Schneider-Electric
XCKD2102N12
Tariff code: 8536508090
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: XCKD2102N12 - limit switch XCKD - steel roller plunger - 1NC+1NO - snap - 1/2NPT
Main
Range of produc: Telemecanique Limit switches XC Standard
Series name: Standard format
Product or component type: Limit switch
Device short name: XCKD
Sensor design: Compact form C conforming to CENELEC EN 50047
Body type: Fixed
Head type: Plunger head
Material: Metal
body material: Zamak
Head material: Zamak
Fixing mode: By the body
Movement of operating head: Linear
Type of operator: Spring return roller plunger metal
Type of approach: Lateral approach, 2 directions
Number of poles: 2
Contacts type and composition: 1 NC + 1 NO
contact operation: Snap action
Complementary
Switch actuation: By 30° cam
Electrical connection: Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Cable entry: 1 entry tapped for 1/2" NPT cable gland
Contacts insulation form: Zb
Positive opening: With
Positive opening minimum force: 36 N
Minimum force for tripping: 12 N
Maximum actuation speed: 0.5 m/s
Contact code designation: A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A; Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
[Ui] rated insulation voltage: 300 V conforming to UL 508; 500 V (pollution degree 3) conforming to IEC 60947-1; 300 V conforming to CSA C22.2 No 14
Maximum resistance across terminals: 25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60664; 6 kV conforming to IEC 60947-1
Short-circuit protection: 10 A cartridge fuse, type gG
Electrical durability: 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability: 10000000 cycles
Terminals description ISO n°1: (13-14)NO; (21-22)NC
device presentation: Complete product
Compatibility code: XCKD
Specific application: Compact variable
Environment
Shock resistance: 50 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance: 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IK degree of protection: IK06 conforming to EN 50102
Electrical shock protection class: Class I conforming to IEC 61140; Class I conforming to NF C 20-030
ambient air temperature for operation: -25…70 °C
Ambient air temperature for storage: -40…70 °C
Protective treatment: TC
product certifications: CCC; CSA; UL
Standards: IEC 60204-1; EN 60204-1; UL 508; IEC 60947-5-1; EN 60947-5-1; CSA C22.2 No 14
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 10.5 cm
Package 1 Width: 3.3 cm
Package 1 Length: 4.3 cm
Package 1 Weight: 199.0 g
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP110614EN
Circularity Profile: N/A
© 2018 Alplan Kft.