Schneider-Electric
ATV980C16Q4X1
Tariff code: 8504409590
Link to the manufacturers site: ATV980C16Q4X1 - Regenerative Drive System ATV980 -160/132 kW - 400V with CE - IP23
Main
Device application: Industrial application
Device short name: ATV980
Provided equipment: Enclosure Spacial SF; Graphical operating panel in the enclosure door; Frequency inverter; Main switch; Line choke; Terminal block main supply; Terminal block motor
Colour of enclosure: Light grey (RAL 7035)
Noise level: 70 dB conforming to 86/188/EEC - physical agents (noise) directive
Type of polarization: No impedance for Modbus serial
Supply: External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection; Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 0.5, <10 mA, protection type: overload and short-circuit protection
Range of produc: Altivar Process ATV900
Product or component type: Variable speed drive
communication port protocol: Modbus serial; EtherNet/IP; Modbus TCP
[Us] rated supply voltage: 380...415 V - 10...6 %
Motor power kW: 160 kW for normal duty; 132 kW for heavy duty
Complementary
Product destination: asynchronous motors; synchronous motors
Type of cooling: Forced convection
Supply frequency: 50...60 Hz +/- 5 %
Network number of phases: 3 phases
Output voltage: <= power supply voltage
Permissible temporary current boost: 1.2 x In during 60 s (normal duty); 1.5 x In during 60 s (heavy duty)
Speed drive output frequency: 0.1…599 Hz
Continuous output current: 302 A at 2.5 kHz for normal duty; 250 A at 2.5 kHz for heavy duty
Energy efficiency ratio: 0.965
Power dissipation in W: 6400 W, total (normal duty); 5100 W, total (heavy duty); 820 W, control part (normal duty); 650 W, control part (heavy duty)
Volume of cooling air: 1160 m3/h for power; 140 m3/h for control
Prospective line Isc: 50 kA for 100 ms
Motor recommanded cable cross section: 1 x (3 x 185 mm²) (normal duty); 2 x (3 x 95 mm²) (normal duty); 1 x (3 x 150 mm²) (heavy duty); 2 x (3 x 70 mm²) (heavy duty)
Height: 2150 mm
Depth: 664 mm
Option card: Slot A: communication module for EtherCAT; Slot A/slot B/slot C: digital and analog I/O extension module; Slot A/slot B/slot C: output relay extension module; Slot A: communication module for CANopen daisy chain RJ45; Slot A: communication module for CANopen screw terminals; Slot A: communication module for CANopen SUB-D 9; Slot A: communication module for DeviceNet; Slot A: communication module for Profibus DP V1; Slot A: communication module for PROFINET; Slot B: digital encoder interface module; Slot B: 512 V digital encoder interface module; Slot B: resolver encoder interface module; Slot B: analog encoder interface module
Safety function: STO (safe torque off), level SIL 3 for <= 100 ms
Protection type: Motor: thermal protection; Motor: safe torque off; Motor: motor phase break; Drive: thermal protection; Drive: safe torque off; Drive: overheating; Drive: overcurrent (between output phases and earth); Drive: overload (output); Drive: short-circuit protection; Drive: motor phase break; Drive: overvoltage (DC bus); Drive: line supply overvoltage; Drive: line supply undervoltage; Drive: line supply phase loss; Drive: overspeed; Drive: break on the control circuit; Drive: short-circuit protection with semi-conductor fuse (main supply); Drive: fan monitoring
Frequency resolution: Display unit: 0.1 Hz; Analog input: 0.012/50 Hz
Connector type: 2 RJ45 for Ethernet IP/Modbus TCP on the control block; 1 RJ45 for Modbus serial on the control block
Physical interface: 2-wire RS 485 for Modbus serial
Transmission frame: RTU for Modbus serial
Transmission rate: 10/100 Mbit/s for Ethernet IP/Modbus TCP; 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
Exchange mode: Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format: 8 bits, configurable odd, even or no parity for Modbus serial
Number of addresses: 1…247 for Modbus serial
Local signalling: LCD display unit front door operation function, status and configuration
Input compatibility: DI1...DI8: discrete input level 1 PLC conforming to EN/IEC 61131-2; DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logic: Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1); Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1); Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
Sampling duration: 2 ms +/- 0.5 ms (DI1...DI8) - discrete input; 5 ms +/- 1 ms (DI7, DI8) - pulse input; 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input; 5 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy: +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error: AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output
Refresh time: Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Isolation: Between power and control terminals
Insulation resistance: > 1 MOhm 500 V DC for 1 minute to earth
Discrete input number: 10
Discrete input type: DI1...DI8 programmable, 24 V DC (30 V), impedance: 3.5 kOhm; DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC; STOA, STOB safe torque off, 24 V DC, impedance: > 2.2 kOhm
Discrete input logic: 16 preset speeds
Discrete output number: 2
Discrete output type: Logic output DQ+ 0…1 kHz <= 30 V DC 100.0 mA; Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20.0 mA; Logic output DQ- 0…1 kHz <= 30 V DC 100.0 mA
analogue input number: 3
Analogue input type: AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
analogue output number: 2
Analogue output type: Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits
Relay output number: 3
Relay output type: Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles; Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles
Maximum switching current: Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC; Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 250 V AC; Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 30 V DC; Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Minimum switching current: Relay output R1, R2, R3: 5 mA at 24 V DC
Method of access: Slave Modbus TCP
Asynchronous motor control profile: Optimized torque mode; Variable torque standard; Constant torque standard
Synchronous motor control profile: Permanent magnet motor
Acceleration and deceleration ramps: S, U or customized; Linear adjustable separately from 0.01 to 9000 s
Motor slip compensation: Adjustable; Not available in permanent magnet motor law; Can be suppressed; Automatic whatever the load
Switching frequency: 2...8 kHz adjustable with derating factor
Nominal switching frequency: 2.5 kHz
Braking to standstill: By DC injection
Line current: 252 A at 400 V (normal duty); 208 A at 400 V (heavy duty)
Apparent power: 174 kVA at 400 V (normal duty); 144 kVA at 400 V (heavy duty)
Maximum transient current: 362 A during 60 s per 10 min (normal duty); 375 A during 60 s per 10 min (heavy duty)
Short-circuit protection: Upstream: 300 A gG fuse (heavy duty); Upstream: 315 A gG fuse (normal duty); Internal: 350 A aR fuse
Electrical connection: Removable screw terminals, clamping capacity: 0.5...1.5 mm² for control; M12 bar for main supply; M12 bar for motor
Cable entry: Bottom
Width: 600 mm
Net weight: 400 kg
Environment
IP degree of protection: IP23 conforming to IEC 61800-5-1
EMC filter: Integrated conforming to EN/IEC 61800-3, category C3, shielded cable with 50 m; Integrated conforming to EN/IEC 61800-3, category C4, unshielded cable with 80 m
Pollution degree: 2 conforming to EN/IEC 61800-5-1
Vibration resistance: 1.5 mm peak to peak (f= 3…20 Hz) conforming to IEC 60068-2-6; 0.6 gn (f= 10…200 Hz) conforming to IEC 60068-2-6; 3M3 conforming to IEC 60721-3-3; 1.5 mm peak to peak (f= 3…10 Hz) conforming to IEC 60068-2-6
Shock resistance: 4 gn for 11 ms conforming to IEC 60068-2-27; 3M2 conforming to IEC 60721-3-3
Relative humidity: 5…95 % without condensation conforming to IEC 60068-2-3
Operating altitude: <= 1000 m without derating; 1000...2000 m with current derating 1 % per 100 m; 2000...3800 m with current derating 1 % per 100 m for TT earthing system; 2000...3800 m with current derating 1 % per 100 m for TN earthing system; 2000...3800 m with current derating 1 % per 100 m for IT earthing system; 3800...4800 m with current derating 1 % per 100 m for TT earthing system; 3800...4800 m with current derating 1 % per 100 m for TN earthing system
Environmental characteristic: Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3; Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3; Humidity resistant class 3K3 conforming to EN/IEC 60721-3-3
Product certifications: ATEX; C-Tick; EAC
Operating position: Vertical +/- 10 degree
Marking: CE
Standards: EN/IEC 60204-1; EN/IEC 61800-2; EN/IEC 61800-3; EN/IEC 61800-5-1
Maximum THDI: <5 % full load conforming to IEEE 519
Assembly style: In floor-standing enclosure compact version
Electromagnetic compatibility: Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Overvoltage category: III
Ambient air temperature for operation: -10…0 °C without derating (with option enclosure heating); 0…40 °C without derating; 40…50 °C with derating factor
Ambient air temperature for storage: -25…70 °C
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 215 cm
Package 1 Width: 66.9 cm
Package 1 Length: 60 cm
Package 1 Weight: 445 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP1512007EN
Circularity Profile: ENVEOLI1512007EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Take-back: Take-back program available