Skip to main content

Schneider-Electric
TM221CE24R

controller M221 24 IO relay Ethernet
Net discounted price 382.18 EUR
Available when ordered (delivery time: 131 working day(s))
Barcode: 3606480648779
Tariff code: 8537109199

Link to the manufacturers site: TM221CE24R - controller M221 24 IO relay Ethernet

Main

Range of produc: Modicon M221

Product or component type: Logic controller

[Us] rated supply voltage: 100...240 V AC

Discrete input number: 14, discrete input conforming to IEC 61131-2 Type 1

Analogue input number: 2 at 0...10 V

Discrete output type: Relay normally open

Discrete output number: 10 relay

Discrete output voltage: 5...125 V DC; 5...250 V AC

Discrete output current: 2 A

Complementary

Discrete I/O number: 24

Maximum number of I/O expansion module: 7 (local I/O-Architecture); 14 (remote I/O-Architecture)

Supply voltage limits: 85…264 V

Network frequency: 50/60 Hz

Inrush current: 40 A

Maximum power consumption in VA: 58 VA at 100...240 V with max number of I/O expansion module; 35 VA at 100...240 V without I/O expansion module

Power supply output current: 0.52 A 5 V for expansion bus; 0.16 A 24 V for expansion bus

Discrete input logic: Sink or source (positive/negative)

Discrete input voltage: 24 V

discrete input voltage type: DC

analogue input resolution: 10 bits

LSB value: 10 mV

Conversion time: 1 ms per channel + 1 controller cycle time for analogue input analog input

Permitted overload on inputs: +/- 30 V DC for 5 min (maximum) for analog input; +/- 13 V DC (permanent) for analog input

Voltage state 1 guaranteed: >= 15 V for input

Voltage state 0 guaranteed: <= 5 V for input

Discrete input current: 7 mA for discrete input; 5 mA for fast input

Input impedance: 3.4 kOhm for discrete input; 100 kOhm for analog input; 4.9 kOhm for fast input

Response time: 35 µs turn-off, I2...I5 terminal(s) for input; 10 ms turn-on for output; 10 ms turn-off for output; 5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input; 35 µs turn-on, other terminals terminal(s) for input; 5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input; 100 µs turn-off, other terminals terminal(s) for input

Configurable filtering time: 0 ms for input; 3 ms for input; 12 ms for input

Output voltage limits: 125 V DC; 277 V AC

Maximum current per output common: 4 A at COM 2; 7 A at COM 0; 7 A at COM 1

Absolute accuracy error: +/- 1 % of full scale for analog input

Electrical durability: 100000 cycles AC-12, 120 V, 240 VA, resistive; 100000 cycles AC-12, 240 V, 480 VA, resistive; 300000 cycles AC-12, 120 V, 80 VA, resistive; 300000 cycles AC-12, 240 V, 160 VA, resistive; 100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive; 100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive; 300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive; 300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive; 100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive; 100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive; 300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive; 300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive; 100000 cycles DC-12, 24 V, 48 W, resistive; 300000 cycles DC-12, 24 V, 16 W, resistive; 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms); 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)

Switching frequency: 20 switching operations/minute with maximum load

Mechanical durability: 20000000 cycles for relay output

Minimum load: 1 mA at 5 V DC for relay output

Protection type: Without protection at 5 A

Reset time: 1 s

Memory capacity: 256 kB for user application and data RAM with 10000 instructions; 256 kB for internal variables RAM

Data backed up: 256 kB built-in flash memory for backup of application and data

Data storage equipment: 2 GB SD card (optional)

Battery type: BR2032 or CR2032X lithium non-rechargeable

Backup time: 1 year at 25 °C (by interruption of power supply)

Execution time for 1 KInstruction: 0.3 ms for event and periodic task

Execution time per instruction: 0.2 µs Boolean

Exct time for event task: 60 µs response time

Maximum size of object areas: 255 %TM timers; 512 %M memory bits; 8000 %MW memory words; 255 %C counters; 512 %KW constant words

Realtime clock: With

Clock drift: <= 30 s/month at 25 °C

Regulation loop: Adjustable PID regulator up to 14 simultaneous loops

Counting input number: 4 fast input (HSC mode) at 100 kHz 32 bits

control signal type: A/B; Single phase; Pulse/direction

Integrated connection type: USB port with mini B USB 2.0 connector; Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface ; Ethernet with RJ45 connector

Supply: (serial)serial link supply: 5 V, <200 mA

Transmission rate: 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485; 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232; 480 Mbit/s for USB

Communication port protocol: USB port: USB - SoMachine-Network; Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network; Ethernet

Port Ethernet: 10BASE-T/100BASE-TX 1 port with 100 m copper cable

Communication service: Modbus TCP server; Modbus TCP slave device; DHCP client; Modbus TCP client; Ethernet/IP adapter

Local signalling: 1 LED (green) for PWR; 1 LED (green) for RUN; 1 LED (red) for module error (ERR); 1 LED (green) for SD card access (SD); 1 LED (red) for BAT; 1 LED per channel (green) for I/O state; 1 LED (green) for SL; Ethernet network activity (green) for ACT; Ethernet network link (yellow) for Link (Link Status)

Electrical connection: removable screw terminal block for inputs; removable screw terminal block for outputs; terminal block, 3 terminal(s) for connecting the 24 V DC power supply; connector, 4 terminal(s) for analogue inputs; Mini B USB 2.0 connector for a programming terminal

Maximum cable distance between devices: Shielded cable: <10 m for fast input; Unshielded cable: <30 m for output; Unshielded cable: <30 m for digital input; Unshielded cable: <1 m for analog input

Insulation: Between input and internal logic at 500 V AC; Non-insulated between analogue input and internal logic; Non-insulated between analogue inputs; Between supply and ground at 1500 V AC; Between sensor power supply and ground at 500 V AC; Between input and ground at 500 V AC; Between output and ground at 1500 V AC; Between supply and internal logic at 2300 V AC; Between sensor power supply and internal logic at 500 V AC; Between output and internal logic at 2300 V AC; Between Ethernet terminal and internal logic at 500 V AC; Between supply and sensor power supply at 2300 V AC

Marking: CE

Sensor power supply: 24 V DC at 250 mA supplied by the controller

Mounting support: Top hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit

height: 90 mm

Depth: 70 mm

Width: 110 mm

Net weight: 0.395 kg

Environment

Standards: IEC 61131-2; UL 508; CAN/CSA C22.2 No. 213; IACS E10; ANSI/ISA 12-12-01

product certifications: LR; cULus; ABS; DNV-GL; EAC; RCM; CE; UKCA; cULus HazLoc

Environmental characteristic: Ordinary and hazardous location

Resistance to electrostatic discharge: 8 kV in air conforming to IEC 61000-4-2; 4 kV on contact conforming to IEC 61000-4-2

Resistance to electromagnetic fields: 10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3; 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3; 1 V/m 2...2.7 GHz conforming to IEC 61000-4-3

Resistance to magnetic fields: 30 A/m 50/60 Hz conforming to IEC 61000-4-8

Resistance to fast transients: 2 kV (power lines) conforming to IEC 61000-4-4; 2 kV (relay output) conforming to IEC 61000-4-4; 1 kV (I/O) conforming to IEC 61000-4-4; 1 kV (Ethernet line) conforming to IEC 61000-4-4; 1 kV (serial link) conforming to IEC 61000-4-4

Surge withstand: 2 kV power lines (AC) common mode conforming to IEC 61000-4-5; 2 kV relay output common mode conforming to IEC 61000-4-5; 1 kV I/O common mode conforming to IEC 61000-4-5; 1 kV shielded cable common mode conforming to IEC 61000-4-5; 0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5; 1 kV power lines (AC) differential mode conforming to IEC 61000-4-5; 1 kV relay output differential mode conforming to IEC 61000-4-5; 0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5

Resistance to conducted disturbances: 10 V 0.15...80 MHz conforming to IEC 61000-4-6; 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL); 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)

Electromagnetic emission: Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011; Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011; Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011; Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011; Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011; Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011; Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011

Immunity to microbreaks: 10 ms

Ambient air temperature for operation: -10…55 °C (horizontal installation); -10…35 °C (vertical installation)

Ambient air temperature for storage: -25…70 °C

Relative humidity: 10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage)

IP degree of protection: IP20 with protective cover in place

Pollution degree: <= 2

Operating altitude: 0...2000 m

Storage altitude: 0…3000 m

Vibration resistance: 3.5 mm at 5…8.4 Hz on symmetrical rail; 3.5 mm at 5…8.4 Hz on panel mounting; 1 gn at 8.4…150 Hz on symmetrical rail; 1 gn at 8.4…150 Hz on panel mounting

Shock resistance: 98 m/s² for 11 ms

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 11.156 cm

Package 1 Width: 14.152 cm

Package 1 Length: 15.681 cm

Package 1 Weight: 650.0 g

Unit Type of Package 2: CAR

Number of Units in Package 2: 20

Package 2 Height: 29.9 cm

Package 2 Width: 39.4 cm

Package 2 Length: 57.5 cm

Package 2 Weight: 14.171 kg

Unit Type of Package 3: P12

Number of Units in Package 3: 240

Package 3 Height: 105.0 cm

Package 3 Width: 120.0 cm

Package 3 Length: 80.0 cm

Package 3 Weight: 182 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1403012EN

Circularity Profile: ENVEOLI1403012EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free: Yes

© 2018 Alplan Kft.