Skip to main content

Schneider-Electric
LC3D80B7

TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil
Net discounted price 892.53 EUR
Available when ordered (delivery time: 20 working day(s))
Barcode: 3389110094206
Tariff code: 8536419089

Link to the manufacturers site: LC3D80B7 - TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Main

Range of produc: TeSys Deca

Range: TeSys

Product name: TeSys Deca

Product or component type: Star delta starter

Device short name: LC3D

contactor application: Motor control

utilisation category: AC-3

device presentation: Pre-wired

Poles description: 3 x 3P

Pole contact composition: 3 x 3 NO

[Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz

[Ie] rated operational current: 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

Motor power kW: 37 kW at 220/230 V AC 50/60 Hz; 75 kW at 380/400 V AC 50/60 Hz; 75 kW at 415 V AC 50/60 Hz; 75 kW at 440 V AC 50/60 Hz

Control circuit type: AC at 50/60 Hz

[Uc] control circuit voltage: 24 V AC 50/60 Hz

Auxiliary contact composition: 1 NC for KM2 line contactor; 1 NO for KM3 delta contactor

[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947

Overvoltage category: III

[Ui] rated insulation voltage: Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1; Signalling circuit: 1000 V conforming to IEC 60947-1

Electrical durability: 10 Mcycles 80 A AC-3 at Ue <= 440 V

mounting support: Plate

Standards: EN 60947-4-1; CSA C22.2 No 14; EN 60947-5-1; IEC 60947-4-1; UL 508; IEC 60947-5-1

product certifications: GL; CCC; UL; GOST; LROS (Lloyds register of shipping); CSA; DNV; RINA; BV

Complementary

Connections - terminals: Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 4…25 mm² - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 4…16 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 4…25 mm² - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end

Tightening torque: Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 12 N.m - on screw clamp terminals - with screwdriver flat Ø 6...8 mm

Mechanical durability: 4 Mcycles

Maximum operating rate: 30 cyc/h 60 °C

Starting time: 30 s

Coil technology: Without built-in suppressor module

Control circuit voltage limits: Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C); Operational: 0.8...1.1 Uc at 50 Hz (at <55 °C); Operational: 0.85...1.1 Uc at 60 Hz (at <55 °C)

Inrush power in VA: 140 VA 60 Hz cos phi 0.75 (at 20 °C); 160 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA: 13 VA 60 Hz cos phi 0.3 (at 20 °C); 15 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation: 4…5 W at 50/60 Hz

Auxiliary contacts type: Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC; Mirror contact conforming to IEC 60947-4-1 3 x 1 NC

Signalling circuit frequency: 25...400 Hz

Minimum switching current: 5 mA for signalling circuit

Switching voltage: 17 V for signalling circuit

Non-overlap time: 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact

Width: 311 mm

height: 143 mm

Depth: 183 mm

Net weight: 5.2 kg

Power range: 30…50 kW at 200…240 V 3 phases; 55…100 kW at 380…440 V 3 phases; 15…25 kW at 200…240 V 3 phases; 30…50 kW at 380…440 V 3 phases

Motor starter type: Star delta starter

Contactor coil voltage: 24 V AC standard

Environment

Insulation resistance: > 10 MOhm for signalling circuit

IP degree of protection: IP20 front face conforming to IEC 60529

Protective treatment: TH conforming to IEC 60068-2-30

Pollution degree: 3

Ambient air temperature for storage: -60…80 °C

Ambient air temperature for operation: -40…60 °C; 60…70 °C with derating

Operating altitude: 3000 m

Fire resistance: 850 °C conforming to IEC 60695-2-1

Flame retardance: V1 conforming to UL 94

Mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 Hz; Shocks contactor open: 8 Gn for 11 ms; Vibrations contactor closed: 3 Gn, 5...300 Hz; Shocks contactor closed: 10 Gn for 11 ms

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 27.0 cm

Package 1 Width: 26.0 cm

Package 1 Length: 38.0 cm

Package 1 Weight: 6.455 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Compliant

Toxic heavy metal free: Yes

Mercury free: Yes

China RoHS Regulation:  Pro-active China RoHS declaration (out of China RoHS legal scope)

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP110205EN

Circularity Profile: N/A

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free: Yes

© 2018 Alplan Kft.