Skip to main content

Schneider-Electric
56163

Earth-leakage relay RH21M - 300 mA - 0.06 s - 240 V
Net discounted price 138.96 EUR
Available when ordered (delivery time: 22 working day(s))
Barcode: 3303430561637
Tariff code: 8536490099

Link to the manufacturers site: 56163 - Earth-leakage relay RH21M - 300 mA - 0.06 s - 240 V

Main

Range: VigiPacT

Device short name: RH21M

Product or component type: Residual current protection relay

Relay application: Protection relay

mounting support: DIN rail

Earth-leakage protection class: Type A

Type of setting: Selector

Residual earth-leakage sensitity adjustment type: Adjustable 2 settings

Earth leakage current: 0.03 A; 0.3 A

Residual earth-leakage time delay adjustment type: Instantaneous for 0.03 A; Instantaneous for 0.3 A; Fixed 0.06 s for 0.3 A

Range compatibility: VigiPacT TOA earth leakage current sensor; VigiPacT A earth leakage current sensor; VigiPacT L earth leakage current sensor

[Ithe] conventional enclosed thermal current: 8 A

Minimum load: 10 mA at 12 V

[Us] rated supply voltage: 220...240 V AC 50/60 Hz 55...110 %

Power consumption in VA: 4 VA

Network rated voltage: 1000 V - AC at 50/60 Hz (maximum) ; 1000 V - AC at 400 Hz (maximum)

Earthing system: IT; TT; TN-S

[Uimp] rated impulse withstand voltage: 8 kV

Reset: Manual reset

Complementary

Test function: Local; Remote test

Monitoring: Electronics (continuous) ; Power supply (continuous) ; Relay/sensor link (continuous)

Type of measurement: Earth fault current internal measurement, range: 80...100 %

Tamperproof of settings: Protected by sealable cover

Connections - terminals: Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12; Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12; Auxiliary power supply: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12; Fault: screw terminal cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12; Fault: screw terminal cable(s) 0.2…4 mm² rigid AWG 24...AWG 12; Fault: screw terminal cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12; Relay test and fault reset: screw terminal cable(s) 0.14…1 mm² flexible AWG 26...AWG 16; Relay test and fault reset: screw terminal cable(s) 0.14…1.5 mm² rigid AWG 26...AWG 16; Relay test and fault reset: screw terminal cable(s) 0.25…0.5 mm² flexible AWG 26...AWG 16; Sensor: screw terminal cable(s) 0.14…1 mm² flexible AWG 26...AWG 16; Sensor: screw terminal cable(s) 0.14…1.5 mm² rigid AWG 26...AWG 16; Sensor: screw terminal cable(s) 0.25…0.5 mm² flexible AWG 26...AWG 16; Voltage presence: screw terminal cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12; Voltage presence: screw terminal cable(s) 0.2…4 mm² rigid AWG 24...AWG 12; Voltage presence: screw terminal cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12

Wire stripping length: Auxiliary power supply: 7 mm for top connection; Fault: 8 mm for bottom connection; Relay test and fault reset: 5 mm for bottom connection; Sensor: 5 mm for top connection; Voltage presence: 8 mm for bottom connection

Tightening torque: Auxiliary power supply: 0.6 N.m top; Fault: 0.6 N.m bottom; Relay test and fault reset: 0.25 N.m bottom; Sensor: 0.25 N.m top; Voltage presence: 0.6 N.m bottom

9 mm pitches: 6

Standards: EN/IEC 60947-2 Annex M; EN/IEC 60755; UL 1053; CAN/CSA C22.2 No. 144

Width: 54 mm

height: 81 mm

Depth: 74 mm

Net weight: 0.3 kg

IP degree of protection: IP40 on front face: conforming to EN/IEC 60529; IP30 on side parts: conforming to EN/IEC 60529; IP20 on connection terminals: conforming to EN/IEC 60529

IK degree of protection: IK07 conforming to EN 50102

Mechanical robustness: Fire resistance conforming to IEC 60695-2-1; IK protection 2 joules: IK07 conforming to EN 50102; Vibrations 13.2...100 Hz: 0.7 g; Vibrations 2...13.2 Hz: +/- 1 mm

Compatibility code: RH21M

Environment

Overvoltage category: IV

Electrical shock protection class: Class II

Electromagnetic compatibility: Conducted and radiated emissions: , B, conforming to CISPR 11; Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6; Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2; High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5; Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4; Radiated susceptibility: , 3, conforming to IEC 61000-4-3

Relative humidity: 95 % at 55 °C

Pollution degree: 3 conforming to IEC 60664-1

ambient air temperature for operation: -35…70 °C

Ambient air temperature for storage: -55…85 °C

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 8.8 cm

Package 1 Width: 7.8 cm

Package 1 Length: 9.3 cm

Package 1 Weight: 311.0 g

Unit Type of Package 2: S03

Number of Units in Package 2: 36

Package 2 Height: 30.0 cm

Package 2 Width: 30.0 cm

Package 2 Length: 40.0 cm

Package 2 Weight: 11.683 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant with Exemptions

Mercury free: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP2310022EN

Circularity Profile: ENVEOLI2310022EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free: Yes

© 2018 Alplan Kft.