Schneider-Electric
LV429184
Tariff code: 8536303099
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: LV429184 - trip unit Micrologic 6.2 E-M for Compact NSX 100/160/250 circuit breakers, electronic, rating 25 A, 3 poles 3d
Main
Range: ComPact
Range of product: ComPact NSX100...250
Product name: Micrologic
Product or component type: Trip unit
Trip unit name: Micrologic 6.2 E-M
Trip unit technology: Electronic
Range compatibility: ComPact NSX100; ComPact NSX160; ComPact NSX250
Device application: Motor
Poles description: 3P
Protected poles description: 3t
Trip unit protection functions: LSIG
Protection type: L : for overload protection (long time); S : for short time short-circuit protection; I : for instantaneous short-circuit protection; G : for ground fault protection
[In] rated current: 25 A at 65 °C
[Ue] rated operational voltage: 690 V AC 50/60 Hz
Network type: AC
Network frequency: 50/60 Hz
Complementary
Motor tripping class: 20; 30; 10; 5
Complementary motor protection: Current unbalance; Stalled rotor; Underload; Protracted starting time
Long time pick-up adjustment type Ir: Adjustable 9 settings
long time pick-up adjustment range: 12...25 A
long time delay adjustment type: Adjustable
[tr] long-time delay adjustment range: 120 s at 1.5 x Ir for trip class 5; 6.5 s at 6 x Ir for trip class 5; 5 s at 7.2 x Ir for trip class 5; 240 s at 1.5 x Ir for trip class 10; 13.5 s at 6 x Ir for trip class 10; 10 s at 7.2 x Ir for trip class 10; 480 s at 1.5 x Ir for trip class 20; 26 s at 6 x Ir for trip class 20; 20 s at 7.2 x Ir for trip class 20; 720 s at 1.5 x Ir for trip class 30; 38 s at 6 x Ir for trip class 30; 30 s at 7.2 x Ir for trip class 30
Thermal memory: 20 minutes before and after tripping
Short-time pick-up adjustment type Isd: Adjustable 9 settings
[Isd] short-time pick-up adjustment range: 5...13 x Ir
Short-time delay adjustment type: Fixed
[tsd] short-time delay adjustment range: 0.01 s
Instantaneous pick-up adjustment type Ii: Fixed
Instantaneous pick-up adjustment range: 425 A
Ground-fault pick-up adjustment type: Adjustable
[Ig] ground-fault pick-up adjustment range: 0.2...1 x In for In > 50 A; 0.3...1 x In for In = 50 A; 0.6...1 x In for In = 25 A; Ig enable on/off
Ground-fault time delay adjustment type -tg: Adjustable
[tg] Ground-fault time delay adjustment range: 0…0.4 s
Earth-leakage protection: Without
Zone selective interlocking ZSI: With
Local signalling: Flashing LED (green) for ready to operate; LED 95 % Ith (red) for temperature over set point
Display type: LCD display
type of measurement: Energy meter
Electrical data recording: Maintenance indicators
Environment
Standards: EN/IEC 60947-2; UL 508
Product certifications: Marine; EAC; CCC
Ambient air temperature for operation: -25…70 °C
Ambient air temperature for storage: -40…85 °C
Packing Units
Unit Type of Package 1: Db
Number of Units in Package 1: 1
Package 1 Height: 9.5 cm
Package 1 Width: 15.0 cm
Package 1 Length: 11.0 cm
Package 1 Weight: 550.0 g
Unit Type of Package 2: Doboz
Number of Units in Package 2: 11
Package 2 Height: 30.0 cm
Package 2 Width: 30.0 cm
Package 2 Length: 40.0 cm
Package 2 Weight: 6.537 kg
Offer Sustainability
Sustainable offer status: Green Premium product
EU RoHS Directive: Compliant
Mercury free: Yes
China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP120606EN
Circularity Profile: ENVEOLI120604EN