Skip to main content

Schneider-Electric
ATV660C25Q4X1

Altivar Process ATV660 frekvenciaváltó, THDI<44%, 250kW, 3f, 400VAC, IP23, szekrényes, vonali- és motorfojtóval
Barcode: 3606480749018
Tariff code: 8504409590

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: ATV660C25Q4X1 - Altivar Process ATV660 frekvenciaváltó, THDI<44%, 250kW, 3f, 400VAC, IP23, szekrényes, vonali- és motorfojtóval

Main

Range of produc: Altivar Process ATV600

Product or component type: Variable speed drive

Product specific application: Process and utilities

Device short name: ATV660

Product destination: Synchronous motors; Asynchronous motors

Assembly style: In floor-standing enclosure compact version

Provided equipment: Enclosure Spacial SF; Graphical operating panel in the enclosure door; Frequency inverter; Main switch; Line choke; Terminal block main supply; Terminal block motor

Cable entry: Bottom

Colour of enclosure: Light grey (RAL 7035)

IP degree of protection: IP23 conforming to IEC 61800-5-1

Type of cooling: Forced convection

[Us] rated supply voltage: 380...415 V - 10...6 %

Supply frequency: 50/60 Hz +/-5 %

Network number of phases: 3 phases

Overvoltage category: III

Asynchronous motor control profile: Variable torque standard; Constant torque standard; Optimized torque mode

Synchronous motor control profile: Permanent magnet motor

Output voltage: <= power supply voltage

Permissible temporary current boost: 1.1 x In during 60 s (normal duty); 1.5 x In during 60 s (heavy duty)

Nominal switching frequency: 2.5 kHz

Switching frequency: 2...8 kHz adjustable with derating factor

Speed drive output frequency: 0.1…500 Hz

Motor power kW: 250 kW for normal duty; 200 kW for heavy duty

Continuous output current: 477 A at 2.5 kHz for normal duty; 370 A at 2.5 kHz for heavy duty

Maximum transient current: 525 A during 60 s per 10 min (normal duty); 555 A during 60 s per 10 min (heavy duty)

Line current: 432 A at 400 V (normal duty); 353 A at 400 V (heavy duty)

Apparent power: 299 kVA at 400 V (normal duty); 244 kVA at 400 V (heavy duty)

Maximum THDI: <47 % full load conforming to IEC 61000-3-12

Short-circuit protection: Internal: 315.0 A 2 aR fuse; Upstream: 500.0 A gG fuse (normal duty); Upstream: 400.0 A gG fuse (heavy duty)

Energy efficiency ratio: 0.98

Power dissipation in W: 5750 W, total (normal duty); 4340 W, total (heavy duty); 730 W, control part (normal duty); 520 W, control part (heavy duty)

Volume of cooling air: 140 m3/h for control; 1160 m3/h for power

Noise level: 70 dB conforming to 86/188/EEC - physical agents (noise) directive

Prospective line Isc: 50 kA for 100 ms

Electrical connection: Removable screw terminals, clamping capacity: 0.5...1.5 mm² for control; M12 bar for main supply; M12 bar for motor

Motor recommanded cable cross section: 2 x (3 x 150 mm²) (normal duty); 3 x (3 x 95 mm²) (normal duty); 2 x (3 x 120 mm²) (heavy duty); 3 x (3 x 70 mm²) (heavy duty)

Width: 600 mm

Height: 2150 mm

Depth: 664 mm

Net weight: 400 kg

Discrete input logic: 16 preset speeds

communication port protocol: Modbus TCP; Modbus serial; EtherNet/IP

Option card: Slot A: communication module, Profibus DP V1; Slot A: communication module, PROFINET; Slot A: communication module, DeviceNet; Slot A: communication module, Modbus TCP/EtherNet/IP; Slot A: communication module, CANopen daisy chain RJ45; Slot A: communication module, CANopen SUB-D 9; Slot A: communication module, CANopen screw terminals; Slot A/slot B: digital and analog I/O extension module; Slot A/slot B: output relay extension module

Safety function: STO (safe torque off), level SIL 3 for <= 100 ms

EMC filter: Integrated conforming to EN/IEC 61800-3, category C3, shielded cable with 50 m; Integrated conforming to EN/IEC 61800-3, category C4, unshielded cable with 80 m

Complementary

Motor slip compensation: Not available in permanent magnet motor law; Can be suppressed; Automatic whatever the load; Adjustable

Acceleration and deceleration ramps: S, U or customized; Linear adjustable separately from 0.01 to 9000 s

Braking to standstill: By DC injection

Protection type: Motor: thermal protection; Motor: safe torque off; Motor: motor phase break; Drive: thermal protection; Drive: safe torque off; Drive: overheating; Drive: overcurrent (between output phases and earth); Drive: overload (output); Drive: short-circuit protection; Drive: motor phase break; Drive: overvoltage (DC bus); Drive: line supply overvoltage; Drive: line supply undervoltage; Drive: line supply phase loss; Drive: overspeed; Drive: break on the control circuit; Drive: short-circuit protection with semi-conductor fuse (main supply); Drive: fan monitoring

Frequency resolution: Display unit: 0.1 Hz; Analog input: 0.012/50 Hz

Connector type: RJ45 (on the control block) for Modbus serial; RJ45 (on the control block) for Ethernet IP/Modbus TCP

Physical interface: 2-wire RS 485 for Modbus serial

Transmission frame: RTU for Modbus serial

Transmission rate: 10/100 Mbit/s for Ethernet IP/Modbus TCP; 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial

Exchange mode: Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP

Data format: 8 bits, configurable odd, even or no parity for Modbus serial

Type of polarization: No impedance for Modbus serial

Number of addresses: 1…247 for Modbus serial

Method of access: Slave Modbus TCP

Supply: External supply for digital inputs: 24 V DC (10…30 V), <1.25 mA, protection type: overload and short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection; Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection

Local signalling: LCD display unit front door operation function, status and configuration

analogue input number: 3

Analogue input type: AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits

Discrete input number: 8

Discrete input type: DI1...DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm; DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V); STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm

Input compatibility: DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2; DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2

Discrete input logic: Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1); Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1); Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)

analogue output number: 2

Analogue output type: Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits

Sampling duration: 2 ms +/- 0.5 ms (DI1...DI4) - discrete input; 5 ms +/- 1 ms (DI5, DI6) - discrete input; 5 ms +/- 1 ms (AI1, AI2, AI3) - analog input; 10 ms +/- 1 ms (AQ1, AQ2) - analog output

Accuracy: +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output

Linearity error: AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output

Relay output number: 3

Relay output type: Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles; Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles

Refresh time: Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)

Minimum switching current: Relay output R1, R2, R3: 5 mA at 24 V DC

Maximum switching current: Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC

Isolation: Between power and control terminals

Environment

Insulation resistance: > 1 MOhm 500 V DC for 1 minute to earth

Operating position: Vertical +/- 10 degree

Electromagnetic compatibility: Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

Pollution degree: 2 conforming to EN/IEC 61800-5-1

Vibration resistance: 1.5 mm peak to peak (f= 3…10 Hz) conforming to IEC 60068-2-6; 0.6 gn (f= 10…200 Hz) conforming to IEC 60068-2-6; 3M3 conforming to IEC 60721-3-3

Shock resistance: 4 gn for 11 ms conforming to IEC 60068-2-27; 3M2 conforming to IEC 60721-3-3

Relative humidity: 5…95 % without condensation conforming to IEC 60068-2-3

Ambient air temperature for operation: -10…0 °C without derating (with option enclosure heating); 0…40 °C without derating; 40…50 °C with derating factor

Ambient air temperature for storage: -25…70 °C

Operating altitude: < 1000 m without derating; 1000...2000 m with current derating 1 % per 100 m; 2000...3800 m with current derating 1 % per 100 m for TT earthing system; 2000...3800 m with current derating 1 % per 100 m for TN earthing system; 2000...3800 m with current derating 1 % per 100 m for IT earthing system; 3800...4800 m with current derating 1 % per 100 m for TT earthing system; 3800...4800 m with current derating 1 % per 100 m for TN earthing system

Environmental characteristic: Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3; Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3; Humidity resistant class 3K3 conforming to EN/IEC 60721-3-3

Standards: EN/IEC 60204-1; EN/IEC 61800-2; EN/IEC 61800-3; EN/IEC 61800-5-1

Product certifications: ATEX; EAC; C-Tick

Marking: CE

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 215 cm

Package 1 Width: 66.9 cm

Package 1 Length: 60 cm

Package 1 Weight: 445 kg

Unit Type of Package 2: CAR

Number of Units in Package 2: 1

Package 2 Height: 230 cm

Package 2 Width: 80 cm

Package 2 Length: 75 cm

Package 2 Weight: 420 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1506003EN

Circularity Profile: ENVEOLI1506003EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Take-back: Take-back program available

© 2018 Alplan Kft.