Schneider-Electric
ATS48D75Q
Tariff code: 8537109899
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: ATS48D75Q - soft starter for asynchronous motor - ATS48 - 69 A - 230..415 V - 15..55 KW
Main
range of product: Altistart 48
product or component type: Soft starter
product destination: Asynchronous motors
product specific application: Heavy duty industry and pumps
device short name: ATS48
utilisation category: AC-53A
[Us] rated supply voltage: 230...415 V - 15...10 %
supply frequency: 50...60 Hz - 5...5 %
motor power kW: 55 kW at 400 V connection to the motor delta terminals for standard applications; 55 kW at 400 V connection to the motor delta terminals for severe applications; 15 kW at 230 V connection in the motor supply line for severe applications; 18.5 kW at 230 V connection in the motor supply line for standard applications; 30 kW at 230 V connection to the motor delta terminals for severe applications; 30 kW at 400 V connection in the motor supply line for severe applications; 37 kW at 230 V connection to the motor delta terminals for standard applications; 37 kW at 400 V connection in the motor supply line for standard applications
Complementary
device connection: To the motor delta terminals; In the motor supply line
protection type: Phase failure: line; Thermal protection: motor; Thermal protection: starter
standards: EN/IEC 60947-4-2
product certifications: DNV; GOST; UL; NOM 117; CCC; CSA; C-Tick; TCF; SEPRO
marking: CE
discrete input number: 5
discrete input type: PTC, 750 Ohm at 25 °C; (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
discrete input logic: Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
minimum switching current: 10 mA at 6 V DC for relay outputs
discrete output number: 2
discrete output type: (LO1) logic output 0 V common configurable; (LO2) logic output 0 V common configurable; (R1) relay outputs fault relay NO; (R2) relay outputs end of starting relay NO; (R3) relay outputs motor powered NO
analogue output type: Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
communication port protocol: Modbus
connector type: 1 RJ45
communication data link: Serial
physical interface: RS485 multidrop
transmission rate: 4800, 9600 or 19200 bps
function available: External bypass (optional)
operating position: Vertical +/- 10 degree
height: 290 mm
width: 190 mm
depth: 235 mm
net weight: 8.3 kg
assembly style: With heat sink
installed device: 31
network frequency: 47.5...63 Hz
noise level: 58 dB
output absolute accuracy precision: +/- 5 %
type of start: Start with torque control (current limited to 5 In)
motor starter type: Soft starter
discrete input voltage: 24 V <= 30 V
IcL starter rating: 75 A for connection in the motor supply line for severe applications; 75 A for connection in the motor supply line for standard applications; 130 A for connection to the motor delta terminals for severe applications; 130 A for connection to the motor delta terminals for standard applications
power dissipation in W: 201 W for severe applications; 245 W for standard applications
power range: 15…25 kW at 200…240 V 3 phases; 30…50 kW at 200…240 V 3 phases; 30…50 kW at 380…440 V 3 phases; 55…100 kW at 380…440 V 3 phases
supply inrush current: 0.4...1.3 Icl adjustable
Environment
electromagnetic compatibility: Conducted and radiated emissions level A conforming to IEC 60947-4-2; Conducted and radiated emissions level B conforming to IEC 60947-4-2; Damped oscillating waves level 3 conforming to IEC 61000-4-12; Electrostatic discharge level 3 conforming to IEC 61000-4-2; Immunity to electrical transients level 4 conforming to IEC 61000-4-4; Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3; Voltage/current impulse level 3 conforming to IEC 61000-4-5
relative humidity: 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
ambient air temperature for operation: 40…60 °C (with current derating of 2 % per °C); -10…40 °C (without derating)
ambient air temperature for storage: -25…70 °C
operating altitude: <= 1000 m without derating; > 1000...2000 m with current derating of 2.2 % per additional 100 m
Packing Units
Number of Units in Package 1: 1
Number of Units in Package 2: 2
Package 1 Height: 36 cm
Package 1 Length: 39 cm
Package 1 Weight: 10.266 kg
Package 1 Width: 30.5 cm
Package 2 Height: 73.5 cm
Package 2 Length: 60 cm
Package 2 Weight: 33.532 kg
Package 2 Width: 80 cm
Unit Type of Package 1: PCE
Unit Type of Package 2: P06
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: X
Environmental Disclosure: ENVPEP111031EN
Circularity Profile: ENVEOLI111007EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.