Schneider-Electric
LC1K1210M7
Tariff code: 8536490099
Link to the manufacturers site: LC1K1210M7 - TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NO aux. - 220...230 V AC coil
Main
Range of product: TeSys K
Range: TeSys
Product or component type: Contactor
Device short name: LC1K
device application: Control
Contactor application: Motor control; Resistive load
Complementary
Utilisation category: AC-3; AC-3e; AC-1; AC-4
Poles description: 3P
Pole contact composition: 3 NO
[Ue] rated operational voltage: Power circuit: <= 690 V AC <= 400 Hz; Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current: 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit; 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Control circuit type: AC at 50/60 Hz
[Uc] control circuit voltage: 220...230 V AC 50/60 Hz
Motor power kW: 3 kW at 220...230 V AC 50/60 Hz AC-3; 5.5 kW at 380...415 V AC 50/60 Hz AC-3; 5.5 kW at 440 V AC 50/60 Hz AC-3; 4 kW at 690 V AC 50/60 Hz AC-3; 3 kW at 220...230 V AC 50/60 Hz AC-3e; 5.5 kW at 380...415 V AC 50/60 Hz AC-3e; 5.5 kW at 440 V AC 50/60 Hz AC-3e; 4 kW at 690 V AC 50/60 Hz AC-3e; 3 kW at 220...230 V AC 50/60 Hz AC-4; 5.5 kW at 380...415 V AC 50/60 Hz AC-4; 5.5 kW at 440 V AC 50/60 Hz AC-4; 4 kW at 690 V AC 50/60 Hz AC-4
Auxiliary contact composition: 1 NO
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit
Irms rated making capacity: 144 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity: 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current: 115 A 50 °C - 1 s for power circuit; 105 A 50 °C - 5 s for power circuit; 100 A 50 °C - 10 s for power circuit; 75 A 50 °C - 30 s for power circuit; 55 A 50 °C - 1 min for power circuit; 50 A 50 °C - 3 min for power circuit; 25 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit
Associated fuse rating: 25 A gG at <= 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660
Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage: Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance: > 10 MOhm for signalling circuit
Inrush power in VA: 30 VA (at 20 °C)
Hold-in power consumption in VA: 4.5 VA (at 20 °C)
Heat dissipation: 1.3 W
Control circuit voltage limits: Operational: 0.8...1.15 Uc (at <50 °C); Drop-out: >= 0.20 Uc (at <50 °C)
Connections - terminals: Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate: 3600 cyc/h
Auxiliary contacts type: type instantaneous 1 NO
Signalling circuit frequency: <= 400 Hz
Minimum switching current: 5 mA for signalling circuit
Minimum switching voltage: 17 V for signalling circuit
Mounting support: Rail; Plate
Tightening torque: 0.8…1.3 N.m - on screw clamp terminals Philips No 2; 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm; 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Operating time: 10...20 ms coil de-energisation and NO opening; 10...20 ms coil energisation and NO closing
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance: 0.5 mm
Mechanical durability: 10 Mcycles
Electrical durability: 1.3 Mcycles 12 A AC-3 at Ue <= 440 V; 1.3 Mcycles 12 A AC-3e at Ue <= 440 V; 0.3 Mcycles 20 A AC-1 at Ue <= 690 V; 0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Mechanical robustness: Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Height: 58 mm
Width: 45 mm
Depth: 57 mm
Net weight: 0.18 kg
Compatibility code: LC1K
Environment
Standards: EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certifications: CB Scheme; CCC; UL; CSA; EAC; CE; UKCA
IP degree of protection: IP2X conforming to VDE 0106
Protective treatment: TC conforming to IEC 60068; TC conforming to DIN 50016
Ambient air temperature for storage: -50…80 °C
Operating altitude: 2000 m without derating
Flame retardance: V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 6.600 cm
Package 1 Width: 6.200 cm
Package 1 Length: 4.800 cm
Package 1 Weight: 177.000 g
Unit Type of Package 2: S02
Number of Units in Package 2: 50
Package 2 Height: 15.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 9.200 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Compliant
Toxic heavy metal free: Yes
Mercury free: Yes
China RoHS Regulation: Pro-active China RoHS declaration (out of China RoHS legal scope)
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP1503003
Circularity Profile: ENVEOLI1503003
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.