Skip to main content

Schneider-Electric
ATV340D75N4E

variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet
Net discounted price 5,425.94 EUR
Available when ordered (delivery time: 78 working day(s))
Barcode: 3606480967139
Tariff code: 8504409590

Link to the manufacturers site: ATV340D75N4E - variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

Main

Range of product: Altivar Machine ATV340

Product or component type: Variable speed drive

Product specific application: Machine

Design of frequency changer: U converter

Mounting mode: Wall mount

Variant: Standard version

communication port protocol: Modbus serial; EtherNet/IP; Modbus TCP

Option card: Communication module, PROFINET; Communication module, DeviceNet; Communication module, CANopen; Communication module, EtherCAT

Network number of phases: 3 phases

Supply frequency: 50...60 Hz +/- 5 %

[Us] rated supply voltage: 380...480 V

[Us] rated supply voltage: 380...480 V - 15...10 %

Relative symmetric network frequency tolerance: 5 %

Nominal output current: 145.0 A

Relative symmetric mains voltage tolerance: 10 %

Number of input phases: 3

Number of output phases: 3

Motor power kW: 90 kW for normal duty; 75 kW for heavy duty

Motor power hp: 125 hp for normal duty; 100 hp for heavy duty

EMC filter: Class C3 EMC filter integrated

IP degree of protection: IP20

Degree of protection: UL type 1

Complementary

Discrete input number: 8

Discrete input type: PTI safe torque off: 0…30 kHz, 24 V DC (30 V); DI1...DI5 programmable as pulse input, 24 V DC (30 V), impedance: 3.5 kOhm; programmable

Discrete input logic: 16 preset speeds

Discrete output number: 1.0

Discrete output type: Programmable output DQ1, DQ2 30 V DC 100 mA

Analogue input number: 3

Analogue input type: AI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits; AI1 software-configurable temperature probe or water level sensor; AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits

Analogue output number: 2

Analogue output type: Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits

Relay output number: 3

Relay output type: Relay outputs R1A; Relay outputs R1C electrical durability 100000 cycles; Relay outputs R2A; Relay outputs R2C electrical durability 100000 cycles

Output voltage: <= power supply voltage

Number of inputs, bidirectional, not potential-free: 0

Number of inputs, potential-free: 0

Maximum switching current: Relay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC; Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC; Relay output R2C on resistive load, cos phi = 1: 5 A at 30 V DC; Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC

Minimum switching current: Relay output R1B: 5 mA at 24 V DC; Relay output R2C: 5 mA at 24 V DC

Encoder protocol: 1 Vpp; EnDat 2.2; Resolver; RS 422; SSI 24V; SSI 5V; TTL/HTL

Computer port: True

Optical interface present: False

Physical interface: 2-wire RS 485

Connector type: 3 RJ45

Method of access: Slave Modbus RTU; Slave Modbus TCP

Transmission rate: 4.8 kbit/s; 9.6 kbit/s; 19.2 kbit/s; 38.4 kbit/s

Transmission frame: RTU

Number of addresses: 1…247

Data format: 8 bits, configurable odd, even or no parity

Type of polarization: No impedance

Number of HW interfaces parallel: 0

Number of HW interfaces industrial Ethernet: 2

Number of HW interfaces PROFINET: 0

Number of HW interfaces serial RS232: 0

Number of HW interfaces serial RS422: 0

Number of HW interfaces serial RS485: 1

Number of HW interfaces serial TTY: 0

Number of HW interfaces USB: 0

Number of HW interfaces other: 0

Supporting protocol for AS-Interface Safety at Work: False

Supporting protocol for ASI: False

Supporting protocol for SUCONET: False

Supporting protocol for BACnet: False

Supporting protocol for CAN: False

Supporting protocol for Data-Highway: False

Supporting protocol for DeviceNet: False

Supporting protocol for DeviceNet Safety: False

Supporting protocol for EtherNet/IP: True

Supporting protocol for Foundation Fieldbus: False

Supporting protocol for INTERBUS: False

Supporting protocol for INTERBUS-Safety: False

Supporting protocol for KNX: False

Supporting protocol for LON: False

Supporting protocol for MODBUS: True

Supporting protocol for other bus systems: False

Supporting protocol for PROFIBUS: False

Supporting protocol for PROFINET CBA: False

Supporting protocol for PROFINET IO: False

Supporting protocol for PROFIsafe: False

Supporting protocol for SafetyBUS P: False

Supporting protocol for SERCOS: False

Supporting protocol for TCP/IP: True

4 quadrant operation possible: True

Asynchronous motor control profile: Variable torque standard; Constant torque standard; Optimized torque mode

Pollution degree: 2 conforming to IEC 61800-5-1

Synchronous motor control profile: Reluctance motor; Permanent magnet motor

Maximum output frequency: 0.599 kHz

Acceleration and deceleration ramps: S, U or customized; Linear adjustable separately from 0.01...9999 s

Motor slip compensation: Adjustable; Not available in permanent magnet motor law; Automatic whatever the load; Can be suppressed

Switching frequency: 1...8 kHz adjustable; 2.5...8 kHz with derating factor

Nominal switching frequency: 2.5 kHz

Speed drive output frequency: 0.1…599 Hz

Braking to standstill: By DC injection

Brake chopper integrated: True

Line current: 156.2 A at 380 V (normal duty); 135.8 A at 480 V (normal duty); 134.3 A at 380 V (heavy duty); 118.1 A at 480 V (heavy duty); 134.3 A; 118.1 A

Maximum associated fuse rating: 200.0 A

Maximum input current: 156.2 A

Maximum output voltage: 480 V

Nominal output power: 75.0 kW

Apparent power: 112.9 kVA at 480 V (normal duty); 98.2 kVA at 480 V (heavy duty)

Maximum transient current: 207.6 A during 60 s (normal duty); 217.5 A during 60 s (heavy duty); 207.6 A during 2 s (normal duty); 217.5 A during 2 s (heavy duty)

Electrical connection: Screw terminal, clamping capacity: 0.75...1.5 mm² for control; Screw terminal, clamping capacity: 120 mm² for line side; Screw terminal, clamping capacity: 95...120 mm² for DC bus; Screw terminal, clamping capacity: 120 mm² for motor

Capacity of DC link: 6800.0 µF

Network frequency: 50...60 Hz

Prospective line Isc: 50 kA

1 phase low current possible: False

Base load current at high overload: 145.0 A

Base load current at low overload: 173.0 A

Application in domestic and commercial area permitted: False

Application in industrial area permitted: True

EMC limit value (complied): True

Power loss per device current dependent: 1549.0 W

Power loss static current independent: 32.0 W

Power dissipation in W: Natural convection: 158 W at 380 V, switching frequency 4 kHz (heavy duty); Forced convection: 1359 W at 380 V, switching frequency 4 kHz (heavy duty); Natural convection: 180 W at 380 V, switching frequency 4 kHz (normal duty); Forced convection: 1585 W at 380 V, switching frequency 4 kHz (normal duty)

Housing material: Sheet steel

With safety function Safely Limited Speed (SLS): True

With safety function Safe brake management (SBC/SBT): True

With safety function Safe Operating Stop (SOS): False

With safety function Safe Position (SP): False

With safety function Safe programmable logic: False

With safety function Safe Speed Monitor (SSM): False

With safety function Safe Stop 1 (SS1): True

With sft fct Safe Stop 2 (SS2): False

With safety function Safe torque off (STO): True

With safety function Safely Limited Position (SLP): False

With safety function Safe Direction (SDI): False

Protection type: Thermal protection: motor; Safe torque off: motor; Motor phase loss: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent: drive; Output overcurrent between motor phase and earth: drive; Output overcurrent between motor phases: drive; Short-circuit between motor phase and earth: drive; Short-circuit between motor phases: drive; Motor phase loss: drive; DC Bus overvoltage: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Input supply loss: drive; Exceeding limit speed: drive; Break on the control circuit: drive

Operating element present: True

Width: 271.0 mm

Height: 908.0 mm

Depth: 309.0 mm

Net weight: 58.4 kg

Specific application: Machine

Motor starter type: Variable speed drive

Accuracy: +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output

Connector type: connector(s)1 x RJ45, Modbus serial on front face; connector(s)1 x RJ45, Modbus serial for HMI on front face; connector(s)2 x RJ45, Ethernet IP/Modbus TCP on front face

Discrete input logic: Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1); Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1); Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1)

Exchange mode: Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP

Input compatibility: STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2; DI1...DI8: discrete input level 1 PLC conforming to IEC 61131-2; DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68

Input/output type: Logic output DQ-: 0…1 kHz, <= 30 V DC, 100 mA; Logic output DQ+: 0…1 kHz, <= 30 V DC, 100 mA; Programmable as pulse output DQ+: 0…30 kHz, <= 30 V DC, 20 mA

Continuous output current: 173 A at 4 kHz for normal duty; 145 A at 4 kHz for heavy duty

Sampling duration: 2 ms +/- 0.5 ms (DI1...DI8) - discrete input; 5 ms +/- 1 ms (DI7, DI8) - pulse input; 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input; 5 ms +/- 1 ms (AQ1, AQ2) - analog output

Refresh time: Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)

Safety function: STO (safe torque off) SIL 3

Vibration resistance: 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6

Discrete and process manufacturing: Hoisting tower crane; Hoisting other application; Material handling grouping conveyor; Material handling palletizer - high performance; Material working (wood, ceramic, stone, pvc, metal) cutting - high accuracy; Material working (wood, ceramic, stone, pvc, metal) polishing; Material working (wood, ceramic, stone, pvc, metal) grinding; Material working (wood, ceramic, stone, pvc, metal) slitter; Packaging filling bottles - synchronized operation; Packaging feed conveyor - medium performance; Packaging grouping boxing; Packaging conveyor; Packaging elevator; Packaging other application; Hoisting standard crane - hoist; Material handling automatic storage / retrieval system; Packaging shrinking wrapping

[Ue] rated operational voltage: 380...480 V 90 kW normal duty; 380...480 V 75 kW heavy duty; 380...480 V 125 hp normal duty; 380...480 V 100 hp heavy duty

Environment

NEMA degree of protection: NEMA 1

Operating altitude: <= 4800 m with current derating above 1000m

Operating position: Vertical +/- 10 degree

Product certifications: UL; CSA; TÜV; EAC; CTick

Marking: CE

Standards: IEC 61800-3; IEC 61800-5-1; IEC 60721-3; IEC 61508; IEC 13849-1; UL 618000-5-1; UL 508C; IEC 61000-3-12

Maximum THDI: <48 % full load conforming to IEC 61000-3-12; <48 % 80 % load conforming to IEC 61000-3-12

Assembly style: With heat sink

Electromagnetic compatibility: Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

Environmental class (during operation): Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3

Environmental class (during storage): Class 1C3 according to EN 60721-3-1; Class 1S2 according to EN 60721-3-1

Environmental class (during transport): Class 2C3 according to EN 60721-3-2; Class 2S1 according to EN 60721-3-2

Maximum acceleration under shock impact (during operation): 150 m/s² at 11 ms

Maximum acceleration under shock load (during storage): 150 m/s² at 11 ms

Maximum acceleration under shock load (during transport): 150 m/s² at 11 ms

Maximum acceleration under vibratory load (during storage): 10 m/s² at 13...200 Hz

Maximum acceleration under vibratory load (during transport): 10 m/s² at 13...200 Hz

Maximum acceleration under vibrational stress (during operation): 10 m/s² at 13...200 Hz

Maximum deflection under vibratory load (during storage): 1.5 mm at 2...13 Hz

Maximum deflection under vibratory load (during transport): 1.5 mm at 2...13 Hz

Maximum deflection under vibratory load (during operation): 1.5 mm at 2...13 Hz

Permitted relative humidity (during operation): Class 3K5 according to EN 60721-3

Permitted relative humidity (during storage): Class 1K5 according to EN 60721-3

Permitted relative humidity (during transport): Class 2K5 according to EN 60721-3

Volume of cooling air: 295.0 m3/h

Type of cooling: Forced convection

Overvoltage category: Class III

Regulation loop: Adjustable PID regulator

Noise level: 69.9 dB

Pollution degree: 2

Ambient air transport temperature: -40…70 °C

Ambient air temperature for operation: -15…40 °C without derating (vertical position); 40…50 °C with derating factor (vertical position)

Ambient air temperature for operation: -15…50 °C

Ambient air temperature for storage: -40…70 °C

Power range: 55…100 kW at 380…440 V 3 phases; 55…100 kW at 480…500 V 3 phases

Isolation: Between power and control terminals

Insulation resistance: > 1 MOhm 500 V DC for 1 minute to earth

Linearity error: AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output

Shock resistance: 15 gn for 11 ms conforming to IEC 60068-2-27

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 59.000 cm

Package 1 Width: 110.000 cm

Package 1 Length: 43.000 cm

Package 1 Weight: 59.500 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1411014EN

Circularity Profile: ENVEOLI1411014EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.