Schneider-Electric
VPL12N
Tariff code: 8537109899
Link to the manufacturers site: VPL12N - Power Factor controller - VarPlus Logic - VPL 12
Main
Range: PowerLogic
Product name: PowerLogic PFC Controller
Device short name: VPL12
product or component type: Power factor controller
Complementary
Number of step output contacts: 12
[Us] rated supply voltage: 90...550 V AC; <= 999 kV AC with external VT
Measurement current: 0…5 A
Measurement voltage: 90…550 V AC 50/60 Hz
Operating mode: Manual or automatic
Number of quadrant operation for generator application: 4
Device connection: Communication protocol: Modbus interface: RS485
Input function: Switch: 1 x dry contact
Colour code: Front: dark grey RAL 7016
Display type: Backlit LCD
Display size: 56 x 25 mm
Function available: Manual programming; Automatic initialisation; Automatic detection; Advanced programming (expert); Any step sequence
Metering type: Power factor and displacement PF (signed, four quadrant); Total current harmonic distortion THD (I); Power factor average over lifetime; Temperature maximum; Phase current I1, I2, I3 RMS on load; Active power P, P1, P2, P3 on load; Reactive power Q, Q1, Q2, Q3 on load; Apparent power S, S1, S2, S3 on load; Voltage U21, U32, U13, V1, V2, V3 on load
Type of measurement: Capacitor current overload Irms/I1; Individual voltage harmonic; Power factor; Operating time; Cos φ; Ambient temperature inside the cubicle; Tan φ
Information displayed: Number of switching cycles per step; Individual step size in kVAr; Remaining step capacity in %
Type of alarms: Step power loss (< 75 %) / Action: message and alarm contact + step blocked; Step faulty / Action: message and alarm contact + step blocked; High current (> 6 A CT) / Action: message and alarm contact; Hunting (unstable regulation) / Action: message and alarm contact + step blocked; Low current (< 15 mA CT) / Action: message and alarm contact; Overcompensation / Action: message and alarm contact; Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off; Overtemperature (50 °C) / Action: message and alarm contact + step switched off; Overtemperature (30 °C) / Action: fan switch; Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped; Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
Data recording: 5 alarms
Service life in hours: 100000 h without maintenance
Mechanical durability: 65000 cycles without maintenance
input type: Phase to phase; Phase to neutral; Insensitive to CT polarity; Insensitive to phase rotation polarity; Current input CT...X/5 A and X/1 A
Output type: Control relay: 0.2 A 110 V DC; Control relay: 1 A 48 V DC; Control relay: 2 A 400 V AC 50/60 Hz; Control relay: 1 A 24 V DC; Control relay: 5 A 250 V AC 50/60 Hz; Control relay: 5 A 120 V AC 50/60 Hz; Fan: 5 A 250 V AC 50/60 Hz; Fan: 1 A 48 V DC; Alarm relay: 5 A 250 V AC 50/60 Hz; Alarm relay: 1 A 48 V DC
Current of common: 10 A
settings operating mode: Automatic; Manual
Type of setting: Choice of stepping programs: auto; Choice of stepping programs: LIFO; Choice of stepping programs: linear; Delay between 2 successive switch on the same step: 5...1200 s; Step configuration programming: auto; Step configuration programming: off; Step configuration programming: fixed; Target cos phi: 0.7 inductive...0.7 capacitive; Target cos phi: dual cos φ
Measurement accuracy: Voltage +/- 1 %; Current +/- 1 %; Frequency +/- 1 %; Energy (P,Q,S) +/- 2 %; Cos φ +/- 2 %; Total voltage harmonic distortion THD (U) +/- 2 %; Individual voltage harmonic +/- 3 %; Temperature +/- 3 °C
Time delay range: 1...6500 s (on reconnection); 1...6500 s (on response)
Provided equipment: User manual
Mounting mode: Flush-mounted
Mounting support: Panel - thickness: 1…3 mm
Mounting location: In cabinet
cut-out dimensions: 138 x 138 mm
Height: 144 mm
Width: 144 mm
Depth: 58 mm
Net weight: 0.6 kg
Compatibility code: VPL 12
Environment
Standards: IEC 61000-6-4; UL 61010-1; EN 61010-1; IEC 61000-6-2; IEC 61326-1
Product certifications: EAC; NRTL; cNRTL; CE
IP degree of protection: Front face: IP41; Rear face: IP20
Operating altitude: <= 2000 m
Ambient air temperature for operation: -20…60 °C
Ambient air temperature for storage: -40…85 °C
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 9.200 cm
Package 1 Width: 17.700 cm
Package 1 Length: 18.400 cm
Package 1 Weight: 724.000 g
Unit Type of Package 2: S03
Number of Units in Package 2: 8
Package 2 Height: 30.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 6.155 kg
Unit Type of Package 3: P06
Number of Units in Package 3: 64
Package 3 Height: 75.000 cm
Package 3 Width: 60.000 cm
Package 3 Length: 80.000 cm
Package 3 Weight: 58.408 kg
Offer Sustainability
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Compliant with Exemptions
Mercury free: Yes
China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure: ENVPEP1509016_V1
Circularity Profile: ENVEOLI1509016EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins