Skip to main content

Schneider-Electric
VPL12N

Power Factor controller - VarPlus Logic - VPL 12
Net discounted price 820.88 EUR
Available when ordered (delivery time: 8 working day(s))
Barcode: 3606480800115
Tariff code: 8537109899

Link to the manufacturers site: VPL12N - Power Factor controller - VarPlus Logic - VPL 12

Main

Range: PowerLogic

Product name: PowerLogic PFC Controller

Device short name: VPL12

product or component type: Power factor controller

Complementary

Number of step output contacts: 12

[Us] rated supply voltage: 90...550 V AC; <= 999 kV AC with external VT

Measurement current: 0…5 A

Measurement voltage: 90…550 V AC 50/60 Hz

Operating mode: Manual or automatic

Number of quadrant operation for generator application: 4

Device connection: Communication protocol: Modbus interface: RS485

Input function: Switch: 1 x dry contact

Colour code: Front: dark grey RAL 7016

Display type: Backlit LCD

Display size: 56 x 25 mm

Function available: Manual programming; Automatic initialisation; Automatic detection; Advanced programming (expert); Any step sequence

Metering type: Power factor and displacement PF (signed, four quadrant); Total current harmonic distortion THD (I); Power factor average over lifetime; Temperature maximum; Phase current I1, I2, I3 RMS on load; Active power P, P1, P2, P3 on load; Reactive power Q, Q1, Q2, Q3 on load; Apparent power S, S1, S2, S3 on load; Voltage U21, U32, U13, V1, V2, V3 on load

Type of measurement: Capacitor current overload Irms/I1; Individual voltage harmonic; Power factor; Operating time; Cos φ; Ambient temperature inside the cubicle; Tan φ

Information displayed: Number of switching cycles per step; Individual step size in kVAr; Remaining step capacity in %

Type of alarms: Step power loss (< 75 %) / Action: message and alarm contact + step blocked; Step faulty / Action: message and alarm contact + step blocked; High current (> 6 A CT) / Action: message and alarm contact; Hunting (unstable regulation) / Action: message and alarm contact + step blocked; Low current (< 15 mA CT) / Action: message and alarm contact; Overcompensation / Action: message and alarm contact; Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off; Overtemperature (50 °C) / Action: message and alarm contact + step switched off; Overtemperature (30 °C) / Action: fan switch; Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped; Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off

Data recording: 5 alarms

Service life in hours: 100000 h without maintenance

Mechanical durability: 65000 cycles without maintenance

input type: Phase to phase; Phase to neutral; Insensitive to CT polarity; Insensitive to phase rotation polarity; Current input CT...X/5 A and X/1 A

Output type: Control relay: 0.2 A 110 V DC; Control relay: 1 A 48 V DC; Control relay: 2 A 400 V AC 50/60 Hz; Control relay: 1 A 24 V DC; Control relay: 5 A 250 V AC 50/60 Hz; Control relay: 5 A 120 V AC 50/60 Hz; Fan: 5 A 250 V AC 50/60 Hz; Fan: 1 A 48 V DC; Alarm relay: 5 A 250 V AC 50/60 Hz; Alarm relay: 1 A 48 V DC

Current of common: 10 A

settings operating mode: Automatic; Manual

Type of setting: Choice of stepping programs: auto; Choice of stepping programs: LIFO; Choice of stepping programs: linear; Delay between 2 successive switch on the same step: 5...1200 s; Step configuration programming: auto; Step configuration programming: off; Step configuration programming: fixed; Target cos phi: 0.7 inductive...0.7 capacitive; Target cos phi: dual cos φ

Measurement accuracy: Voltage +/- 1 %; Current +/- 1 %; Frequency +/- 1 %; Energy (P,Q,S) +/- 2 %; Cos φ +/- 2 %; Total voltage harmonic distortion THD (U) +/- 2 %; Individual voltage harmonic +/- 3 %; Temperature +/- 3 °C

Time delay range: 1...6500 s (on reconnection); 1...6500 s (on response)

Provided equipment: User manual

Mounting mode: Flush-mounted

Mounting support: Panel - thickness: 1…3 mm

Mounting location: In cabinet

cut-out dimensions: 138 x 138 mm

Height: 144 mm

Width: 144 mm

Depth: 58 mm

Net weight: 0.6 kg

Compatibility code: VPL 12

Environment

Standards: IEC 61000-6-4; UL 61010-1; EN 61010-1; IEC 61000-6-2; IEC 61326-1

Product certifications: EAC; NRTL; cNRTL; CE

IP degree of protection: Front face: IP41; Rear face: IP20

Operating altitude: <= 2000 m

Ambient air temperature for operation: -20…60 °C

Ambient air temperature for storage: -40…85 °C

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 9.200 cm

Package 1 Width: 17.700 cm

Package 1 Length: 18.400 cm

Package 1 Weight: 724.000 g

Unit Type of Package 2: S03

Number of Units in Package 2: 8

Package 2 Height: 30.000 cm

Package 2 Width: 30.000 cm

Package 2 Length: 40.000 cm

Package 2 Weight: 6.155 kg

Unit Type of Package 3: P06

Number of Units in Package 3: 64

Package 3 Height: 75.000 cm

Package 3 Width: 60.000 cm

Package 3 Length: 80.000 cm

Package 3 Weight: 58.408 kg

Offer Sustainability

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Compliant with Exemptions

Mercury free: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure: ENVPEP1509016_V1

Circularity Profile: ENVEOLI1509016EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.