Schneider-Electric
ATV340U07N4E
Tariff code: 8504409590
Link to the manufacturers site: ATV340U07N4E - variable speed drive - 0.75kW- 400V - 3 phases - ATV340 Ethernet
Main
Range of product: Altivar Machine ATV340
Product or component type: Variable speed drive
Product specific application: Machine
Design of frequency changer: U converter
Mounting mode: Cabinet mount
Variant: Standard version
communication port protocol: Modbus TCP; Modbus serial; EtherNet/IP
Network number of phases: 3 phases
Supply frequency: 50...60 Hz +/- 5 %
[Us] rated supply voltage: 380...480 V
[Us] rated supply voltage: 380...480 V - 15...10 %
Relative symmetric network frequency tolerance: 5 %
Nominal output current: 2.2 A
Relative symmetric mains voltage tolerance: 10 %
Number of input phases: 3
Number of output phases: 3
Motor power kW: 1.1 kW for normal duty; 0.75 kW for heavy duty
Motor power hp: 1.5 hp for normal duty; 1 hp for heavy duty
EMC filter: Class C3 EMC filter integrated
IP degree of protection: IP20
Complementary
Discrete input number: 5
Discrete input type: PTI programmable as pulse input: 0…30 kHz, 24 V DC (30 V); DI1...DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm; programmable
Discrete input logic: 16 preset speeds
Discrete output number: 2.0
Discrete output type: Programmable output DQ1, DQ2 30 V DC 100 mA
Analogue input number: 2
Analogue input type: AI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits; AI1 software-configurable temperature probe or water level sensor; AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Analogue output number: 1
Analogue output type: Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits
Relay output number: 2
Relay output type: Relay outputs R1A; Relay outputs R1C electrical durability 100000 cycles; Relay outputs R2A; Relay outputs R2C electrical durability 100000 cycles
Output voltage: <= power supply voltage
Number of inputs, bidirectional, not potential-free: 0
Number of inputs, potential-free: 0
Maximum switching current: Relay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC; Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC; Relay output R2C on resistive load, cos phi = 1: 5 A at 30 V DC; Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Minimum switching current: Relay output R1B: 5 mA at 24 V DC; Relay output R2C: 5 mA at 24 V DC
Encoder protocol: 1 Vpp; EnDat 2.2; Resolver; RS 422; SSI 24V; SSI 5V; TTL/HTL
Computer port: True
Optical interface present: False
Physical interface: 2-wire RS 485
Connector type: 3 RJ45
Method of access: Slave Modbus RTU; Slave Modbus TCP
Transmission rate: 4.8 kbit/s; 9.6 kbit/s; 19.2 kbit/s; 38.4 kbit/s
Transmission frame: RTU
Number of addresses: 1…247
Data format: 8 bits, configurable odd, even or no parity
Type of polarization: No impedance
Number of HW interfaces parallel: 0
Number of HW interfaces industrial Ethernet: 2
Number of HW interfaces PROFINET: 0
Number of HW interfaces serial RS232: 0
Number of HW interfaces serial RS422: 0
Number of HW interfaces serial RS485: 1
Number of HW interfaces serial TTY: 0
Number of HW interfaces USB: 0
Number of HW interfaces other: 0
Supporting protocol for AS-Interface Safety at Work: False
Supporting protocol for ASI: False
Supporting protocol for SUCONET: False
Supporting protocol for BACnet: False
Supporting protocol for CAN: False
Supporting protocol for Data-Highway: False
Supporting protocol for DeviceNet: False
Supporting protocol for DeviceNet Safety: False
Supporting protocol for EtherNet/IP: True
Supporting protocol for Foundation Fieldbus: False
Supporting protocol for INTERBUS: False
Supporting protocol for INTERBUS-Safety: False
Supporting protocol for KNX: False
Supporting protocol for LON: False
Supporting protocol for MODBUS: True
Supporting protocol for other bus systems: False
Supporting protocol for PROFIBUS: False
Supporting protocol for PROFINET CBA: False
Supporting protocol for PROFINET IO: False
Supporting protocol for PROFIsafe: False
Supporting protocol for SafetyBUS P: False
Supporting protocol for SERCOS: False
Supporting protocol for TCP/IP: True
4 quadrant operation possible: True
Asynchronous motor control profile: Constant torque standard; Variable torque standard; Optimized torque mode
Pollution degree: 2 conforming to IEC 61800-5-1
Synchronous motor control profile: Reluctance motor; Permanent magnet motor
Maximum output frequency: 0.599 kHz
Acceleration and deceleration ramps: S, U or customized; Linear adjustable separately from 0.01...9999 s
Motor slip compensation: Automatic whatever the load; Adjustable; Not available in permanent magnet motor law; Can be suppressed
Switching frequency: 2...16 kHz adjustable; 14...16 kHz with derating factor
Nominal switching frequency: 4 kHz
Speed drive output frequency: 0.1…599 Hz
Braking to standstill: By DC injection
Brake chopper integrated: True
Line current: 2.6 A at 380 V (normal duty); 2.1 A at 480 V (normal duty); 3.4 A at 380 V (heavy duty); 2.6 A at 480 V (heavy duty); 1.6 A at 480 V with external line choke (heavy duty); 3.4 A at 380 V without line choke (heavy duty)
Maximum associated fuse rating: 8.0 A
Maximum input current: 3.4 A
Maximum output voltage: 480 V
Nominal output power: 0.75 kW
Apparent power: 2.2 kVA at 480 V (normal duty); 2.2 kVA at 480 V (heavy duty)
Maximum transient current: 3.1 A during 60 s (normal duty); 3.3 A during 60 s (heavy duty); 3.8 A during 2 s (normal duty); 4 A during 2 s (heavy duty)
Electrical connection: Screw terminal, clamping capacity: 1.5...4 mm² for line side; Screw terminal, clamping capacity: 4...6 mm² for DC bus; Screw terminal, clamping capacity: 1.5...4 mm² for motor; Screw terminal, clamping capacity: 0.2...2.5 mm² for control
Capacity of DC link: 195.0 µF
Network frequency: 50...60 Hz
Prospective line Isc: 5 kA
1 phase low current possible: False
Base load current at high overload: 2.2 A
Base load current at low overload: 2.8 A
Application in domestic and commercial area permitted: False
Application in industrial area permitted: True
EMC limit value (complied): True
Power loss per device current dependent: 49.0 W
Power loss static current independent: 16.0 W
Power dissipation in W: Natural convection: 28 W at 380 V, switching frequency 4 kHz (heavy duty); Forced convection: 28 W at 380 V, switching frequency 4 kHz (heavy duty); Natural convection: 33 W at 380 V, switching frequency 4 kHz (normal duty); Forced convection: 33 W at 380 V, switching frequency 4 kHz (normal duty)
Housing material: Plastic
With safety function Safely Limited Speed (SLS): True
With safety function Safe brake management (SBC/SBT): True
With safety function Safe Operating Stop (SOS): False
With safety function Safe Position (SP): False
With safety function Safe programmable logic: False
With safety function Safe Speed Monitor (SSM): False
With safety function Safe Stop 1 (SS1): True
With sft fct Safe Stop 2 (SS2): False
With safety function Safe torque off (STO): True
With safety function Safely Limited Position (SLP): False
With safety function Safe Direction (SDI): False
Protection type: Thermal protection: motor; Safe torque off: motor; Motor phase loss: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent: drive; Output overcurrent between motor phase and earth: drive; Output overcurrent between motor phases: drive; Short-circuit between motor phase and earth: drive; Short-circuit between motor phases: drive; Motor phase loss: drive; DC Bus overvoltage: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Input supply loss: drive; Exceeding limit speed: drive; Break on the control circuit: drive
Operating element present: True
Width: 85.0 mm
Height: 270.0 mm
Depth: 232.5 mm
Net weight: 1.7 kg
Specific application: Machine
Motor starter type: Variable speed drive
Accuracy: +/- 0.6 % AI1, AI2 for a temperature variation 60 °C analog input; +/- 1 % AQ1 for a temperature variation 60 °C analog output
Connector type: connector(s)1 x RJ45, Modbus serial on front face; connector(s)1 x RJ45, Modbus serial for HMI on front face; connector(s)2 x RJ45, Ethernet IP/Modbus TCP on front face
Discrete input logic: Positive logic (source) (DI1...DI5), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (DI1...DI5), > 16 V (state 0), < 10 V (state 1); Positive logic (source) (PTI), < 0.6 V (state 0), > 2.5 V (state 1); Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
Exchange mode: Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Input compatibility: DI1...DI5: discrete input level 1 PLC conforming to IEC 61131-2; PTI: pulse input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2
Input/output type: Programmable as logic input/output DQ1: 0…1 kHz, <= 30 V DC, 100 mA; Programmable as logic input/output DQ2: 0…1 kHz, <= 30 V DC, 100 mA
Continuous output current: 2.2 A at 4 kHz for heavy duty; 2.8 A at 4 kHz for normal duty
Sampling duration: 2 ms +/- 0.5 ms (DI1...DI5) - discrete input; 5 ms +/- 1 ms (PTI) - pulse input; 1 ms +/- 1 ms (AI1, AI2) - analog input; 5 ms +/- 1 ms (AQ1) - analog output; 2 ms +/- 0.5 ms (DQ1, DQ2) - discrete input/output
Refresh time: Relay output (R1, R2): 5 ms (+/- 0.5 ms)
Safety function: STO (safe torque off) SIL 3
Vibration resistance: 1.5 mm peak to peak (f= 2…19 Hz) conforming to IEC 60721-3-3 class 3M3; 1 gn (f= 9…200 Hz) conforming to IEC 60721-3-3 class 3M3
Discrete and process manufacturing: Hoisting tower crane; Hoisting other application; Material handling grouping conveyor; Material handling palletizer - high performance; Material working (wood, ceramic, stone, pvc, metal) cutting - high accuracy; Material working (wood, ceramic, stone, pvc, metal) polishing; Material working (wood, ceramic, stone, pvc, metal) grinding; Material working (wood, ceramic, stone, pvc, metal) slitter; Packaging filling bottles - synchronized operation; Packaging feed conveyor - medium performance; Packaging grouping boxing; Packaging conveyor; Packaging elevator; Packaging other application; Hoisting standard crane - hoist; Material handling automatic storage / retrieval system; Packaging shrinking wrapping
[Ue] rated operational voltage: 380...480 V 1.1 kW normal duty; 380...480 V 0.75 kW heavy duty; 380...480 V 1.5 hp normal duty; 380...480 V 1 hp heavy duty
Environment
NEMA degree of protection: Not applicable
Operating altitude: <= 3000 m with current derating above 1000m
Operating position: Vertical +/- 10 degree
Product certifications: UL; CSA; TÜV; EAC; CTick
Marking: CE
Standards: IEC 61800-3; IEC 61800-5-1; IEC 60721-3; IEC 61508; IEC 13849-1; UL 618000-5-1; UL 508C
Assembly style: With heat sink
Electromagnetic compatibility: Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Environmental class (during operation): Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Environmental class (during storage): Class 1C3 according to EN 60721-3-1; Class 1S2 according to EN 60721-3-1
Environmental class (during transport): Class 2C3 according to EN 60721-3-2; Class 2S1 according to EN 60721-3-2
Maximum acceleration under shock impact (during operation): 70 m/s² at 22 ms
Maximum acceleration under shock load (during storage): 70 m/s² at 22 ms
Maximum acceleration under shock load (during transport): 70 m/s² at 22 ms
Maximum acceleration under vibratory load (during storage): 5 m/s² at 9...200 Hz
Maximum acceleration under vibratory load (during transport): 5 m/s² at 9...200 Hz
Maximum acceleration under vibrational stress (during operation): 5 m/s² at 9...200 Hz
Maximum deflection under vibratory load (during storage): 1.5 mm at 2...9 Hz
Maximum deflection under vibratory load (during transport): 1.5 mm at 2...9 Hz
Maximum deflection under vibratory load (during operation): 1.5 mm at 2...9 Hz
Permitted relative humidity (during operation): Class 3K5 according to EN 60721-3
Permitted relative humidity (during storage): Class 1K5 according to EN 60721-3
Permitted relative humidity (during transport): Class 2K5 according to EN 60721-3
Volume of cooling air: 18.0 m3/h
Type of cooling: Forced convection
Overvoltage category: Class III
Regulation loop: Adjustable PID regulator
Noise level: 52.7 dB
Pollution degree: 2
Ambient air transport temperature: -40…70 °C
Ambient air temperature for operation: -15…50 °C without derating (vertical position); 50…60 °C with derating factor (vertical position)
Ambient air temperature for operation: -15…60 °C
Ambient air temperature for storage: -40…70 °C
Power range: 0.55…1 kW at 380…440 V 3 phases; 0.55…1 kW at 480…500 V 3 phases
Isolation: Between power and control terminals
Insulation resistance: > 1 MOhm 500 V DC for 1 minute to earth
Linearity error: AI1, AI2: +/- 0.15 % of maximum value for analog input; AQ1: +/- 0.2 % for analog output
Shock resistance: 15 gn for 11 ms, class 3M3 conforming to IEC 60721-3-3
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 10.700 cm
Package 1 Width: 37.500 cm
Package 1 Length: 31.500 cm
Package 1 Weight: 2.485 kg
Unit Type of Package 2: P06
Number of Units in Package 2: 14
Package 2 Height: 75.000 cm
Package 2 Width: 60.000 cm
Package 2 Length: 80.000 cm
Package 2 Weight: 47.790 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.