Skip to main content

Schneider-Electric
ATV630D45Y6

Altivar Process ATV630 frekvenciaváltó, 45kW, 3f, 690VAC, IP21, falra szerelhető
Net discounted price 4,660.86 EUR
Available when ordered (delivery time: 8 working day(s))
Barcode: 3606481325204
Tariff code: 8504409590

Link to the manufacturers site: ATV630D45Y6 - Altivar Process ATV630 frekvenciaváltó, 45kW, 3f, 690VAC, IP21, falra szerelhető

Main

Range of produc: Altivar Process ATV600

Product or component type: Variable speed drive

Product specific application: Process and utilities

Device short name: ATV630

variant: Standard version

Product destination: Asynchronous motors; Synchronous motors

EMC filter: Integrated with 25 m conforming to IEC 61800-3 category C3

IP degree of protection: IP00 conforming to IEC 61800-5-1; IP00 conforming to IEC 60529; IP20 (with kit VW3A9706) conforming to IEC 61800-5-1; IP20 (with kit VW3A9706) conforming to IEC 60529

[Us] rated supply voltage: 500...690 V

Type of cooling: Forced convection

Supply frequency: 50...60 Hz - 5...5 %

[Us] rated supply voltage: 500...690 V - 15...10 %

Motor power kW: 37 kW at 500 V (normal duty); 30 kW at 500 V (heavy duty); 45 kW at 690 V (normal duty); 37 kW at 690 V (heavy duty)

Motor power hp: 50 hp at 500 V normal duty; 40 hp at 500 V heavy duty; 60 hp at 690 V normal duty; 50 hp at 690 V heavy duty

Line current: 55.6 A at 500 V (normal duty); 54.4 A at 690 V (normal duty); 47.2 A at 500 V (heavy duty); 46.2 A at 690 V (heavy duty)

Prospective line Isc: 70 kA

Apparent power: 65 kVA at 690 V (normal duty); 55.2 kVA at 690 V (heavy duty)

Continuous output current: 55 A at 2.5 kHz for normal duty; 45 A at 2.5 kHz for heavy duty

Asynchronous motor control profile: Optimized torque mode; Constant torque standard; Variable torque standard

Synchronous motor control profile: Permanent magnet motor; Synchronous reluctance motor

Speed drive output frequency: 0.1…500 Hz

Nominal switching frequency: 2.5 kHz

Switching frequency: 1...4.9 kHz adjustable; 2.5...4.9 kHz with derating factor

Safety function: STO (safe torque off) SIL 3

Discrete input logic: 16 preset speeds

communication port protocol: Modbus serial; Ethernet; Modbus TCP

Option card: Slot A: communication module, Profibus DP V1; Slot A: communication module, PROFINET; Slot A: communication module, DeviceNet; Slot A: communication module, Modbus TCP/EtherNet/IP; Slot A: communication module, CANopen daisy chain RJ45; Slot A: communication module, CANopen SUB-D 9; Slot A: communication module, CANopen screw terminals; Slot A/slot B: digital and analog I/O extension module; Slot A/slot B: output relay extension module; Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link; Communication module, BACnet MS/TP; Communication module, Ethernet Powerlink

Complementary

Design of frequency changer: U converter

Network frequency: 50...60 Hz

Ambient air transport temperature: -40…70 °C

Relative symmetric mains voltage tolerance: 10 %

Maximum output voltage: 690.0 V

Relative symmetric network frequency tolerance: 5 %

Maximum acceleration under shock impact (during operation): 150 m/s² at 11 ms

Permitted relative humidity (during operation): Class 3K5 according to EN 60721-3

Maximum acceleration under vibrational stress (during operation): 10 m/s² at 13...200 Hz

Nominal output power: 45.0 kW

4 quadrant operation possible: False

Permitted relative humidity (during transport): Class 2K5 according to EN 60721-3

Permitted relative humidity (during storage): Class 1K5 according to EN 60721-3

Capacity of DC link: 2500.0 µF

Maximum deflection under vibratory load (during operation): 1.5 mm at 2...13 Hz

Operating element present: True

Number of HW interfaces serial TTY: 0

Power loss per device current dependent: 842.0 W

Power loss static current independent: 58.0 W

Number of output phases: 3

Maximum acceleration under vibratory load (during transport): 10 m/s² at 13...200 Hz

Number of input phases: 3

Number of inputs, potential-free: 0

Maximum deflection under vibratory load (during transport): 1.5 mm at 2...13 Hz

Brake chopper integrated: False

Maximum acceleration under shock load (during transport): 150 m/s² at 11 ms

Number of HW interfaces USB: 0

Number of HW interfaces other: 0

Optical interface present: False

Computer port: True

Supporting protocol for TCP/IP: True

Application in industrial area permitted: True

Application in domestic and commercial area permitted: False

Supporting protocol for PROFIBUS: True

Number of HW interfaces industrial Ethernet: 1

Number of inputs, bidirectional, not potential-free: 0

1 phase low current possible: False

Number of HW interfaces parallel: 0

Supporting protocol for KNX: False

Supporting protocol for ASI: False

Number of HW interfaces PROFINET: 0

Supporting protocol for CAN: True

Supporting protocol for INTERBUS: False

Supporting protocol for DeviceNet: False

Supporting protocol for SUCONET: False

Supporting protocol for LON: False

Supporting protocol for MODBUS: True

Supporting protocol for Data-Highway: False

Supporting protocol for PROFINET IO: True

Supporting protocol for PROFINET CBA: True

Maximum acceleration under shock load (during storage): 150 m/s² at 11 ms

Supporting protocol for Foundation Fieldbus: False

Supporting protocol for SERCOS: False

Maximum deflection under vibratory load (during storage): 1.5 mm at 2...13 Hz

Supporting protocol for DeviceNet Safety: False

Supporting protocol for INTERBUS-Safety: False

Supporting protocol for PROFIsafe: False

Supporting protocol for EtherNet/IP: True

Supporting protocol for AS-Interface Safety at Work: False

Maximum acceleration under vibratory load (during storage): 10 m/s² at 13...200 Hz

With safety function Safe torque off (STO): True

With sft fct Safe Stop 2 (SS2): False

With safety function Safe Stop 1 (SS1): False

Supporting protocol for SafetyBUS P: False

Supporting protocol for BACnet: False

Supporting protocol for other bus systems: False

Nominal output current: 55.0 A

With safety function Safe brake management (SBC/SBT): False

With safety function Safe Operating Stop (SOS): False

With safety function Safely Limited Position (SLP): False

With safety function Safely Limited Speed (SLS): False

With safety function Safe Speed Monitor (SSM): False

With safety function Safe Direction (SDI): False

Base load current at high overload: 45.0 A

Base load current at low overload: 55.0 A

Number of HW interfaces serial RS232: 0

With safety function Safe programmable logic: False

With safety function Safe Position (SP): False

EMC limit value (complied): True

Environmental class (during transport): Class 2C3 according to EN 60721-3-2; Class 2S1 according to EN 60721-3-2

Environmental class (during operation): Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3

Environmental class (during storage): Class 1C3 according to EN 60721-3-1; Class 1S2 according to EN 60721-3-1

Number of HW interfaces serial RS422: 0

Number of HW interfaces serial RS485: 1

Mounting mode: Wall mount

Maximum transient current: 60.5 A during 60 s (normal duty); 67.5 A during 60 s (heavy duty)

Network number of phases: 3 phases

Discrete output number: 0

Discrete output type: Relay outputs R1A, R1B, R1C 250 V AC 3000 mA; Relay outputs R1A, R1B, R1C 30 V DC 3000 mA; Relay outputs R2A, R2C 250 V AC 5000 mA; Relay outputs R2A, R2C 30 V DC 5000 mA; Relay outputs R3A, R3C 250 V AC 5000 mA; Relay outputs R3A, R3C 30 V DC 5000 mA

Output voltage: <= power supply voltage

Permissible temporary current boost: 1.1 x In during 60 s (normal duty); 1.5 x In during 60 s (heavy duty)

Motor slip compensation: Not available in permanent magnet motor law; Automatic whatever the load; Can be suppressed; Adjustable

Acceleration and deceleration ramps: Linear adjustable separately from 0.01...9999 s; S, U or customized

Physical interface: Ethernet; 2-wire RS 485

Braking to standstill: By DC injection

Protection type: Thermal protection: motor; Safe torque off: motor; Motor phase break: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent between output phases and earth: drive; Overload of output voltage: drive; Short-circuit protection: drive; Motor phase break: drive; Overvoltages on the DC bus: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Line supply phase loss: drive; Overspeed: drive; Break on the control circuit: drive

Transmission rate: 10, 100 Mbits; 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps

Frequency resolution: Display unit: 0.1 Hz; Analog input: 0.012/50 Hz

Transmission frame: RTU

Electrical connection: Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16; Line side: screw terminal 25...50 mm²/AWG 4...AWG 1; Motor: screw terminal 25...50 mm²/AWG 4...AWG 1

Connector type: RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP; RJ45 (on the remote graphic terminal) for Modbus serial

Data format: 8 bits, configurable odd, even or no parity

Type of polarization: No impedance

Exchange mode: Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP

Number of addresses: 1…247 for Modbus serial

Method of access: Slave Modbus TCP

Supply: External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection; Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection

Local signalling: 3 LEDs for local diagnostic; 3 LEDs (dual colour) for embedded communication status; 4 LEDs (dual colour) for communication module status; 1 LED (red) for presence of voltage

Width: 331 mm

height: 630 mm

Depth: 297 mm

Net weight: 53 kg

analogue input number: 3

Analogue input type: AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits; AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits

Discrete input number: 8

Discrete input type: DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)

Input compatibility: DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2; DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2

Discrete input logic: Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)

analogue output number: 2

Analogue output type: Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits; Software-configurable current DQ-, DQ+: 30 V DC; Software-configurable current DQ-, DQ+: 100 mA

Sampling duration: 2 ms +/- 0.5 ms (DI1...DI4) - discrete input; 5 ms +/- 1 ms (DI5, DI6) - discrete input; 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input; 10 ms +/- 1 ms (AO1) - analog output

Accuracy: +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output

Linearity error: AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AO1, AO2: +/- 0.2 % for analog output

Relay output number: 3

Relay output type: Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles; Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles

Refresh time: Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)

Minimum switching current: Relay output R1, R2, R3: 5 mA at 24 V DC

Maximum switching current: Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC

Isolation: Between power and control terminals

maximum output frequency: 500 kHz

Maximum associated fuse rating: 100.0 A

Maximum input current: 55.6 A

IP degree of protection: IP21

Housing material: Sheet steel

Quantity per set: 1

enclosure mounting: Wall mounted

Environment

Insulation resistance: > 1 MOhm 500 V DC for 1 minute to earth

Noise level: 52 dB conforming to 86/188/EEC

Power dissipation in W: Natural convection: 202 W at 500 V, switching frequency 2.5 kHz; Forced convection: 700 W at 500 V, switching frequency 2.5 kHz

Volume of cooling air: 406 m3/h

Operating position: Vertical +/- 10 degree

Maximum THDI: <48 % with external line choke conforming to IEC 61000-3-12

Electromagnetic compatibility: Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

Pollution degree: 2 conforming to IEC 61800-5-1

Vibration resistance: 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6

Shock resistance: 15 gn for 11 ms conforming to IEC 60068-2-27

Relative humidity: 5…95 % without condensation conforming to IEC 60068-2-3

Ambient air temperature for operation: -15…50 °C (without derating); 50…60 °C (with derating factor)

Ambient air temperature for storage: -40…70 °C

Operating altitude: <= 1000 m without derating; 1000...4800 m with current derating 1 % per 100 m

Standards: UL 508C; IEC 61800-3; Environment 2 category C3 IEC 61800-3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1

product certifications: UL; TÜV; CSA

Marking: CE

NEMA degree of protection: NEMA 1

Standards: UL 508C; IEC 61800-3; EN/IEC 61800-3 environment 2 category C3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1

Overvoltage category: III

Regulation loop: Adjustable PID regulator

Noise level: 56 dB

Pollution degree: 2

ambient air temperature for operation: -15…60 °C

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 41.000 cm

Package 1 Width: 58.000 cm

Package 1 Length: 110.000 cm

Package 1 Weight: 52.427 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1706016EN

Circularity Profile: ENVEOLI1706016EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Upgradeability: Upgraded components available

© 2018 Alplan Kft.