Skip to main content

Schneider-Electric
9007C52B2Y1901

9007C compact limit switch - 1 NO/NC - rotary head - CW+CCW - standard
Barcode:
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: 9007C52B2Y1901 - 9007C compact limit switch - 1 NO/NC - rotary head - CW+CCW - standard

Main

range of product: 9007

series name: Heavy duty

product or component type: Limit switch

product specific application: Compact box

device short name: 9007C

body type: Plug-in

head type: Rotary head

material: Metal

fixing mode: By the body

movement of operating head: Rotary

type of operator: Zinc spring return without operating lever (-)9007C lever

switch actuation: From left and right; CW and CCW

type of approach: Lateral approach, 1 or 2 programmable direction

electrical connection: Male connector, connector type: 7/8" - 16 UN - 2 A mini connector, 5 pins

number of poles: 1

contacts type and composition: NC-NO

contact operation: Snap action

positive opening: Without

sale per indivisible quantity: 1

Complementary

body material: Zinc

head material: Zinc

function available: -

switch function: SPDT-DB

contact form: Form Z

contacts material: Silver contacts

terminals description ISO n°1: (1-2)NC; (3-4)NO

minimum torque for tripping: 0.45 N.m

maximum actuation speed: 90 ft/min with 45° cam angle, levers only; 130 ft/min with 30° cam angle, levers only

tripping angle: 10 °

maximum displacement angle: 90 °

repeat accuracy: +/- 0.002 in linear travel of cam

[Ie] rated operational current: 0.55 A at 120 V DC; 3 A at 240 V AC; 6 A at 120 V AC; 0.27 A at 240 V DC

[Ithe] conventional enclosed thermal current: 6 A

[Ui] rated insulation voltage: 600 V (pollution degree 3) conforming to UL 508 for contact block; 600 V (pollution degree 3) conforming to CSA C22.2 No 14 for contact block

[Uimp] rated impulse withstand voltage: 2.5 kV AC 1 min conforming to CE; 2.2 kV AC 1 min conforming to UL; 2.64 kV AC 1 s conforming to CSA

short-circuit protection: 10 A by CC fuse, protection type: non-time delay

electrical durability: 1000000 cycles

local signalling: without

mechanical durability: 10000000 cycles

width: 39.37 mm

height: 79.76 mm

depth: 63.50 mm

net weight: 0.57 kg

compatibility code: 9007C

Environment

shock resistance: 60 gn for 9 ms conforming to IEC 60068-2-27

vibration resistance: 25 gn (f= 10…150 Hz) conforming to IEC 60068-2-6

NEMA degree of protection: NEMA 1 conforming to Nema type 250; NEMA 2 conforming to Nema type 250; NEMA 4 conforming to Nema type 250; NEMA 6 conforming to Nema type 250; NEMA 6P conforming to Nema type 250; NEMA 12 conforming to Nema type 250; NEMA 13 conforming to Nema type 250

IP degree of protection: IP67 conforming to IEC 60529

electrical shock protection class: Class 0 conforming to IEC 61140

ambient air temperature for operation: -29…85 °C for standard environment

ambient air temperature for storage: -29…85 °C

environmental characteristic: Standard environment

protective treatment: Epoxy powder coat

Offer Sustainability

EU RoHS Directive: Not applicable, out of EU RoHS legal scope