for 11 ms conforming to IEC 60068-2-27

Vibration resistance: 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6

IP degree of protection: IP66 conforming to IEC 60529; IP67 conforming to IEC 60529

IK degree of protection: IK04 conforming to EN 50102

Electrical shock protection class: Class II conforming to IEC 61140; Class II conforming to NF C 20-030

ambient air temperature for operation: -25…70 °C

Ambient air temperature for storage: -40…70 °C

Protective treatment: TC

product certifications: CCC; UL; CSA

Standards: CSA C22.2 No 14; EN 60947-5-1; UL 508; IEC 60947-5-1; EN 60204-1; IEC 60204-1

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 3.8 cm

Package 1 Width: 3.8 cm

Package 1 Length: 10.0 cm

Package 1 Weight: 79.0 g

Unit Type of Package 2: S02

Number of Units in Package 2: 77

Package 2 Height: 15.0 cm

Package 2 Width: 30.0 cm

Package 2 Length: 40.0 cm

Package 2 Weight: 6.478 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP110606EN

Circularity Profile: ENVEOLI110603EN

© 2018 Alplan Kft.