Skip to main content

Schneider-Electric
56507

residual current protection relay, Vigirex RH197P, 30 mA to 30 A, 220 VAC to 240 VAC 50/60 Hz
Net discounted price 216.03 EUR
Available when ordered (delivery time: 8 working day(s))
Barcode: 3303430565079
Tariff code: 8536490099

Link to the manufacturers site: 56507 - residual current protection relay, Vigirex RH197P, 30 mA to 30 A, 220 VAC to 240 VAC 50/60 Hz

Main

Range: VigiPacT

Device short name: RH197P

Product or component type: Residual current protection relay

Relay application: Protection relay

mounting support: Front panel

Earth-leakage protection class: Type A

Type of setting: Selector

Residual earth-leakage sensitity adjustment type: Adjustable 19 settings

Earth leakage current: 0.03…30 A

Residual earth-leakage time delay adjustment type: Instantaneous for 0.03 A; Adjustable 7 settings 0…4.5 s for 0.03…30 A

alarm threshold: 50 %

Range compatibility: VigiPacT TOA earth leakage current sensor; VigiPacT A earth leakage current sensor; VigiPacT L earth leakage current sensor

[Ithe] conventional enclosed thermal current: 8 A

Minimum load: 10 mA at 12 V

[Us] rated supply voltage: 220...240 V AC 50/60 Hz 70...110 %

Power consumption in VA: 4 VA

Network rated voltage: 1000 V - AC at 50/60 Hz (maximum) ; 1000 V - AC at 400 Hz (maximum)

Earthing system: IT; TT; TN-S

[Uimp] rated impulse withstand voltage: 8 kV

Reset: Manual reset; Automatic reset

Complementary

Test function: Local; Remote test

Monitoring: Electronics (watchdog) ; Power supply (continuous) ; Relay/sensor link (continuous)

Signal contacts composition: 1 NO

Type of measurement: Earth fault current internal measurement, range: 80...100 %

Refresh time: 0.5 s

Tamperproof of settings: Protected by sealable cover

Connections - terminals: Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12; Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12; Auxiliary power supply: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12; Fault: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12; Fault: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12; Fault: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12; Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12; Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12; Relay test and fault reset: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12; Sensor: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12; Sensor: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12; Sensor: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12; Voltage presence: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12; Voltage presence: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12; Voltage presence: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12

Wire stripping length: Auxiliary power supply: 7 mm; Fault: 7 mm; Relay test and fault reset: 7 mm; Sensor: 7 mm; Voltage presence: 7 mm

Tightening torque: Auxiliary power supply: 0.6 N.m; Fault: 0.6 N.m; Relay test and fault reset: 0.6 N.m; Sensor: 0.6 N.m; Voltage presence: 0.6 N.m

Standards: EN/IEC 60947-2 Annex M; EN/IEC 60755; UL 1053; CAN/CSA C22.2 No. 144

Width: 72 mm

height: 72 mm

Depth: 92 mm

Cut-out dimensions: 68 x 68 mm

Net weight: 0.3 kg

IP degree of protection: IP40 on front face: conforming to EN/IEC 60529; IP30 on side parts: conforming to EN/IEC 60529; IP20 on connection terminals: conforming to EN/IEC 60529

IK degree of protection: IK07 conforming to EN 50102

Mechanical robustness: Fire resistance conforming to IEC 60695-2-1; IK protection 2 joules: IK07 conforming to EN 50102; Vibrations 13.2...100 Hz: 0.7 g; Vibrations 2...13.2 Hz: +/- 1 mm

Compatibility code: RH197P

Environment

Overvoltage category: IV

Electrical shock protection class: Class II

Electromagnetic compatibility: Conducted and radiated emissions: , B, conforming to CISPR 11; Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6; Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2; High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5; Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4; Radiated susceptibility: , 3, conforming to IEC 61000-4-3

Relative humidity: 95 % at 55 °C

Pollution degree: 3 conforming to IEC 60664-1

ambient air temperature for operation: -25…55 °C

Ambient air temperature for storage: -40…85 °C

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 10.5 cm

Package 1 Width: 8.5 cm

Package 1 Length: 9.0 cm

Package 1 Weight: 336.0 g

Unit Type of Package 2: S03

Number of Units in Package 2: 24

Package 2 Height: 30.0 cm

Package 2 Width: 30.0 cm

Package 2 Length: 40.0 cm

Package 2 Weight: 8.551 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant with Exemptions

Mercury free: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP2310023EN

Circularity Profile: ENVEOLI2310023EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.