Schneider-Electric
XCKJ10541A
Tariff code: 8536508090
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: XCKJ10541A - limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - 7/8"
Main
Range of produc: Telemecanique Limit switches XC Standard
Series name: Standard format
Product or component type: Limit switch
Device short name: XCKJ
Sensor design: -
Body type: Fixed
Head type: Rotary head
Material: Metal
body material: Zamak
Head material: Zamak
Fixing mode: By the body
Movement of operating head: Rotary
Type of operator: Spring return roller lever thermoplastic variable length
Type of approach: Lateral approach, 1 or 2 programmable direction
Number of poles: 2
Contacts type and composition: 1 NC + 1 NO
contact operation: Snap action
Complementary
Switch actuation: By 30° cam
Electrical connection: Male connector 7/8", 5 pins
Contacts insulation form: Zb
Number of steps: 1
Positive opening: Without
Minimum torque for tripping: 0.25 N.m
Maximum actuation speed: 1.5 m/s
[Ie] rated operational current: 0.27 A at 250 V, DC-13 conforming to EN/IEC 60947-5-1 appendix A; 3 A at 240 V, AC-15 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current: 6 A
[Ui] rated insulation voltage: 300 V conforming to UL 508; 300 V conforming to CSA C22.2 No 14; 250 V (pollution degree 3) conforming to IEC 60947-1
Maximum resistance across terminals: 25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60664; 6 kV conforming to IEC 60947-1
Short-circuit protection: 6 A cartridge fuse, type gG
Electrical durability: 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability: 30000000 cycles
Width: 40 mm
height: 94 mm
Depth: 44 mm
Net weight: 0.485 kg
Terminals description ISO n°1: (13-14)NO; (21-22)NC
Compatibility code: XCKJ
Specific application: Industrial
Environment
Shock resistance: 50 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance: 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP degree of protection: IP66 conforming to IEC 60529
IK degree of protection: IK07 conforming to EN 50102
Overvoltage category: Class I conforming to IEC 61140; Class I conforming to NF C 20-030
ambient air temperature for operation: -25…70 °C
Ambient air temperature for storage: -40…70 °C
Protective treatment: TH
product certifications: CCC; CSA; UL
Standards: IEC 60947-5-1; UL 508; CENELEC EN 50041; EN 60204-1; IEC 60204-1; EN 60947-5-1; CSA C22.2 No 14
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 7.0 cm
Package 1 Width: 8.7 cm
Package 1 Length: 19.6 cm
Package 1 Weight: 543.0 g
Unit Type of Package 2: S02
Number of Units in Package 2: 18
Package 2 Height: 15 cm
Package 2 Width: 30 cm
Package 2 Length: 40 cm
Package 2 Weight: 10.229 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP110614EN
Circularity Profile: N/A
© 2018 Alplan Kft.